Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - installation of additional 40mva transformer strengthening of 33kv main bus with twin moose conductor at 132kv substation gosasinghpur under etd sultanpur; substation, s..
Tender For corrigendum : erection of 01 nos 33kv rewan bay with supply of material, integration and remote gateway work at 220kv ss bangra under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : erection of 01 nos 33 kv birdha bay with supply of material, integration and remote gateway work at 220kv ss birdha under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - installation of additional 63mva transformer along with strengthening of 132kv main bus with twin moose conductor at 132/33kv s/s gauriganj (amethi) under etd-sultanpur;..
Tender For corrigendum : supply of materials for maintenance work at 132kv sub station ghatampur under etd-ii kanpur - jaw assembly suitable for 36kv isolator, rating 2000a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., daw assembly suitable for 36kv isolatorrating 1250a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin zebra conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., 132kv special type isolator bi-matellic terminal connector (dropper/runthrough type) 50mm dia. and moose conductor as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin pantherconductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin zebra conductor made of aluminium alloy. with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin pantherconductor made of aluminium alloy. with galv. nut & bolts. as per sample without holes., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin pantherconductor made of lm-6 aluminium alloy with gal. nut & bolts., multipurpose cleaner dc 2-26 spray type 400ml pack of standard make., 400 watt hpsv ballast suitable for high mast light fitting., termminal connector for 132kv pt suitable for pantherconductor made of all alloy lm-06 completer with nut-bolt and washer as per sample., indication led ryb (24-110v) ac/dc standerd make suitable for control panle., silica gel 6-12mm granules of blue colour, sealed pack packing., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin zebra conductor made of lm-6 aluminium alloy with gal. nut & bolts., nut bolt with washer size 10x50 mm (gi), nut bolt with washer size 12x50 mm (gi), nut bolt with washer size 10x65 mm (gi), nut bolt with washer size 12x65 mm (gi), terminal connector lm-06 all. alloy suitable for 132kv ct heptacare make other end twin pantherconductor with gi nut & bolt as per sample., terminal connector made of lm-6 alloy suitable for 33 kv g.nandy make solator jaw plate and other end twin pantherconductor with galv. nut, bolts & washer as per sample., cb clamp 145 kv suitable for pantherconductor with galv. nut & bolts., supply of female contact for 145kv rama make isolator as per sample., supply of male contact for 145kv rama make isolator as per sample.
Tender For providing fencing arrangements, retaining wall, stringing and tensioning of 3nos twin moose acsrconductor from loc.27 to gantry and other miscellenous civil works for the 400 kv oh - ug conversion gantry for the sc line of 400 kv ottiyambakkam to taramani feeder is located adjacent to perumbakkam 110kv ss.
Tender For corrigendum : tender description : design, engineering, supply, erection, testing and commissioning of work towards construction of 400kv indravati to therubali double circuit transmission line from proposed 600mw, psp sub station at mukhiguda to proposed 400/220kv gss therubali with twin acsr moose conductor and towers suitable for quad moose configuration line length 93.25 kms approx. in the state of odisha, on epc contract basis.
Tender For tender for supply of connector clamp for 245 kv isolator suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy grade lm6 lm25 ec grade aluminium. casting shall be smooth homogeneous and free from cracks , blow holes and other casting defects , connector clamp for 245 kv ct suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design , connector clamp for 145 kv current transformer suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp shall have adequate mechanical strength and low contact resistance as per relevant is iec standards , pg clamp suitable for zebra to zebra conductor 4 bolted type complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy with smooth finish and defect free casting , gi perforted cable tray 225 and 250 mm , gi perforted cable tray 75 mm , pg clamp suitable for pather to pather conductor 3 bolted type complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy with smooth finish and defect free casting , twin connector clamp for 33 kv ct suitable for twin moose conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design , connector clamp for 145 kv cb suitable for pantherconductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design , copper bar rectangular half hard size 75x10 mm , connector clamp for 36 kv cb suitable for twin pantherconductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design , male contact jaw of 132 kv g nandi make isolator made of copper with nuts bolt and washer as per sample , female contact jaw of 220 kv g nandi make isolator made of copper with nuts bolt and washer as per sample
Tender For providing of custom bid for services - 400053851 acsr moose conductor re-winding work of 400 kv double circuit acsr moose transmission line between brbcl to npgcl,ntpc nabinagar