Get complete information related to latest Acsr Weasel Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acsr Weasel Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acsr Weasel Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

CTN :45713010 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of sitc control panel 2 loops , sitc control panel 4 loops , sitc of network module the module shall connect panels , sitc of active repeater panel to be integrated with fire alarm , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitcof addressable multi sensor with co detection , sitcc of response indicator on surface or recessed , sitc of short circuit isolator module base with all mounting , sitc of analogue addressable dual action , sitc of addressable horn with a maximum output of up to 100 db a , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls , complete earthing electrode and excavation etc , earth continuity conductor , false ceiling board and cross tee , butterfly valves (v2) as per is 13095 (q2) * /bid number : gem/2026/b/7624747 + /dated: 27-06-2026 ' ' / bid document 1 / 20

CTN :45713123 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of sitc control panel 2 loops , sitc control panel 4 loops , sitc of network module the module shall connect panels , sitc of active repeater panel to be integrated with fire alarm , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitcof addressable multi sensor with co detection , sitcc of response indicator on surface or recessed , sitc of short circuit isolator module base with all mounting , sitc of analogue addressable dual action , sitc of addressable horn with a maximum output of up to 100 db a , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls , complete earthing electrode and excavation etc , earth continuity conductor , false ceiling board and cross tee , butterfly valves (v2) as per is 13095 (q2) * /bid number : gem/2026/b/7624664 + /dated: 27-06-2026 ' ' / bid document 1 / 25

CTN :45690757 Due date: 02 Jul, 202602 Jul, 2026 5.78 Lacs
Tender For a.r. & maintenance of 196 hmps flats at south avenue under sub div-1 of ded-201, new delhi. (sh: replacement of defective electrical accessories i/c supply of material).subwork/packages:replacement of defective electrical accessories i/c supply of material. - supplying, installation, testing & commissioning of flood light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage : input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range - 5 deg. to 50 deg. centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%, thd < 10% as per iec 61000-3-2, p. f.≥0.95, ip-66, ik-10, cri >70, under voltage and over voltage protection, emiemc as per cispr -15, lenses for beam angle 30 deg- 120 deg as per the application and the project requirement deg., suitable tilt able fitting, life time (led, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000°k/4000°k /5700°k /6500°k (as per ansi bin), sdcm(standard deviation color matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 <120 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). (make: havells/ wipro/ philips/ crompton/ regent) 1.1 50 watt , 1.5 sq mm frls pvc insulated single core copper conductor cable., , 4 sq mm frls pvc insulated single core copper conductor cable., , 6 sq mm frls pvc insulated single core copper conductor cable., , s.p. 5/6 a, one way modular switch, , s.p. 5/6 a, two way modular switch, , s.p. 15/16 a, one way modular switch, , 3 pin 5/6 a modular socket outlet, , 6 pin 15/16 a modular socket outlet, , modular bell push, , stepped type modular fan regulator (2 module), , telephone socket outlet modular type, , t.v. socket outlet modular type, , modular blanking plate, , modular base & cover plate for 1 or 2 module, , modular base & cover plate for 3 module, modular base & cover plate for 4 module, , modular base & cover plate for 6 module, , modular base & cover plate for 8 module, , modular base & cover plate for 12 module, , modular gi box for 2 module, , modular gi box for 3 module, , modular gi box for 4 module, , modular gi box for 6 module, , modular gi box for 8 module, , modular gi box for 12 module, , 3 pole mccb, 125 a, 16ka, , 6 amps. to 32 amps. ratings, sp mcb, "c" curve, 10 ka breaking capacity, , 40 amps., 2 pole isolator, , 63 amps., 2 pole isolator, , 100amp., 4 pole isolator, , supply of led batten light (system lumen efficacy ≥105 <120 lm/watt) of following body materials. powder coated die cast /extruded aluminium body (thickness > 1.20 mm) (make: havells/ wipro/ philips/crompton/regent), , 18-22 watt, , 40 watt, , supply of led down lighter (smd type) (system lumen efficacy ≥ 105 <120 lm/watt) of following body materials. powder coated die cast/extruded aluminium body including trim with aluminium reflector (make: havells/ wipro/ philips/ crompton/regent), , 5-7 watt, , 8-10 watt, , 12-15 watt, , supply of led bulb 9 watt b-22/e- 27 type (3 star & above) (white/yellow colour) (make: havells/ wipro/ philips/ crompton/regent), , less credit for damaged and dismantled material received from the work :-, , 5/15/16 amp. switch/socket/bell push/tv antenna socket/telephone socket/dp switch/fan regulator (assorted), , pvc

State Government

CTN :45694609 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of high dielectric strength and thermal stability sf 6 gas , mccb 3 pole 100a 3ph 415v of standard make , rotary head assembly for smc make isolator , jumper cone for panther conductor , vibration damper for earth wire 7 3.25 mm , single tension fitting for acsr panther , pg clamp panther to panther conductor , ct shorting strip for 36kv ct made of copper , 145kv isolator blade smc make , spring charging motor suitable for 145kv cgl make sf6 cb , 145kv isolator clamp suitable for genandy make for panther conductor , tripping coil for 245kv sf6 circuit breaker

Trust

CTN :45679919 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of miscellaneous electric items - steel tubular 9 mtr. long pole (st-410 sp33) , acsr weasel conductor 6/1/2.59 mm , 11 kv go, ab switch 3-phase, 3-pole, 200 amp vertical type with rod heavy duty , back clamp for 9 mtr. pole with fitting , 11 kv horn gap fuse set (hg set) 3-phase 400 amp polymer type heavy duty , la set station type (gapless surge arrestor, 9kv, 10 ka, la with polymer housing station type heavy duty) , xlpe pvc cable single core 300 mm sqr. (300 sq mm cable 1.1 kv grade, pvc insulated standard conductor frls type) , 11 kv polymeric pin insulator 12 kv, 5 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm , insulator disk 11 kv (11kv polymeric composite discs insulator with pin and gl fittings, 12 kv, mainfalling load 45 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm) , channel 100.00 mm x 50.00 mm x 5.00 mm (10 feet long) , nut bolt full thread with washer 4"/6" heavy duty , wedge connection / pg clamps , danger plate and clamps , g.i. bracket wire for anti climbing , 3 phase 4 wire trivector meter with ct/pt unit , aluminium thimble 185 mm , lv distribution box for 400 kva dtr with mccb for incomer & sfu's for outgoing circuits , stay set (gi rod with clamp) - galvanised stay set with 50x8mm stay clamp, gav. insulator (02 nos.) anchor plate (200x200x6mm) nut-bolt 2 nos. turn-buckles, 1.8 m long 16 mm diameter solid g5 stay rod & 7/3. 15 mm dia gi standard wire complete , g.i. guy rod complete with clamp and insulator , anti climbing device with clamp , guy / stay wire 7/14, galvanized steel, typically hot-dip zinc-coated for corrosion resistance , giv cross-arm with top bracket and gi channel-arm including clamp (gi v cross arm with top bracket including clamp and gl channel x-arm including clamps and braces) , channel 75 x 75 x 6mm (10 feet long) , g.i. earthing wire 8/10 mm

CTN :45662043 Due date: 07 Jul, 202607 Jul, 2026 44.41 Lacs
Tender For running contract for deposit works under edd-jaisinghpur, sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., pg clamp, guarding angle clamp., barbed wire g.i., stay loop insulator/guy insulator., bolts, nuts & washers all sizes., l.t. connector (pearcing)., gi pipe 6" dia, hdpe pipe 120mm., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 09 mtr. long., safe carriage of stp 11 mtr. long., safe carriage of pcc pole 8.5 mtr. long., safe carriage of pcc pole 09 mtr. long., safe carriage of pcc pole 11 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of acsr rabbit conductor., safe carriage of 11 kv xlpe cable al. 3x70/3x120/3x185/3x240 sq.mm., safe carriage of lt abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 10/16/25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp 09 mtr. long from site to pit point., dragging of stp 11 mtr. from site to pit point., dragging of pcc pole 8.5 mtr. from site to pit point., dragging of pcc pole 09 mtr. from site to pit point., dragging of pcc pole 11 mtr. from site to pit point., fabrication & erection of single pole support on st pole 09 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of single pole support on st pole 11 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of single pole support on pcc pole 8.5 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of double pole support on pcc pole 8.5 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of single pole support on pcc pole 09 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of double pole support on pcc pole 09 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of single pole support on pcc pole 11 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., fabrication & erection of double pole support on pcc pole 11 mtr. including digging of pit & fixing of all accessories and clamps including grouting & earthing of pole as per respo norms., stay complete with concreating as per respo norms., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc as per respo norms., laying stringing & sagging of new acsr rabbit conductor including binding jumpering etc as per respo norms., digging of trench & laying of cable 11 kv xlpe cable 3x70/3x120/3x185/3x240 sq.mm including sands & brick as per respo norms., laying of cable with hdd method using with hdpe pipe (120mm od pn-4 pe 80 grade uv stabilized hdpe pipe as per is: 4984 of 6 metre) 11 kv xlpe cable 3x70/3x120/3x185/3x240 sq.mm as per respo norms., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x70/3x120/3x185/3x240 sq.mm xlpe 11 kv cable (cost