Web Analytics Made Easy - StatCounter

Addressable Manual Call Point Tenders

Get complete information related to latest Addressable Manual Call Point Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Addressable Manual Call Point Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Addressable Manual Call Point Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45199569 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For supply of spares for ht & lt system, flood, drainage and dewatering sump", - closing coil 110vdc (for 11kv hwx vcb), tripping coil 110v dc (for 11 kv hwx vcb), agni motors bangalore-, 91type:sg301s1 v: 220ac/dc w:150 a:1.6 rpm: 100 i.cl: f duty: s2-5 min, vaccum interrupter (vg2, for 11kv hwx vcb), epoxy body (for 11kv hwx vcb), 11kv hwx mechanism. with (110v dc coil & 230 v motor), 11kv gang operated (go) switch, 11kv 120 mm². straight through jointing kit., 11kv 120 mm² termination kit, 11kv 240 mm². straight through jointing kit., 11kv 240 mm². termination kit., hdz-70-401, she 48.131.370-05 s2:8 5, ac230-240v 50-60hz 380 w, 5000r/min 6.0 a,, closing coil (110v dc, hvx-o, 33kv vcb), tripping coil (110v dc, hvx-0, 33kv vcb), service & test position limit switchs, (hvx-0, 33kv vcb), camp, disc complete (hvx-0, 33kv vcb), spring charging drum assembly ((hvx-0, 33kv vcb), rack-in & rack-out screws (hvx-0,33 kv vcb), 33kv gang operated (go) switch, 33kv 240 sq mm. straight through jointing kit., 33kv 240 mm². termination kit., single phase surge arrest, 9kv, 10kv, float switch (level sensor) with cable, mounting screw and termanal box 16(8) a 250 v, t-80, pressure gauege 0-16 kg/cm³ en-837-1, power contactor mo 250, 250a, 3p, 240v ac coil, aux 2no+2nc contacts, mccb, with magnetic release mccb, with magnetic release dsine dn3-630m 630a, 3p 50ka, 415vc,, power contractor mnx250 250a, 3p, 240vac coil, aux 2no+2nc contacts, power contractor with 240vac coil mnx650 650a, 3p, 240vac coil, aux 2no+2nc contacts., power contractor with 240vac coil mnx300 300a, 3p, 240vac aux 2no+2nc contacts, power contractor with 240vac coil, mo110, 110a, 3p, power contractor with 240vac coil, aux 2no+2nc contacts, rto-4, 72-110a bimetal overload relay, direct mounting (class 10), 1no+1nc auxiliary contacts with build in spp (single phasing protection), bimetal overload relay mn12 135-255a bimetal overload relay, direct mounting (class 10), 1no+1nc auxiliary contacts with build in spp (single phasing protection), bimetal overload relay mn12 180-300a bimetal overload relay, direct mounting (class 10), 1no+1nc auxiliary contacts with build in spp(single phasing protection), 6a control fuse link 415v ac, type: pq8n ch2j 1myn563613-ead tripping relay (86) flush mounting, case size 1/2, contacts 4no+3nc hr with hr flag aux volt 220 v dc, tripping coil, mo1 220-250v dc/ac, eq96 moving iron ammeter: range: 0-500a 500/1a, 250/1a, 50hz., thermostat bater cord 20-17 15a, 250v, 50hz., relay cr-m220vdc 4 1svr405613r9000, panel door handle 11kv, station auxilliary board dyear), mccb operating handle ohg45h9k handle, shunt open. release, 220/240v e1/6-t8, led panel light om-x, 3/5w/230v, omega, omo 10 33kj o resistor 33k/10w, 5%-with bakelite, power pack with battery backup input: 230vac, output: 220v dc, 0.5a, fuse 3a, slow blow for power pack, supply:230vac, 24vdc,, electronic magnetic flow meter line size: 200nb output:4-20ma, 2-7000lpm, max.w. p: 16kg/cm³, alarm range: 0-

CTN :45141853 Due date: 01 Jun, 202601 Jun, 2026 7.20 Lacs
Tender For procurement of spares for autronica make fire detection and alarm system installed at stpp, jaipur, mancherial, telangana

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

CTN :45072255 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges

CTN :45076727 Due date: 14 May, 202614 May, 2026 NA
Tender For tender for supply of spares for fire detection and protection system - interfacing module for hooter (siga-cc1 , photo electric type smoke detectors ( si , manual pull stations (siga-278 ) , alarm buzzer (hooter )-g1rf-hd , monitor module ( 1 input module ) (siga- , electronic modules of all types , detector base (siga-sb ) , multisensor type detector (siga-phs) , detector base (siga-ib ) , hooter , g1rf-hdvm - genesis horn-strobe , false celling (response indicator ) siga , power supply card (3-pps/m-230 ) , monitor module ( 2 input module ) (siga- , fiber optic interface module (3-fibmb 2 , fiber optic interface module (smxlo2 )

Central Government And Public Sector

CTN :45064376 Due date: 23 May, 202623 May, 2026 8.18 Lacs
Tender For supply of addressable type fire alarm system at in north paravur : : - sitc of addressable main fire alarm panel , sitc of repeater panel , sitc of addressable photo thermal detector , sitc of addressable manual call point , sitc of addressable horn cum strobe , sitc of fault isolator , sitc of addressable fire control module , sitc of response indicator , supply and laying of 2x1.5 sqmm fire alarm armoured cable , sitc of mcp signage , sitc of relay module

CTN :45024279 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of replacement of defective or senseless with compatible multi sensor smoke detector , xipe cross linked polythene thermostatic cable cable multi core , laying charges for cable including fire proof pipe , compatible addressable manual call point , compatible addressable sounder and strobe , online power backup source 1000va 60min 4 no 62 ah battery , addressable panel external surge supply with spd integration including 0.2 ohm rapid release surge cancellation device including wiring , installation and configuration , fire bell with manual call point including installation and electrical socket with wiring , annual maintenance contract for existing infrastructure of afds for 03 panel and allied equipment

Central Government/Public Sector

CTN :39671456 Due date: 29 Apr, 202629 Apr, 2026 NA
Tender For bid to ras corrigendum : supply of hvla hcdas and fdsiao - helicopter deck lighting , landing period designator , stabilised horizon reference system , advanced ship glide slope indicator , helicopter crash on deck alarm system , flight deck status indicating and ordering system , lso compartment lights with control gear , air briefing room light with control gear , lso console , ob spares , commissioning spares , special cables , documentation , training cost , servce engineer charges , cost of extended warranty , any other item

Central Government/Public Sector

CTN :44959016 Due date: 12 May, 202612 May, 2026 79.99 Lacs
Tender For supply of sitc of microprocessor based intelligent addressable main fire alarm control panel , sitc of repeater panel , sitc of intelligent analog addressable photo thermal detector , sitc of intelligent analog addressable photoelectric smoke detector , sitc of intelligent addressable duct detector including suitable photo detector , sitc of response indicator , sitc of fault isolator , sitc of intelligent addressable thermal detector , sitc of addressable fire control module , sitc of addressable fire relay module , sitc of addressable beam detector , sitc of manual horn cum strobe , sitc of addressable manual call point , sitc of 25 mm outer dia cpvc pipe , supplying and laying of 2x1.5 sqmm fire alarm armoured cable

Central Government/Public Sector

CTN :44676443 Due date: 23 Apr, 202623 Apr, 2026 NA
Tender For corrigendum : supply of fire detection alarm system spares d d - telescopic 4 section access pole , fire smoke and heat detector removal tool of adjustable diameter , fire detection aerosol dispenser suitable for testing detectors , non flammable, hfc free smoke aerosol smoke detector tester , glass elements for replacing broken glasses in manual call point
 Loading, Please wait...

Connect us via What's Up