Get complete information related to latest Addressable Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Addressable Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Addressable Detector Tenders.
Tender For tender for supply of fire alarm system =- philips pc-2300 spare fire alarm system panel mounted card addressabledetector interface module card adim card part nor-4015 101 80081 , philips pc-2300 spare fire alarm system panel mounted card non addressabledetector interface module card nadim card part nor-8215 3013 7230 , philips pc-2300 spare fire alarm system panel mounted card digital output card part nor- 4015 101 73762 , philips pc-2300 spare fire alarm system panel mounted card digital input card part nor- 4015 101 73041 , philips pc-2300 spare fire alarm system panel mounted card keyboard interface card part nor- 4015 101 73752 , philips pc-2300 spare fire alarm system panel mounted card modem cards dual cards part nor- pc-2304 , philips pc-2300 spare fire alarm system panel mounted card bus expansion cards part nor- 4015 101 57233 , philips pc-2300 spare fire alarm system panel mounted card power supply cards part nor- pc 2390 779 , philips pc-2300 spare fire alarm system panel mounted card lcd interface card part nor- 4015 101 73421
Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For supply of multi gas detector portable /handheld electro chemical type replaceable sensor and catalytictype as per annexure-a [ warranty period: 24 months after the date of delivery ] ]
Tender For supply of apollo make addressable type xp-95 optical detector as per attached specifications , apollo make addressable soteria multi-sensor detector as per attached spec , apollo make addressable xp-95 heat detector as per attached spec , apollo make addressable xp-95 manual call point as per attached spec , apollo make addressable xp-95 intrinsically safe optical detector as per attached spec , apollo make series 65 conventional optical smoke detector as per attached spec
Tender For supply of multi gas detector lel, o2, h2s & co combustible sensor detector (catalytic type) with inbuilt motorized pump, audio and visual alarm, 10 feet long sampling hose & probe, inbuilt rechargeable battery and charger, as per annexure a [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of multi gas detector lel, o2, h2s & co combustible sensor detector (catalytic type) with inbuilt motorized pump, audio and visual alarm, 10 feet long sampling hose & probe, inbuilt rechargeable battery 6h-8h with one additional spare battery. working time: 8h continuously (without alarms)and charger. specifications; accuracy: ?5% f.s. response time: 30s. lcd displays real-time and system status, alarms: led, audio and vibration alert for gas over or under range. low battery indication. sensor fault indication. explosion-proof grade : exiaiict3. protection grade : ip65. product package includes: hard carry case, gas detector, charger and usb cable, calibration cap, screw for cap, hanging cord. make: metravi, msa safety, honeywell or similar. [ warranty period: 30 monthsafter the date of delivery ] ]
Tender For bid to ras bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For supply of analogue addressable multi sensor detector with multiple sensitivity (adjustable at site) levelse.g. smoke, heat, rate of rise heat etc, programmable for timed automatic sensitivity selection with base, and other accessories as required.as per rdso specification no. rdso/spn/217/2021 ver 3.0 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For corrigendum : procurement of honeywell notifier make fdps spares for fstpp main plantbattery rooms - detector,fire,multi sensor,notifier, call point,mnl,nbg-12lx,notifier, communication module,ncm-f,notifier