Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarmsystem, fence alarmsystem covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser
Tender For corrigendum : providing connectivity of addressablefirealarmsystem installed in various buildings to main fire control room, nehru hospital, pgimer, chandigarh
Tender For operation and maintenance of 11kv sub station equipment, 500kva/320kva/125kva dg sets, internal electrical installations, water supply pump sets, addressablefirealarmsystem , ac plant, vrf system, fire fighting system, boom barriers and lifts at niti aayog, new delhi for the fy 2026-27. sh - repairing and annual preventive and periodical maintenance of 83hp wet riser system diesel engine of kirloskar makesubwork/packages:repairing and annual preventive and periodical maintenance of 83hp wet riser system diesel engine of kirloskar make
Tender For supply of set of spares for medha make vcd (vigilance control device) of wag7 conventional electric locomotives. set consists of 06 items as follows: 1) main unit vcd mvc682 v4 to medha part no.sp682000003; qty: 01 no. 2) cab unit assembly for vcd682 -v4 to medha part no.sp682000004; qty: 01 no. 3) led lamp-green to medha part no.sp682241006 ; qty: 02 nos. 4) led lamp-red to medha part no. sp682241007; qty: 04 nos. 5) led lamp-yellow to medha part no.sp682241008; qty : 02 nos. 6) vcd alarm buzzer to medha part no.sp682241010; qty: 02 nos. [ warranty period: 30 months after the date of delivery ]]
Tender For corrigendum : supply of vdc mv o p 4 20ma , digital energy meter connection 3 phase 3 wire ct ratio 10000 5 amp pt ratio 1575 kv 110 v50 hz acc class 2s make seccure apex 150 , transformer pt 415v 110v , portable digital megger test voltage , thermal o l relay mn2 4 2 to 7 5a , thermal o l relay 2 5 4 amp , dc clamp meter dc current 0 1a to 200a ac current 0 1a to 200a dc ac voltage 0 1v to 600v continuity data hold fa make motwane , control transformer t 1 input voltage 0 440v output s1 0 110 220 and s2 0 110 220 as per sample rating 50va , control transformer t 2 input voltage 0 440v output 0 18 24 as per sample rating 50va , heating element of esp hopper 0 5kw , transformer oil drum 210 lit , dehy breather for hvr transformer of esp , buchholz relay type gor 1 with alarm trip contact 1no plus 1nc , magnetic oil gauge with one tripping contact , prismatic oil level indicator size 150mmx60mm , glove valve size 25mm brass both side flange end , crc contact cleaner 300 ml cane , neoprene rubber sheet 1x2mtr thick 10mm , aluminium lugs 70sq mm als 226 e bolt hole 13mm make dowells , aluminium lugs 185 sq mm als 235 e bolt hole 17mm make dowells , aluminium lugs 120sq mm als 230 e bolt hole 13mm make dowells , aluminium ferrule 120sq mm make dowells , aluminium ferrule 150 sq mm make dowells , copper ferrule size 185 sq mm make dowells , copper ferrule size 120 sq mm make dowells , push button on off with element , hrc fuse3na 7805 orc 16 a make siemens , hrc fuse3na 7820 orc 32 a make siemens , mccbn 16r 150a 3p , ns type fuse 32 amp , ns type fuse6 amp , ns type fuse 25 amp , on delay timer 0 5 sec to 100 hours 24 240v ac dc , local remote switch 25a 440v brand kaycee siemens havell l t , voltmeter sel switchmodel srp1373way off , din type fuse rating 100 a , din type fuse rating 125 a , hrc fuse t a 32 rated for 32 amp code no sfb 8116032 , pin type insulator 0 4kv , petroleum jelly for battery , din type fuse hrc size 3 current rating 500 amp , rectifier fuses 150 amps semiconductor type , led indication lamp red yellow blue green 220v ac dc , dd module 236 amp 1000piv , dd module 260 amp 1600piv , dd module 70 amp 1000piv , mccb 150a 3 pole , motor cooling fan with cover for 2 2 kw gt cooling fan motor , control fuse ns type 2amp , control fuse ns type 4 amp , control fuse ns type 6 amp , din type hrc fuse 25a 415v ac size 00 , din type hrc fuse 32a 415v ac size 00 , din type hrc fuse 63a 415v ac size 00 , analogue ac voltmeter range 0 500v , analogue ac voltmeter range 0 500v ptr 415 110 v , analogue ac ammeter range 0 50 amp ctr 50 , dc voltmeter moving iron jewel bearing range accuracy , ammeter range 0 15amp ctr 15 1 , moving iron analog ac ampere meter ct ratio 400 5a d , d c ammeter moving coil range , ac ammeter range 0 25amp , aux contactor 2no plus2nc coil voltage 24v ac , aux contactor 3no plus1nc coil voltage 24v ac , switch disconnector fuse unit 2pole current carrying capacity 315 amp max operating voltage 600 v 50hz for one to one replacement , power contactor 3pole current carrying capacity 315amp max operating voltage 600v coil voltage 220 250vac 50hz dc for one to one replacement , local remote selector switch 10a model type 2s26b or equivalent for one to one replacement , ammeter rotary switch 12a r y b off 4 position 90 degree , voltmeter selector switch 12a ry yb br off , local remote selector switch 3 pole2 way without off 16 amp , tnc rotary switch 25amp spring return to neutral model type , switch //bid details 2 / 59 fuse unit 63a 3p , switch fuse unit 125a , thermal overload relay