Get complete information related to latest Administration Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Administration Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Administration Set Tenders.
Tender For bid to ras supply of cotton 500gm - bolus galactogogue strip of 4 , bolus prajna strip of 6 , bolus sulphadimidine strip of 4 , cotton absorbent pkt of 500 gm , disposable sterile iv infusion set , examination gloves pack of 100 , eye drop ciprofloxacin bott of 10 ml , fenbendazole 3 gm bolus strip of 2 , hepatobiliary syrup bott of 120 ml , inj analgin vial of 30 ml , inj avil vial of 33 ml , inj belamyl vial of 30 ml , inj meloxicam vial of 30 ml , inj rabies vial of 10 ml , lotion povidone iodine bott of 100 ml , needle 18 gauge , oint healmax tube of 30 gm , pdr hb strong sachet of 10 gm , pdr liv 52 pkt of 100 gm , pdr neblon pkt of 100 gm , pdr neosporin 10 gm , pdr timpol pkt of 100 gm , pendistrin intramammary tube , spray topicure bott of 100 ml , syp calcium bott of 1 ltr , tab praziquantel 50 mg, pyrantel 144 mg and fenbendazole 500 mg , inj dhppi plus l , tick collar large , lotion kiskin 100ml , syp sucralfate 200 ml , disposable surgical kit
Tender For corrigendum : supply of veterinary instruments and equipments - allis tissue forceps (20 cm.), artery forceps curved (15 cm ), artery forceps straight (15 cm ), forceps s.s. (20 cm), forceps s.s.(15 cm), haemostat straight s.s.(17.5 cm), haemostate curved s.s. (15 cm. ), mayo s scissors curved isi (s.s. 15cm), mayo s scissors straight isi (s.s. 15cm), scissors straight s.s.(12.5 cm), scissors straight s.s.( 17.5 cm), surgical gloves (standard), surgical mask (standard), suturing needle (assorted size) (traumatic/atraumatic cured/st.), suture thread silk/ nylon (10 mt. reel no.100, 0, 1, 2, 3), chromic cat gut (100, 0, 1, 2, 3 no.), needle holder s.s.(15cm), instrument trolly, dressing drum s.s. round 20 gauge (height 30cmx30cm dia.), b.p. blades (no. 22, 23, 24, 11, 12, 13,14, 16, b.p. handle s.s.(no. 3 ), b.p. handle s.s.(no. 4), kidney tray s.s.(15 cm length), tray small ss (250mmx300mm), hypodermic needle (15 x3/4"), hypodermic needle (18 x3/4"), vaccutainer with needle (with vacuum, 10 ml and needle of double bewell 16 no.), electrcally operated needle and syringe destroyer. destruction rate max. 1 minute per needle of 1.6 mm thickness with 80 mm length. min. 350 cutted hubs of syringes with needle burnt residue., bloodless castrator for small animals 9 (made of special high carbon steel coated for protection against rust formation), castrator imported, i/v fluid stand (s.s.), intra venous set (disposable 0 standard) ), scalp vein set (21 no. 0 22 no.), electric dehorner (30 cm length), trocar canula for sheep s.s.(15 cm), teat syphon (ss), drenching bottle (large) (metal 500 m), drenching bottle (small) (metal 200 ml), doctor coat tericot (free size), plastic apron, macentosh sheet (double colour), rubber arm sleeves with latex gloves (no. 9), gum boot, dog muzzle (assorted size), dog nail cutter (standard), measuring cylinders (50 ml graduated borosil glass ), measuring cylinders of (100 ml graduated borsil glass ), medicine carry bag (nylon 600 dpu coated padded, multipocket for medicine and surgical equipments ), jar with lid ss (2 kg. capacity), jug ss (2 ltr. cap.), thermos s.s. double insulated (1 ltr. cap., 30cm length, 7.5cm mouth dia with soulder carrying strap.), bucket ss (12 ltr capacity), california mastitis kit, centrifuge machine (bench top) for general purpose, canopy tent with carrying bag. frame made of steel powder coated pipe (23 gauge) 0 tetron cover (waterproof) with two folding chairs and one folding table, vaccine carrier (1.6 lit capacity with 4 ice packs), microscope binocular, autoclave electric, calf puller ss 316/304., animal catching device, cold boxes vaccine storage capacity 20 ltr. weight fully loaded 43.3 kg. empty weight 17.5 kg. external surface material plastic, internal lining material plastic , insulation material polyurathene, insulation thickness 110 mm,, refrigerator, thermocautery, veterinary urine analyzer with accessories, animal sling for large animals, cold cabinet/ cold room with 25% capacity of racks as deep freezer and 75 % as cold cabinet having 2-8 degree celcius temperature, digital display, alarm system for temp. beyond set point, hematology analyzer with accessories (three parts), semi automatic veterinary serum analyzer with accessories, verticle cold cabinets for vaccine storage, with storage temperature 2-8 degree celcius. temperature holding time atleast 12 hrs, at power failure. adjustable shelves., hot air oven, incubator, ice liner (ice lined refrigerator or freezer) compressor compartment0 hermetically sealed high quality compressor 230 v 50/60 hz. relatively noise less fan to cool down the compressor. all steel tubes protected with special compound against rust formation. 1 thermostate pre-stetted from the factory for 2 c - 8 . control panel situated at the front of the unit. light indicators for different functions, 1 digital thermometer to indicate the internal temperature, latest cooling system. insulation with thick polyurethane foam. foaming agent- cyclo
Tender For corrigendum : supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administrationset/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exha