Web Analytics Made Easy - StatCounter

Aerial Bunched Conductor Tenders

Get complete information related to latest Aerial Bunched Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aerial Bunched Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aerial Bunched Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Trust

CTN :45679919 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of miscellaneous electric items - steel tubular 9 mtr. long pole (st-410 sp33) , acsr weasel conductor 6/1/2.59 mm , 11 kv go, ab switch 3-phase, 3-pole, 200 amp vertical type with rod heavy duty , back clamp for 9 mtr. pole with fitting , 11 kv horn gap fuse set (hg set) 3-phase 400 amp polymer type heavy duty , la set station type (gapless surge arrestor, 9kv, 10 ka, la with polymer housing station type heavy duty) , xlpe pvc cable single core 300 mm sqr. (300 sq mm cable 1.1 kv grade, pvc insulated standard conductor frls type) , 11 kv polymeric pin insulator 12 kv, 5 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm , insulator disk 11 kv (11kv polymeric composite discs insulator with pin and gl fittings, 12 kv, mainfalling load 45 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm) , channel 100.00 mm x 50.00 mm x 5.00 mm (10 feet long) , nut bolt full thread with washer 4"/6" heavy duty , wedge connection / pg clamps , danger plate and clamps , g.i. bracket wire for anti climbing , 3 phase 4 wire trivector meter with ct/pt unit , aluminium thimble 185 mm , lv distribution box for 400 kva dtr with mccb for incomer & sfu's for outgoing circuits , stay set (gi rod with clamp) - galvanised stay set with 50x8mm stay clamp, gav. insulator (02 nos.) anchor plate (200x200x6mm) nut-bolt 2 nos. turn-buckles, 1.8 m long 16 mm diameter solid g5 stay rod & 7/3. 15 mm dia gi standard wire complete , g.i. guy rod complete with clamp and insulator , anti climbing device with clamp , guy / stay wire 7/14, galvanized steel, typically hot-dip zinc-coated for corrosion resistance , giv cross-arm with top bracket and gi channel-arm including clamp (gi v cross arm with top bracket including clamp and gl channel x-arm including clamps and braces) , channel 75 x 75 x 6mm (10 feet long) , g.i. earthing wire 8/10 mm

State Government

CTN :45413292 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For job work of supply, erection & connection of xlpe insulated aerial bunched conductor (abc) 415 v lt line with rsj pole from stage -iv evt entrance gate to surge well transformer area and laying of lt cable from diesel generator set area stage -iv to inter audit entrance gate at stage -iv, pophali.

CTN :45352757 Due date: 08 Jun, 202608 Jun, 2026 11.41 Lacs
Tender For street light accessories and phase wire work in losal area - work, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a"attached with this bsr ., 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, suspension clamp with eye hook & pole clamp, dead end clamp with eye hook & pole clamp, p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , din rail etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr, 2.0 mm thick, providing & fixing of ac operated heavy duty 230 /440 volt power contactor as per pwd specification for electrical works, isi marked is/iec 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., 4 pole power contactors with following ac 1 rating 63 amp, providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming conforming to iec 60730-1 and 60730-2-7 etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., one day & week reserve (analog type ), sitc of 3 /4 pole current limiting moulded case circuit breaker (mccb) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 v, 50 hz; o/l & s/c settings , conforming to is/iec 60947 p -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 690 v. provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in-charge. for additional technical parameters of product/ work refer annexure a attached with this bsr, 4 pole mccb with thermal magnetic release up to 100 amp , 10 ka, fixed o/l & fixed s/c setting, pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia. b class g.i. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly-propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350mm. and height 250 to 300 mm. and embodying the pipe compl

CTN :45255398 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply of heat resistance, 2 core compensating cable, for use with s type disposable thermocouple (pt .- pt./rh. 10%) as inside cable in lancer pipe each core shall be individually insulated with teflon, overallinsulated with teflon & above all will be insulated fiber glass. positive: copper & negative :cupronic, conductor size 23/36 swg, over all od 5.0mm make - surya, flame india, pro-heat, v-smart , bhatter cables, jpcor similar in all respect. each roll 100 mtrs. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45204092 Due date: 30 May, 202630 May, 2026 NA
Tender For job work of supply, erection & connection of xlpe insulated aerial bunched conductor (abc) 415 v lt line with rsj pole from stage -iv evt entrance gate to surge well transformer area and laying of lt cable from diesel generator set area stage -iv to inter audit entrance gate at stage -iv, pophali.

Central Government/Public Sector

CTN :44901754 Due date: 18 May, 202618 May, 2026 NA
Tender For corrigendum : supply of kapton covered copper conductor dimension of bare copper 6.90 plus/minus 0.07mm x 3.30 plus/minus 0.05mm and corner radius 0.8 plus/minus 0.1 mm, dimension over 2/3rd positive lap 67 percent to 70 percent insulation 7.26 x 3.63 mm max. as per spec. no. 4tms .095.002 rev 0 dated 23-06-2011 for power coil of hitachi armature. [ warranty period: 30 months after the date of delivery ]

CTN :44808034 Due date: 20 Apr, 202620 Apr, 2026 15.00 Lacs
Tender For work of providing electrical repairing material for led lights installed in the municipal area. - providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un-arrmoured aluminium cable confirming to is:1554 p-i/is:7098 p-1 of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6%, inner / outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench / cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure 'a' attached with this bsr 1 6x 2 sq. mm. (insulated) , providing & fixing of 240/415 v ac mcb with positive isolation ka breaking capacity (b/c/d tripping characteristic as load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996)/conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl/cpri / erda accrediated lab type test reports & all as per pre approved by engineer in 0.5 a to 5 a ratin , double pole mcb(with b/c curve tripping characteristics) , four pole mcb (with b/c curve tripping characteristics) , supplying and fixing of aluminium (iec 60105 iso 209-1,2) / copper (iec 60028) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr. , main panel street light control panel commissioning kiosk type weathe proof panel out door main cubic panel size 750x1250x500 they shall be in two section comaring as follows bsr 2017 (59.57) , supply & drawing wiring for sub mains isi marked (is:694) 110volts grade pvc insulated flat twin core sheathed solid aluminium 4 sq mm 2 core flat
 Loading, Please wait...

Connect us via What's Up