Get complete information related to latest Aerosol Generator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aerosol Generator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aerosol Generator Tenders.
Tender For supply and installation of one number of aerosolgenerator 500 gms ( fire detection and suppression catridge) in lavatory for lhb coaches. note: safety clause must be followed according to annexure-a of dy.cple-ii l.no.rcf/emp/1 dated. 01.04.2025,as per drawing: annexure-g of rdso/pe/spec/ac/0184-2015(rev-1) or annexure-g.1 of rdso/pe/spec/ac/0192(rev-1) also permitted, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For grain moisture meter handheld humidity tester for wheat, rice, corn etc , food detector nitrate tester for fish, fruit, vegetable, meat, tds water tester for home health
Tender For supply of aerosolgenerator 500 gm ( fire detection and suppression catridge) for train set coaches to drawing number ts/mc-6-4-013, alt-a item- 1. and as per the technical requirement specified in annexure-g of rdso. spec. rdso/pe/spec/ac/0184-2015 (rev-1). note: annexure g1 of rdso specification rdso/pe/spec/0192 (rev-1) [ warranty period: 30 months after the date of delivery ] ]
Tender For providing, supplying and installation with testing demo of additional laboratory equipment for aggregate, cement and mix-design at quality control sub division, rander, dist. surat.- providing and supplying & installation with testing demo of vicat needle apparatus for testing of initial, final seeting time & consistency of cement test. one complete set. confirm to 18:5513 , providing and supplying & installation with testing demo off vicat mould, , providing and supplying & installation with testing demo of vicat glass plate, , providing and supplying & installation with testing demo of le-chatler mould including two glass plates and lead weight as per is set of six., , providing and supplying & installation with testing demo of le-chater flack, , installation with testing demo of slump test apparatus with tamping rod 16 mm dia x 600 mm long graduated., , providing and supplying & installation with testing demo of humidity chamber refrigerated-inner 8.8-45x45x45 cm-92 liter for temperature and humidity control with over temperature protection audio alarm system, , providing and supplying & installation with testing demo of servo voltage stabilizer -3kva-single phase for humidity chamber., , providing and supplying & installation with testing demo of humidifire with controler digital-confirming ito indian standard codes, , providing and supplying & installation with testing demo of whatman fliter paper-40 for blain air permeability test apparatus for fineness of cement, confirming to indian standard codes., , providing and supplying & installation with testing demo of precision electronic balance-600 gmm 01 gm (10mg)-confimming to indian standard codes., , providing and supplying & installation with testing demo of cement morter cube mould-7.06 cm-for cement confirming to indian standard codes (18 10080, 84031), , providing and supplying & installation with testing demo of 90 micron is sleve, , providing and supplying & installation with testing demo of gauging travel 8 anch. (200 mm)-confirming indian standard codes., , providing and supplying & installation with testing demo of temperature meter concrete, , providing and supplying & installation with testing demo of room temperature meter or thermo hygrometer, , providing and supplying & installation with testing demo of tds meter pen type, , providing and supplying & installation with testing demo of ph meter - pen type, , providing and supplying & installation with testing demo of measuring cylinder -borosilicate glass-100ml, , providing and supplying & installation with testing demo of measuring cylinder -borosilicate glass-250ml, , providing and supplying & installation with testing demo of measuring cylinder -borosilicate glass-500ml, , providing and supplying & installation with testing demo of measuring cylinder -borosilicate glass-1000ml, , providing and supplying & installation with testing demo of standard weight box-8.8.-1 mg-200 gm-class f1 (with nabl calibration), , providing and supplying & installation with testing demo of buoyancy balance with electronic balance 10 kg x 0.1 gm, , providing and supplying & installation with testing demo of 1.) distance piece-50mm height-nos 2.) distance piece-30mm, , height-inos, , machine, , providing and supplying & installation with testing, , demo of electronic platform, , balance-100 kg-, , 10 gm platform size 600 x, , , , providing and supplying & installation with testing demo of g.j. tray 1000x 1000 x 50 mm confirming to indian standard codes., , providing and supplying & installation with testing demo of bnd- ordinary portland cement standard specific area (blaine) one set surface, , providing and supplying & installation with testing demo of wash bottle 1000ml, , providing and supplying & installation with demo of spatula testing, , providing and supplying & installation with testing demo of fil
Tender For procurement of spares of m/s yil make hydrogen gas density analyzer system for ph ii at sgtps, mppgcl, birsinghpur - hydrogen gas density sensor model: gd40t detector unit along with compatible pressure transmitter for pressure compensation supply: 100 to 240 v ac, 24 v dc output: 4 to 20 ma dc sample gas: hydrogen gas flow: 0.1 to 1 l/min ambient temperature: -10 to 60 oc humidity: 5 to 95% rh process connection: 1¼ npt (f) electrical connection: 1½ npt (f) enclosure: nema type 4x fm explosion proof and intrinsically safe area classification: zone-1, zone-2 gas group: group-i, iia, iib bin code: 832-49-492-689-01, hydrogen gas density convertor unit model:- gd402t-a-e-e, pressure transmitter model:- ejaf3 oil filter, rota meter (flow meter) work portion, expert servicing, calibration of m/s yil make h2 purity analyzer installed in unit no 4 ph-ii, sgtps, mppgcl, birsinghpur (4 days)
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For supply of aerosolgenerator - 500 gms. (fire detection and suppression catridge) for vande bharat train set coaches to drg. no. ts/mc-6-4-013 alt. b, item no. 1 & as per the technical requirement specified in annexure - g of rdso. spec. rdso/pe/spec/ac/0184-2015 (rev-1). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of digital multi meter , digital barometer , clamp meter , electronics screw driver set , electric blower , temperature and humidity meter , dc regulated power supply , digital oscilloscope
Tender For rate contract of supplement medicine and diagnostic - description of supplement medicine & diagnostics, albendazole tablet 400 mg, calcium tablet (500 mg elemental + vit d3 250 iu), ifa red: prophylactic (preventative) dose: typically one tablet daily (containing 60-100 mg elemental iron and 400-500 g folic acid), usually starting after the first 12 weeks of pregnancy and continuing for a minimum of 180 days.therapeutic dose: if you are diagnosed with anemia, your doctor may increase the dosage to two tablets daily.postpartum: it is often recommended to continue taking these supplements for at least three months after childbirth., digital hemoglobinometer: measurement range: typically 0 - 25.6 g/dl (or 0 - 256 g/l).methodology: reflectance photometry or absorbance spectrophotometry.sample type: capillary, venous, or arterial whole blood.sample volume: very small, usually between 8 l and 15 l.time to results: under 15 - 60 seconds.memory capacity: stores 500 to 1,000 test results with date, time, and patient id.power: rechargeable battery or aa batteries., digital hemoglobinometer strips: sample type: fresh capillary whole blood (finger prick) or venous whole blood.blood volume: 10 l to 30 l (approximately one drop).measuring range: usually 3.0 to 25.6 g/dl.result time: between 15 to 60 seconds, depending on the testing mechanism.operating temperature: stable between 2 c to 40 c.shelf life: typically 18 to 24 months from the date of manufacture when stored properly. digital hemoglobinometer will be free as per company policy., glucometer: measurement range: typically 10 mg/dl to 600 mg/dl (or 0.6 mmol/l to 33.3 mmol/l). results falling above or below this range are generally flagged as "high" or "low".testing method: usually employs electrochemical biosensors (like glucose oxidase or glucose dehydrogenase) to generate a detectable electrical current from the blood sample.accuracy standards: devices generally conform to en iso 15197:2015 performance criteria, which require 95% of results to fall within 15 mg/dl of lab values at concentrations 100 mg/dl, and within 15% at concentrations 100 mg/dl.hematocrit range: most meters accommodate blood hematocrit levels between 10% and 65%.power source: usually powered by 1 to 2 standard coin-cell batteries (e.g., cr2032).physical specs: lightweight and compact, typically weighing between 40g and 75g., glucometer strips: blood sample volume\(0.3\text{ \mu l}\) to \(1.0\text{ \mu l}\) (capillary blood)measurement time5 secondsmeasurement range10 mg/dl to 600 mg/dl (varies slightly by meter)enzyme technologyglucose oxidase (god) or glucose dehydrogenase (gdh)shelf life12 to 24 months (usually 3 to 6 months after opening)operating conditions4 c to 30 c (storage), 10-90% relative humidity. glucometer will be free as per company policy., ors: recommended by the world health organization (who) and unicef- sodium chloride (nacl): 2.6 gglucose (anhydrous): 13.5 gpotassium chloride (kcl): 1.5 gtrisodium citrate dihydrate: 2.9 gtotal weight: 20.5 g