Tender For purchase of biochemisty lab equipments - incubator (pac), key features- temperature control: precise temperature control to maintain a consistent temperature environment.- humidity control: adjustable humidity control to simulate various environmental conditions.- co2 control: optional co2 control to maintain a specific co2 level for cell culture applications.- shelving and storage: adjustable shelving and storage options for flexible sample storage. performance specifications- temperature range: 20-50 c.- temperature uniformity: 0.1- 0.5 c.- humidity range: 20- 90 % rh.- co2 range: 0-20 %.safety features- overheat protection: automatic overheat protection to prevent damage to samples and equipment- temperature alarm: audible and visual temperature alarms to alert users of temperature deviations- door lock: optional door lock to prevent accidental opening and maintain temperature stabilityadditional features- data logging: optional data logging capabilities to track temperature, humidity, and co2 levels- remote monitoring: optional remote monitoring capabilities for real-time monitoring and alerts- validation and testing: optional validation and testing capabilities to ensure equipment performance
Tender For purchase of equipments - purchase of equipment: temperature compatible electrochemical device, the bidder is required to supply a handheld and wireless dual-channel potentiostat / impedance analyzer along with all necessary accessories and a compatible climate-controlled environment setup. the system must support sequential electrochemical measurements using both screen-printed electrodes (spes) and conventional electrodes. system specifications dc potential range: 2 v, maximum current range: 3 ma eis frequency range: up to ~200 khz, should support following techniques- linear sweep voltammetry (lsv), cyclic voltammetry (cv), square wave voltammetry (swv), differential pulse voltammetry (dpv), normal pulse voltammetry (npv), chronoamperometry (ca), pulsed amperometric detection (pad) open circuit potentiometry (ocp), multistep amperometry (ma) electrochemical impedance spectroscopy (eis) with scanning frequency mode and fixed frequency mode internal memory: onboard storage with capability to transfer data to pc via software interface usb or battery-powered operation wireless connectivity with tablet or pc (e.g., via bluetooth or wi-fi) environmental control requirementto maintain a consistent, controlled testing environment, a minimum 1.5 ton air conditioner (ac) unit must be supplied and installed along with the system. software & data handling software must allow real-time monitoring and data transfer from internal memory to pc user-friendly interface with exportable data in standard formatsdeliverables handheld dual-channel potentiostat / impedance analyzer, spe connector & cell cable, required software 1.5 ton air conditioner installation and commissioning user manual and documentation warranty & support minimum 1-year warranty on the entire system technical support and software updates during the warranty period
Tender For e tender for supply and installation of physiotherapy equipment 2025 second call -"foot balance scanner• the unit should have interface integrated 24” color touch screen, • the unit should have interactive foot balance 3d scanning with analysis- and with software,• the unit should have scanning speed 5-15 s per phase with optimal connectivity, • the unit should have scanning accuracy +/-1 mm for the foot size, benchmarked on plastic foot models, no need to remove socks to scan, • the scanner is designer for normal environmental conditions; (a) indoor use, (b) altitude up to 2000m, (c) temperature 5°c to 40°c, (d) maximum relative humidity 80% for temperatures up to 31°c decreasing linearly to 50° relative humidity at 40°c, (e) mains supply voltage fluctuations up to +/- 10% of the nominal voltag, (f) temporary overvoltages occurring on the mans supply, (g) applicable pollution degree 2, • the unit should be supplied with power plug 10m cable (white) + adapter , • the unit should be internet connection wired preferred (rj45) preferred 100+ mbps, min 10 mbps, • the unit should have wi-fi intel wi-fi 6 ax201, • the bidder provides size recommendations in millimeters and us-, eu-, and uk sizes • the device is class 1 laser compliant, • the unit dimensions (cm) 72 × 96 × 144, • the unit weight (kg) 70 total, • the unit 60.5 (metal frame w/o electronics), • the unit supply 3 sets of reinforcement, • the unit supply 100 pairs insoles for sports, medical, diabetic and formal insoles from size 28 to 52 all even number free with the machine, • the unit certified ce european / fda approved"
Tender For corrigendum : design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-progra