Tender For electrical installation work incl. supply, installation, testing and commissioning of airconditioningmachine at proposed converted x-ray room and cr room, previously named as sample collection or store room and injection room respectively at katwa sd hospital, purba bardhaman.
Tender For supply, installation, testing and commissioning of 1.5/1.8 tr single phase split type airconditioningmachine for science and technology deptt. at 4th floor in east block in bikash bhawan.
Tender For supply, installation commissioning of airconditioningmachine along with allied electrical work at raybagini rani vobhosankari auditorium under un pur block, howrah (2nd call of nit 10 of 2025-26 sl. no. 04)
Tender For repairing and servicing work of hitachi make split ductable type airconditioningmachine installed at different areas of howrah court building.
Tender For annual comprehensive maintenance work for split type air-conditioningmachines at br-ii office building and other institutions under br-ii kmc.
Tender For annual maintenance contract for airconditioningmachine situated on 3rd floor and 4th floor of dc stf office at 112, ripon street, kolkata-700016, during the year 2025-2026.
Tender For corrigendum : supply of spares and annual maintenance contract of sugar bagging machine on door delivery basis including servicing at sugauli plant, east champaran - supply of spares & servicing of sugar bagging machine at hbl plant, sugauli as per below mentioned & attached tender document:, weighing controller - htf 009, bag clamp input switch idca 122q, load cell 110 kg capacity make: sensotronics, load cell junction/ summing card, load bucket sensor m18 npn no, smps omron sbfs c05224 j, modular relay 8 channel- c/024v dc, air cylinder for course/fine/super fine- 40x50 compact- janatics, air cylinder for load bucket- 40x16 basic- janatics, air cylinder for bag clamp- 50x50 compact- janatics, modular relay 8 channels- c/024v dc, solenoid valve janatics 1/4-5/2.220v ac, make: janatics, mouth rubber- make: hi-tech, bag clamp rubber pad (1 set of 3 nos) make: hi-tech, rubber packing load bucket (1 set of 3 nos) make: hi-tech, frl unit 3/8 make: janatics, servicing of sugar bagging machine at hbl plant, sugauli as per below mentioned & attached tender document:, job scope includes providing annual maintenance contract (amc) and associated service engineer support shall include, but not be limited to, the following activities to ensure reliable performance of the sugar bagging machine throughout the crushing season:i. cylinder servicingii. complete machine servicingiii. controller and eprom memory maintenanceiv. seasonal re-commissioningplease refer to the detailed work scope mentioned under special terms & conditions.kindly note that all work shall be carried out by trained service engineers with adequate experience in handling similar machinery. the contractor shall ensure availability of necessary tools, consumables, and replacement parts (mentioned above) during servicing.
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage
Tender For corrigendum : supply, installation, testing and commissioning of airconditioningmachine and allied electrical works in different rest rooms of baruipur ssh, south 24 pgs rattirer sathi, 2nd call.