Tender For auction sale of damaged motor various size and damaged excitor (bpm-1),heat exchanger,metal scrap, gi sheet,gi ridge, fire extinguisher cylinder(bpm-2),old and damaged ct 110kv, sf6 circuitbreaker pole110kv (bpm-3),110kv sf6 cb with mechanism box without structure (kls-2),vpi( vaccum pressure impregnation) insulated generator coils (mzr-1),lt abc scrap, ht abc scrap, lt xlpe cable scrap (ktr-1)
Tender For testing and calibration of different electrical equipment related to ht installation (vcb, transformers, starters, motors, protective relay etc.) at chhal ocm , secl, raigarh area . - item description, testing & calibration of protective relay ( idmt/overhead relay, elr, cdg, earth fault relay, no volt relay/master trip relay, under/over voltage relay), testing of 6 nos. 6.6 kv/230v, 25 kva, transformer, 1 no. 1250kva, 33kv/3.3kv transformer and 1 no. 315kva, 3.3kv/440v transformer, this includes magnetizing test, magnetic current test, vector group test, ir/pi test, ratio test, acidity test, as per latest cear field testnote: work also includes prepartion of test report etc., testing of 6.6 kv ht motor, this is include ir/pi test, inductance test asper latest cear flied test, test and calibration of 6.6 kv vacuum circuitbreaker panel having 5 nos. panels received from j&k area at chhal ocm sub station and 2 no. field vacuum circuitbreaker chhal ocm sub station, 1 no. sf6 circuitbreaker dharam sub station, which includes ir test, contact resistance test, close open test, as per latest cear field test, ir/high voltage test of cables, testing & calibration of all other protective/measuring equipments (meggers, lux meter, high voltage detector, multimeter etc.) in mine & surfacenote: work also includes prepartion of sigle line daigram, mine plan, test report etc., test of 6.6 kv overhead lines, which includes ir test of conductor, and post , disc insulator ir test as per latest electricity rule, test of 6.6 kv ht starter panel, which includes ir test, contact resistance test, close open test, as per latest cear field test, total impact of gst for the purpose of ctc
Tender For supply of anti pumping relay 11 pin 110v ac, part no. 1901709 , rectifier bridge unit 60 or 63a 600piv 100v, part no. 1925362 , machanism motor wound spring charged 25k, part no. 1435279 , switch auxiliary assembly, part no. 2120276 , spring charging motor, part no. 1435530 , mechanism catch 25ka, part no. 1435292 , shunt trip coil 110 v dc, part no. 2064674 , vtc or closing coil 110 v dc, part no. 2064613 , fuse, ht,pt,11kv,5a , pt resin cast 3ph 5 limb 6.6kv or 110v or 63, part no. 2267718 , epoxy resin cast current transformer rat, part no. ba1132 , current transformer ctr 600 300 or 5, part no. ctr600300 , relay e or l 50a 1a 110v ac, part no. 1902284 , idmt relay, part no. p0083 , bus bar spout 1200 amp, part no. mv3308 , support insulator for fixed type vcb p00, part no. p0063 , 3.3kv or 6.6kv off load isolator assy upt, part no. 100030 , clamp, al,55mm,strght,busbr , switch, lmt,stopper,220v,10a,2no plus 2nc , padlocing, part no. pcvc3338 , switch control breaker pistol grip, part no. 2121074 , mvng contact, isltr,11kv,outdoor,630 or 800a , vcb 11 kv 1250a25kambl, part no. 418535
Tender For single e -tender enquiry for conclusion of rate contract (rc) with oem for two years for supply of spares of flp electrical equipments of mine line pvt ltd make-spares of flame proof aircircuitbreaker-, spares of 5kva lighting transformer, , spares of transwitch unit 315kva ht side 3.3 kv/550-570v, , spares of tran switch unit 315kva lt side 3.3kv/570-550v, , spares of transwitch unit 315kva ht side 6.6kv/550, , spares of transwitch unit 315kva lt side 6.6kv/550v, , spares of gate end box 550v, , spares of lt starter type cp1, , spares of lt starter type cp2, spare for vacuum circuitbreaker 3.3 kv, spare for vacuum circuitbreaker 6.6 kv, , spares for ht flp/ 3.3kv starter, , spares for ht flp/ 6.6 kv starter, spares of lighting cum signalling unit, , spares for flp plugs & sockets 200a restrained type, , spares for 6.6kv flp coupler & adopters type:, , spares for drill panel, , spares of bell & bell transformer, , spares for 3.3kv flp coupler & adopters type: r31, r32 & r3
Tender For corrigendum : procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuitbreaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuitbreaker for 100a with complete assy. , circuitbreaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuitbreaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuitbreaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance
Tender For bid to ras supply of split air conditioner including green ac, wall mount type (v2) (q2) , supply of 11 kv, 800 amps ht vacuum circuitbreaker bus coupler, indoor panel conforming to iec 62271, 200, 25 ka for 3 sec, all as mentioned in specification and as directed , installation, testing and commissioning of 11 kv, 800 amps, ht vacuum circuitbreaker, bus coupler indoor panel , supply of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp or nearest higher rating bus bar totally sheet metal enclosed matching with ht panel including busbar , installation, testing and commissioning of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp , shifting of existing 8 nos vcb for installing of bus coupler between existing vcb and connect the bus coupler complete
Tender For auction sale of condemned plant and machinery: advani orlikon portable mobile motor,condemned plant and machinery:hydraulic pipe bending machine,condemned plant and machinery: rashi mini annual rate contract welding machine,condemned plant and machinery: oleum storage tank,condemned plant and machinery: ht ocb panel,condemned plant and machinery :transformer 1110.433 kv,condemned plant and machinery : vacuum circuitbreaker-36 kv,condemned plant and machinery : oleum storage tank(t101 b),condemned plant and machinery: csa storage tank,condemned plant and machinery : chemical proportionate dozer,condemned plant and machinery : instrumentation comprising of steam pressure