Get complete information related to latest Air Circulator Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Circulator Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Circulator Fan Tenders.
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)
Tender For supply of commercial cooler, heavy duty fiber body, water tank capacity 90 litre, power consumption 340 watt, high air delivery 7500 cub meter per hour, 100 percentage copper winding motor, air throw 80 feet, 4 castor wheels for easy mobility, abs fan blades, large honeycomb cooling pads, inverter compatibility, metal blades, 3 speed levels(high/medium/low), make orient/singer/khaitan or equivalent approved make [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, testing, installation and commissioning air cooling machine of capacity 51.000 cmh with 2 nos. centrifugal fan, 02 no 7.5 kw electric motor, v belt drive for both the fans, celdek pads, 4 bendpvc eliminators, water pump 1 hp (1w-1s) water distribution system with pumps, piping's, valves etc, air intake filters, g.i air intake louvers, fan outlet dampers and complete in all respect as per spec. attached with annexure "a" [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of general electric items b b - wire 22swg , glass sleev 14 mm , slip ring for cane unloader bbl make 10 kw motor , exhaust fan 24 , plastic cooling fan for 5 00 hp motor , plastic cooling fan for 7 5 hp motor , plastic cooling fan for 10 hp motor , havells make auto cut hot air blower 2000 watt with overheat protection , soldering iron 65 watt , soldring wire , plastic cooling fan for 50 hp motor , teflon rod dia 65mm length 300mm , glass sleev 16 mm , mash rum type push button red , mash rum type push button blue , plastic cooling fan for 15 hp motor , carbon brush 12 20 32 , mettalic carbon brush 20 15 8 , carbon brush 30 20 100 , timer st 800 , carbon brush 21 31 37 , porcelean kit kat200 amp 415 v standard make , fuse wire 6 amp , fuse wire 10 amp , fuse wire 16 amp , dol starter empty box mk1 , dol starter empty box ml2 , exhaust fan 16 1 phase 960rpm ci body crompton havells make , carbon brush 20 32 40 , rocker arm 12 5 hp kec slip ring motor , h t connector 3 way , h t connector 6 way , potentio meter 500 ohm 2 w 10 turn bourns make , diode 6 amp , step down double phase transformer 415 vac to 24vdc , usha bajaj make room heater with ss reflector and body , dc solenoid coil for hydraulic grab for reverse forward direction , ss seamless ring size 1 for cane unloader , karam make industrial safety belt , silk rope 3 4 resham , foldable aluminium ladder 16 ft , amp meter 400 5 96 96 , amp meter 0 100 5 96 96 , amp meter 150 5 96 96 , limit switch 1 no 1 nc type ls 011 10 amp 500 v , frequency meter 96 96 , frequency meter digital type , air cooled resistance box for 12 5 hp 15 hp bbl make slipring motor , analog rpm meter make beacon sensor type input magnetic picup no of teeth 06 range 0 8000 rpm , selector switch for volt meter , selector switch for amp meter , volt meter 96 96 0 500 vac ae make , current transformer ct 250 5a , amp meter 300 5 96 96 , amp meter 600 5 96 96 , dyno pack with controller , current transformer ct 300 5a , current transformer ct 400 5a , current transformer ct 600 5a , current transformer ct 500 5a , current transformer ct 100 5a , carbon holder for 12 5 hp slip ring motor cane unloader motor , current transformer ct 500 1 a , amp meter 500 5 96 96 , amp meter 800 5 96 96 , porcelean kit kat 100 amp 415v , amp meter 250 5 96 96 , amp meter 1200 5 96 96 , timer 800 q 1 no 1 nc , portable single phase welding machine 220 vac , current transformer 1200 1 , current transformer 1200 5 , ictpn switch 200 amp , metravi make nctm 200 contact on contact combined digital tacho metermeter , diamond hammer drill bit size 6 mm for aluminium busbar drilling , diamond hammer drill bit size 8 mm for aluminium busbar drilling , diamond hammer drill bit size 10 mm for aluminium busbar drilling , diamond hammer drill bit size-14 mm for aluminium busbar drilling
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty aircirculators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49