Get complete information related to latest Air Cleaner Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Cleaner Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Cleaner Filter Tenders.
Tender For supply of element as/aircleanerfilter (outer) oem: ca part no.: 2925863 sub. 5725184 make:caterpillar [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only aircleanerfilter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only aircleanerfilter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only aircleanerfilter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For bid to ras supply of element aircleaner , filter fuel , mirror assy out rear view rh , relay assy , switch assy combination , tank water reserve , radiator assy
Tender For tender for supply of mist eliminator : -mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -3 air washer , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -3 air washer. , suction filter frame as per attached specification and drawing for control building -3 air washer , pump drain line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump suction line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump discharge line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump base frame as per attached specification sheet for control building -3 and control building -4 air washer. , suction gate valve of size 100 nb as per attached specification and drawing for control building -3 and control building -4 air washer , discharge globe valve size 80 nb as per attached specification and drawing for control building -3 and control building -4 air washer. , suction strainer 100 nb as per attached specification and drawing for control building -3 and control building -4 air washer , discharge non return valve -nrv- 80 nb as per attached specification and drawing for control building -3 and control building -4 air washer. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -3 airwasher. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -3 air washer , mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -4 airwasher. , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -4 air washer. , suction filter frame as per attached specification and drawing for control building -4 air washer , pump drain line with flanges and fittings as per attached specification sheet for control building -4 air washer. , pump suction line with flanges and fittings as per attached specification sheet for control building -4 air washer , pump discharge line with flanges and fittings as per attached specification sheet for control building -4 air washer. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -4 air washer. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -4 air washer