Get complete information related to latest Air Conditioner Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Conditioner Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Conditioner Unit Tenders.
Tender For corrigendum : supply, installation, testing & commissioning of 1 ton capacity, 5- star rating, inverter split airconditionerunit as per attached annexure-b [ warranty period: 30 months after the date of delivery ]]
Tender For corrigendum : providing comprehensive annual maintenance estimates to tower and split airconditionerunits at court halls (third floor) and digitalisation wing (4th floor) at c-block in the extended premises of high court for 11 months i.e., from 01.05.2026 to 31.03.2027.
Tender For corrigendum : carrying out certain electrical works, networking , epabx system , providing of airconditioners units, motor pump sets and 7.5kva ups in the quarter no 8 at road no 12 banjarahills, hyderabad. part c:providing epabx system (5th call)
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For supply of air conditioning material on f.o.r / door delivery and callup basis at hbl plant sugauli, east champaran and lauriya, west champaran, bihar
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)
Tender For corrigendum : supply, installation, testing, commissioning and trail run of machinery and equipment on turnkey basis for godavari coconut association - schedule a, effluent treatment plant, rainwater harvesting setup, water processing setup including ro water tank plant 8000 lph along with sump 50000 kl, schedule b, rooftop solar setup 650 kva, schedule c, electrical installation & equipment s including 700 kva transformer, schedule d, coconut primary processing:storage containers attached with electric chain hoist system and coconut dehusking & deshelling setup, schedule e, pairing system setup with conveyor, coconut oil extraction setup with provision for testa & virgin oil, schedule f, coconut meat processing and milk extraction setup, schedule g, quality control (qc & qa lab) setup, industrial air conditioning, dg set 320 kva, schedule h, training skill development setup, schedule i, material handling equipment s
Tender For supply, installation, testing and commissioning of airconditionerunits for x ray room at hospital and ac (vigilance) office under ftr hq bsf jammu
Tender For supply delivery installation and commissioning of 10 nos of 1.5 tonne capacity 5 star split airconditionerunits with accessories to be installed at hostel building in training centre - supply, delivery, installation and commissioning of following materials., supply and fixing of 1.5 tr 5 star split type ac unit, supply and fixing of double booster voltage stabilizer - 4kva, supply and fixing of ms stand for fixing out door unit, supply fabrication and fixing of ms channel for mounting the air conditiong outdoor unit, supply and laying of 5/8" and 3/8" copper pipe (extra beyond 3 meters supplied with ac unit), sub total (excluding gst), gst @18%