Tender For supply of butterfly valves (v2) as per is 13095 (q2) , pidbv with 3 way modulating valve and thermostat 65 mm dia , pidbv with 3 way modulating valve and thermostat 50 mm dia , pidbv with 3 way modulating valve and thermostat 40 mm dia , pidbv with 3 way modulating valve and thermostat 25 mm dia , pidbv with 3 way modulating valve and thermostat 20 mm dia , ms pipe 125 mm , ms pipe 100 mm , ms pipe 80 mm , ms pipe 65 mm , ms pipe 50 mm , ms pipe 40 mm , ms pipe 25 mm , ms pipe 20 mm , 125 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 100 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 80 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 65 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 50 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 40 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 25 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 20 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , butterfly valve 25 mm , butterfly valve 20 mm , pressure gauge 0 to 100 psi , thermometer 0 to 50 degree , auto airvent with 15 mm dia , gi volume control damper , motorised on or off type actuator , 20 mm y strainer with ss perforated screen , 25 mm y strainer with ss perforated screen , 40 mm y strainer with ss perforated screen , 50 mm y strainer with ss perforated screen , 65 mm y strainer with ss perforated screen , 24g gi sheet metal duct 0 decimal 63 mm , 22g gi sheet metal duct 0 decimal 8 mm , 50 mm acoustic insulation for ahu room , volume control supply air diffuser , without volume control retur air diffuser , return air grill , fresh air grill with volume control , pre-filter 10 micron 600 x 600 x 50 mm , hdgi cable tray 300 x 50 x 1 decimal 6 mm , hdgi cable tray 150 x 50 x 1 decimal 6 mm , compressor oil rl 170 h , refrigerent gas r 22 or 134a , solenoid valve 220 v 50 hz , drier core filter for 12 decimal 5 to 30 tr ac plant , txv for 12 decimal 5 tr compressor
Tender For renovation of supply air-conditioning system of k-4 and k5 with other accessories for rlg, barc, mumbai - design, fabrication, supply, installation, testing and commissioning of chilled water base double skin 10000 cfm ahu (without blower) as per clause no. 01 of technical specification., supply, fabrication and installation of ms supporting structures as per clause no. 02 of technical specification., design, supply, fabrication and installation of galvanized steel sheet for discharge air ducts as per clause no. 03 of technical specification., supply and installation of magnehelic gauge pressure range 0 to 25 mm wc including fittings as per clause no. 04 of technical specification., supply and installation of pressure gauges (0 to 7 kg/cm2 range) including fittings and ss ball valve as per clause no. 05 of technical specification., supply and installation of bar stock type ss thermowell with temperature guage as per clause no. 06 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 80 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 100 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 125 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, installation, testing & commissioning of 50 mm size cpvc pipe with fittings as per clause no. 08 of technical specification., supply, installation, testing and commissioning of 100 nb mm dia flange ended gate valve ( ci body and gun metal internal)with suitable fittings and counter flanges for pipelines as per clause no. 09 of technical specification., supply, installation, testing and commissioning of 80 nb mm dia flange ended gun metal gate valve with suitable fittings and counter flanges for pipelines as per clause no. 9 of technical specification., supply, installation, testing and commissioning of 80 nb mm dia globe valve with suitable fittings and counter flanges for pipelines as per clause no. 10 of technical specification., supply and installation of all-around cold insulation saddles for chilled water pipeline along with fixing fittings as per clause no. 11 of technical specification., supply and installation of aluminium construction powder coated air diffuser along with volume control damper as per the clause no. 12 of the technical specification., supply and installation of 38 mm thickness close rubber cell cold insulation of classo fire rating followed by aluminium clading as per clause no. 13 of technical specification., supply, fabrication, installation and commissioning of the ss structural material including ss hardware. as per clause no 14 of technical specification., fabrication, supply and installation of ss construction multilouvered volume control dampers (vcd) along with electricaly operated modulating type actuator as per clause no. 15 of the technical specification., supply, fabrication and installation of plenum connection to existing blower as per clause no 16 of the technical specification., dismantling, segregation, removing & shifting of various equipment like ahu, insulated pipes along with supports, fittings, valves etc. as per the clause no. 17 of the technical specification.
Tender For air cooled ducted 16.5 tr ac unit , air cooled ducted 5 tr ac unit , unloading lifting and shifting of 16.5 tr ducted package ac unit at site , unloading lifting and shifting of 5 tr ducted package ac unit at site , installation n2 pressure testing vacummising and commissioning of 16.5 tr ac , installation n2 pressure testing vacummising and commissioning of 5 tr ac , supply and charging of r 410 gas , supply and inst of floor mounted ms stand fabricated out of ms channel , supply and inst of floor mounted ms stand fabricated out of ms angel , hard copper refrigerant piping between indoor and outdoor units , supply and installation of gss ducting as 24g , supply and installation of gss ducting as 22g , acoustic insulation of plenum initial ducting with 10mm thick armasound , supply and fixing of 13mm thick nitrile rubber al foil faced insulation class i , supply and installation of ai powered jet nozzles with volume control damper , supply and inst of ai powered return air grills without volume control dampers , supply and installation of gi opposed blade duct dampers, qty 1.5 sqmtr , supply and fixing of canvas connection , supply and laying of 32mm dia pvc drain piping , electrical cabling 6 c x 1.5 sqmm cu flexible , electrical cabling 3 c x 1.5 sqmm cu flexible , electrical cabling 1 sqmm cu flexible double earthing * /bid number : gem/2026/b/7581741 + /dated: 11-06-2026 ' ' / bid document 1 / 24
Tender For bid to ras bid to ras supply of ductable ac 8.5 tr , refrigerant piping as above for 8.5 tr machine , drain piping 25 mm dia , supply and fabrication of ms structure to support the machine, outdoor and ducting , control cable , power cable 4c x 6 sqmm , power cable 4c x 50 sqmm , ms cable tray 50 x 100 x 50 x 1.6 mm , 22g oval ducting , supply of fire-retardant flexible canvass connections , supply of anodized extruded aluminium supply air double louver grills with volume control damper , supply of electrical panel with 1 no suitable capacity incomer and 6 nos suitable rating outgoing feeder for ductable units , providing of outdoor stands duly painted , providing of ss 304 drain tray under the ductable units , supply of portable air conditioner capacity 1 tr , installation testing and commissioning charges , freight charges including packing forwarding, transportation, insurance and unloading of material
Tender For maintenance of various e&m services at igi stadium complex, new delhi during 2026-27 (sh- replacement of soft starter with variable frequency drive (vfd) and provision of volume control damper (vcd) at kdjw stadium).subwork/packages:replacement of soft starter with variable frequency drive (vfd) and provision of volume control damper (vcd) at kdjw stadium