Web Analytics Made Easy - StatCounter

Air Conditioning System Tenders

Get complete information related to latest Air Conditioning System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Conditioning System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Conditioning System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45734804 Due date: 13 Jul, 202613 Jul, 2026 79.72 Lacs
Tender For augmentation of air conditioning system in rooms of hsvp office building sector-3, rohtak including one year defect liability and maintenance free of cost.

Central Government/Public Sector

CTN :45736636 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of air brake 'u' clamp for 20mm bore pipe with 2 no m10 hexagonal nut & spring washer inassembled condition to drg. no.icf/wgscn/c-3-5-005 item 10, 12 & 13 alt 'm' [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45733179 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For auction sale of depot ferrous scrap - ubl/gsd/c-0031/air filter /26/c [pl no.98412164] condemned and un- serviceable air filter scrap consisting of air filters, lhb fresh air filters, return air filters, inner air flitters and outer air filters vehicle air filter, forklift fuel/lube oil filters, demu bypass oil/lube oil filters ,compressor air/oil filters, dynacell filter, filter parts, air filter of 1400hp demu dpc cummins, outer /inner air filters, catepiller outer/inner air filters and other similar scrap, in different condition with or without ms/ss/aluminum/cloth/paper attachments . available under the custody of cdms/rs ward/gsd/ubl. note: purchaser has to physically inspect the lot before bidding.location: road no -02 gsd/ubl bin no-block: c-031. remarks-. delivery should start from one end. no pick and choose allowed.

State Government

CTN :45744871 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For hiring of maxi cab (non- air condition, bharat stage iii on or after 01/05/2008 with diesel / lpg/cng engine) in perfect good running condition of performing a very long journey and should be covered without any trouble on daily hire basis for official use for the office of the assistant engineer, jangipur sub division, p.h.e dte. n.b: 1. vehicle shall not be used other than departmental works and must be placed in every month otherwise deduction to be made pro-rate basic. 2. fuel @ 1 ltr per 10 km for maxi cab and mobil oil @ 5 ltr per 2500 km will be allowed. 3. all other rules & regulation have to be maintained according to latest gazette and govt. order. 3564-wt/3m-81/98 dated-24/11/2008.

Central Government/Public Sector

CTN :45730349 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For quotations for replacement & supply, installation, testing & commissioning (sitc) of 10 hp outdoor unit (make diakin, model rxmq10) of vrv air-conditioning system under buy back offer at dit powai

State Government

CTN :45741651 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - pw-95g (tmd-6) annual maintenance contract of voltas make chiller plant and other related auxiliaries of air conditioning system installed at 500mw unit no-6 of ukai tps; as per schedule b and ..

corporations/Associations/Others

CTN :45723624 Due date: 02 Jul, 202602 Jul, 2026 6.00 Lacs
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe

State Government

CTN :44918719 Due date: 04 Jul, 202604 Jul, 2026 95.2 Thousand
Tender For corrigendum : providing complete comprehensive maintenance of vrv air conditioning system in city civil court, secunderbad for the year 2026-27

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
 Loading, Please wait...

Connect us via What's Up