Get complete information related to latest Air Control Gauge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Control Gauge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Control Gauge Tenders.
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For reer tender notice - purchase of non consumable item in thermal lab for mechanical department - open type air conditioning system kitcode - (d030)1.5 ton1. compressor type:open type capacity:0.5 tr to 1tr power 1 hp supply 230 v,single phase 50 hz2.condenser type: air cooled condenser material : copper tube with aluminium fins fan motor:230 v ac3.evaporator type :open fin type material : copper air circulation : blower assisted mounted openly for observation4. blower/fan type: centrifugal blower air flow : adjustable power:230 v ac5. refrigeration type : r226. measuring instruments pressure gauges: low&high pressure temperature:thermometers,digital sensors voltmeter : 0 to 300 v ammeter : 0 to 10 a temperature display : at inlet and outlet points energy meter: single phase, exhaust gas analysercode - (d037)to find the percentage of co,co2, o2, amount of hc and nox using exhaust gas analyzer. afr and lammda are measurable.
Tender For supply of pressure gauges and temperature gauges : : - pg 0 to 10 kg , pg 0 to 25 kg , pg 0 to 40 kg , pg 0 to 100 kg , tg 0-200degc , tg 0-200 c , tg 0-400 degc , tg 0- 600 degc
Tender For corrigendum : procurement of oil module and its mandatory spares for 1x800 mw yamunanagar project - motor terminal block ac aop motor , motor terminal block for ac jop motor , motor terminal block for ac ove motor , "motor terminal block for dc eop motor (1 set = 2 nos.)" , "motor terminal block for dc jop motor (1 set = 2 nos.)" , "space heater for ac aop motor (1 set = 2 nos.)" , "space heater for ac jop motor (1 set = 2 nos.)" , "space heater for ac ove motor (if not applicable then space heater for acjop to be provided) (1 set = 2 nos.) " , "space heater for dc eop motor (1 set = 2 nos.)" , "space heater for dc jop motor (1 set = 2 nos.)" , bearings for motor for lube oil pump (aop) , bearings for motor for acjop , bearings for oil vapour exhauster motor , bearings (de and nde) for dc eop motor , bearings (de and nde) for dc liop motor , carbon brushes for dc eop motor , carbon brushes for dc jop motor , brush assemblies for dc eop motor , brush assemblies for dc jop motor , ac motor for lube oil pump (aop) , ac motor for lifting oil pump (jop) , oil vapour exhauster motor , dc eop motor , dc liop motor , lube oil tcv actuator , lt for oil module –m(850-1750 mm) , pressure switch index-d (0.5 - 10 bar) , dp transmitter lube oil filter , rtd (0 to 100°c) for oil module , level gauge for oil module , local gauges (0-10 bar) -oil module , local gauges (0-400 bar) -oil module , pressure gauge ((-)120-0 mbar) -oil module , temperature indicator (0-100 degc) , pr. transmitter range (0-250 bar)-oil mod , pr. transmitter range (0-6 bar)-oil mod , pr. transmitter range (0-(-120) mbar)-oil mod
Tender For providing of custom bid for services - replacement of thrust bearing of unit#1 and checking and replacement of upper guide, lower guide of unit#1 & turbine guide bearing of unit#1&2 along with installation of bearing temperature gauges, lube oil cleaning/filtrati..
Tender For purchase of non consumable item in thermal lab for mechanical department - open type air conditioning system kitcode - (d030)1.5 ton1. compressor type:open type capacity:0.5 tr to 1tr power 1 hp supply 230 v,single phase 50 hz2.condenser type: air cooled condenser material : copper tube with aluminium fins fan motor:230 v ac3.evaporator type :open fin type material : copper air circulation : blower assisted mounted openly for observation4. blower/fan type: centrifugal blower air flow : adjustable power:230 v ac5. refrigeration type : r226. measuring instruments pressure gauges: low&high pressure temperature:thermometers,digital sensors voltmeter : 0 to 300 v ammeter : 0 to 10 a temperature display : at inlet and outlet points energy meter: single phase, exhaust gas analysercode - (d037)to find the percentage of co,co2, o2, amount of hc and nox using exhaust gas analyzer. afr and lammda are measurable.