Web Analytics Made Easy - StatCounter

Air Dehumidifier Tenders

Get complete information related to latest Air Dehumidifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Dehumidifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Dehumidifier Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45679372 Due date: 02 Jul, 202602 Jul, 2026 20.16 Lacs
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)

Central Government/Public Sector

CTN :45681634 Due date: 24 Jul, 202624 Jul, 2026 NA
Tender For supply of set of breather / air dehumidifier for tfp & traction converter of wag-9 locomotive. one set comprising of 02 items in 02 nos. as per sketch no.els/aq/wag-9/sk.no.0078, rev %u201c1%u201d [ warranty period: 30 months after the date of delivery ] ]

CTN :45546464 Due date: 18 Aug, 202618 Aug, 2026 NA
Tender For corrigendum : supply of set of breather/air dehumidifier for tfp & traction converter of wag9 locomotives, one set comprising of 02 items in 02 nos. sketchno. els/aq/ wag-9/sk.no.0078 (rev.-0) 1- air humidifier, abb drg./idno. hstn-422090/3 eh00410115p001, clw spec. no. clw/es/3/0456 , qty./set - 01 no. 2- breather type em3ma, abb drg./idno.hstn- 422029p0001/ 12ch100120, clw spec. no. - clw/es/3/0456 , qty./set [ in nos.] - 01 [ set comprising of 02 items in 02nos./set) [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45486804 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of breather/air dehumidifier for 7775/6531 kva main transformer of 3 phase locomotive, technical data-em3 ma and abb id no. hstn 422029 p0001. material to be procured fromsupplier to oem of 7775/6531 kva main transformer with recent purchase proof of same item/supplier to clw or other railway with recent purchase proof of same item [ warranty period: 30 months after the date of delivery ] ]

CTN :45112925 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

Central Government/Public Sector

CTN :44393893 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For bid to ras supply of transformer oil filtration and dehydration plant capacity 6000lph as per specification attached.

Central Government/Public Sector

CTN :45431063 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For auction sale of depot miscellaneous scrap - 98325061scrap condemned machine consisting of oil filternation and dehydration plant capacity 225 lph total = 01 nosnote: - private crane allowed for easy loading purpose.

CTN :45396584 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For supply of breathers/air dehumidifier for 7775/6531 kva main transformer of 3 phase locomotive, technical data - em3ma & abb id no. hstn 422029 p0001. material to be procured fromclw approved sources of main transformerof 3 phase locomotive or oem of main transformerof 3 phase locomotive or oem of breather of main transformer of 3 phase locomotive only. make:- yogya or similar. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45017387 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For corrigendum : tggenco-ytps(5x800mw)-supply of spares consumables and accessories for main turbine hydraulic power supply units of unit-1 and 2 of ytps. - axial-piston pump, a a10vso 45 drg /31rvpa12n00,, main turbine hpsu, rexorath make, main turbine hpsu c f pump coupling,, ab33-22/kd 42-25/48, rexorath make, p r v for c f pump, dbds6g1x/315v,, rexorath make, p r v for c f pump header, dbds 20, k1x/315v, rexorath make, c f pump dischage hy-check valve m-sr 15, ke05-1x/v rexorath make, pressure measuring coupling, mcs20-, sds-e-g1/4-st3n00z-m, rexorath make, main turbine hpsu accumulator shut-of, block, eca32-01-v-n-8h, rexorath make, return line hy-check valve, s30a1.0/,, rexorath make, recirculation internal gear pump, pgf3-, 3x/032re07ve4, rexorath make, regeneration gear pump, 00c0.25x033,, rexorath make, recirculation pump coupling, ab33-22/kd, 24-25/28-98, rexorath make, recirculation pump hy-check valves,, 20a1.0/, rexorath make, throttle valve ndve-dn8-g1/2-18,, rexorath make, regeneration hy-check valve, m-sr 8, ke05-1x/v, rexorath make, cooler return filter, 25te0101-, 2x/pwr10e00-b2,2-v-r4, rexorath make, chemicals molekularsiebe 4a, rexorath, make, chemicals amberlyst a21 resin, rexorath, make, air dehumidifier, fpe-bo-re-07-g1 1/2 x g 3/4, tank aeration filter, bfs 20 h10xl-f00

Central Government/Public Sector

CTN :44811848 Due date: 19 May, 202619 May, 2026 NA
Tender For corrigendum : spares for bry air dehumidifier model ba 3a for generators at faridabad
 Loading, Please wait...

Connect us via What's Up