Web Analytics Made Easy - StatCounter

Air Dryer Spares Tenders

Get complete information related to latest Air Dryer Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Dryer Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Dryer Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45733981 Due date: 18 Jul, 202618 Jul, 2026 35.00 Lacs
Tender For repair maint of solar water heating system including replacement of u s connected items at ahrr under ge e m rr hospital delhi cantt-10

Central Government/Public Sector

CTN :45505307 Due date: 07 Jul, 202607 Jul, 2026 8.84 Lacs
Tender For corrigendum : provn of hot water appliance and solar water heating system for rr camp under age reasi of ge nagrota

corporations/Associations/Others

CTN :45587799 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : providing of operation and maintenance of hvac system (heating, ventilation and air conditioning system) - complete system

Central Government/Public Sector

CTN :45739552 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For providing of operation and maintenance of hvac system (heating, ventilation and air conditioning system) - complete system

CTN :45343823 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : annual operation and maintenance contract of solar water heating system installed at aiims campus bhopal.

CTN :45733165 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For auction sale of depot non ferrous scrap - lot no.p.nfa-1.bin no- 2/a ,7/a & ground floor at near bin -37.exmp.06.2026-27.03 description- scrap aluminium with iron attachment, and other aluminium casting, field coil, lamp caps, aluminium boring etc. our offer: a) scrap aluminium with or without iron attachment. such as- scrap aluminium cylinder for tap changer, aluminium number plate, aluminium feeder wire, steady arm, anti wind clamp, wiper motor, bus bar connector (aluminium), part of filter element of emu motor coaches, compressor & air dryer spares, horn, gauge cover, piston sub assembly, and other aluminium misc.as in the lot which are kept in bin no-2/a & ground floor of near bin 37. qty= 1929 kgs. b) scrap aluminium rear & front cover with or without rubber and grease attachment. in bin no- 7/a . qty- 2462 kgs. loading will be done by purchaser's own arrangment.

CTN :45570164 Due date: 03 Jul, 202603 Jul, 2026 13.27 Lacs
Tender For corrigendum : supply, installation, testing and commissioning of water heating system in dhauladhar and yamuna hostel at nit delhi

CTN :45713045 Due date: 13 Jul, 202613 Jul, 2026 1.70 Lacs
Tender For supply of boiler plant job work automatic drum level control system of boiler no 1 2 and 3 complete penal overhauling calibration and recommissioning , re wiring of multichannel temp. monitoring laying of temp compensating cable jo fixing of temp series and recommissioning of panels , power turbine pannel job work repairing, calibration of digital temp jo monitoring panel avr acb for power turbine pannel and re wiring of the complete panel and its recommissioning , boiling house job work repairing, overhauling, complete re wiring and recommissioning desuper heating system in the exhaust line sto automatically control temp , repairing overhauling and recommissioning automatically control system jo super heated wash water for c by f machine , repairing and calibration of temp monitoring panels for rj by sj by inj c and exhaust steam and its commissioning after laying cable and fixing temp sensor * /bid number : gem/2026/b/7717241 + /dated: 27-06-2026 ' ' / bid document 1 / 11
 Loading, Please wait...

Connect us via What's Up