Get complete information related to latest Air Duct Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Duct Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Duct Tenders.
Tender For supply of set of return airduct complete for ac 3t amrit bharat coaches. follow colour scheme as per design l.no. md48161 dated 15.05.2026., as per drawing: mplrad3tab version 0, packing instruction: frp ceiling sheet/side wall panels/frp component self adhesive biodegradable plastic lamination sheet to be provided on each component. projected metallic parts to be protected with plastic/nylon/frpcaps/proper wrapping of biodegradable bubble sheet from all the sides. each component to be packed in biodegradable bubble sheet all around with proper tapping & then to be placed in cardboard box followed by 3 nylon strips tightened from both sides. then collective packs of components to be packed in wooden cage made from wooden strips of size 100x20mm & gap between each strip should not be more than 100mm.on the wooden crate base 3 wooden pegs of size100x100mm (along the length) to be provided for ease in handling with fork lifter.all loose items of a set to be packed separately in cardboard box with list of loose items pasted on each box and collective packs of item to be packed in wooden cage made from wooden . roof ceiling (having curved surfaces) in addition to above packing should be stacked on a metallic frames before packing in the wooden boxes. one package should not contain material belonging to more than one coach set & grouping should bepreferably of similar sizes. also packing should have indication like 1/4,2/4 etc. ( e.g. four packings will make one coach set) so that one complete coach set can be easlyidentified. the maximum weight of the wooden crate should not be more than 200 kgs. alist should be pasted on each wooden crate showing order no, pl no. description of item,drg no/spec no/set list no. with version, qty, firm's name & address,date of despatch etc. [ warranty period: 84 months after the date of delivery ] ]
Tender For spare parts for scania veh - ventilation glass v part no 206415, door glass part no 206957, door handle, outer v part no 227855, door handle, outer h part no 227856, lock v part no 1864792, control v part no 187721, control h part no 187722, ball part no 236177, side glass part no 256680, rear glass part no 256682, hydraulic pump part no 361453, wiper arm part no 1105172(255837), air nozzle part no 268387, airduct left part no 195669, airduct right part no 257104, fan motor(cab heater) part no 242395, closing plate lock part no 285093, window panes left part no 285070, adjusting angle connect part no 562579, nipple part no 562564, rubber protection part no 562608, nipple m8 part no 562617, pkv part no 562625, 28 spool control module part no 2530720477383(5626, selector valve part no 562631, hydraulic pipe part no 562648, switch part no 562656, motor part no 562464, extre man boom part no 562486, level indicator part no 562551, hydraulic pipe part no 562647, solenoid 24v part no 562520, rope guide roll rear part no 261389, bolt mc6s10 x 25 part no 809826, earth cable 430 mm part no 308080, safety valve part no 562626, solenoid valve part no 1115802(350127), junction box part no 583038, regulation arm / shock absorber part no 1104743
Tender For supply of airduct covering plate for hhp actm as per drg no 4/plw/m/tm-sk-127 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply and installation of scoop inside main airduct of vande bharat coaches to ensure uniform distribution of conditioned air in passenger saloon area as per cai no. a-2025/09. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of one coach set of tm duct (below under frame) for memu/dmc/3ph coaches consist of: (a) ss tm duct fixing arrgt (driving end) to drg.no.745-9-0-008, alt-a,which includes:1) ss airduct-1 at driving end to drg.no.745-9-0-004, alt-nil = 1no. 2)ss airduct-2 at driving end to drg.no.745-9-0-009, alt-nil = 1 no. and (b) ss tm duct fixing arrgt (non driving end) to drg.no.745-9-0-012,alt-a which includes : 1)ss airduct- 3 at non driving end to drg.no.745-9-0-006, alt-nil = 1 no. 2)ss airduct- 4 at non driving end to drg.no.745-9-0-011, alt-nil = 1 no. with adhesives given in the drg. packing instruction: pi012. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For supply of set of return airduct for wjcc coaches of bangladesh railways., as per drawing: mplradblwjcc version 1, packing instruction: frp ceiling sheet/side wall panels/frp component self adhesive biodegradable plastic lamination sheet to be provided on each component. projected metallic parts to be protected with plastic/nylon/frpcaps/proper wrapping of biodegradable bubble sheet from all the sides. each component to be packed in biodegradable bubble sheet all around with proper tapping & then to be placed incardboard box followed by 3 nylon strips tightened from both sides. then collective packs of components to be packed in wooden cage made from wooden strips of size 100x20mm & gap between each strip should not be more than 100mm.on the wooden crate base 3 wooden pegs of size100x100mm (along the length) to be provided for ease in handling with fork lifter. all loose items of a set to be packed separately in cardboard boxwith list of loose items pasted on each box and collective packs of item to be packed inwooden cage made from wooden . roof ceiling (having curved surfaces) in addition to above packing should be stacked on a metallic frames before packing in the wooden boxes. one package should not contain material belonging to more than one coach set & grouping should be preferably of similar sizes. also packing should have indication like 1/4,2/4 etc. ( e.g. four packings will make one coach set) so that one complete coach set can be easly identified. the maximum weight of the wooden crate should not be more than 200 kgs. a list should be pasted on each wooden crate showing order no, pl no. description of item,drg no/spec no/set list no. with version, qty, firm's name & address,date of despatch etc. [ warranty period: 30 months after the date of delivery ] ]