Web Analytics Made Easy - StatCounter

Air Ducting Tenders

Get complete information related to latest Air Ducting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Ducting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Ducting Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45527664 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of cleaning maintenance and overhauling of various lt mcc generator phase and neutral links generator bus duct excitation transformer lavt and..

Central Government/Public Sector

CTN :45733949 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For repair maintenance for air flow duct internal electrification etc at 6 afh pocket c and echs

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

Central Government/Public Sector

CTN :45711103 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.

Central Government/Public Sector

CTN :45365822 Due date: 06 Jul, 202606 Jul, 2026 39.99 Lacs
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches

State Government

CTN :45685997 Due date: 10 Jul, 202610 Jul, 2026 4.65 Lacs
Tender For repair to the existing cable duct in the station yard and other allied works at 220kv r/s sedam.

Central Government/Public Sector

CTN :45486097 Due date: 30 Jun, 202630 Jun, 2026 12.00 Lacs
Tender For corrigendum : repair / maint of split / window air conditioning, desert coolers, air ducting coolers, refirigerator, water coolers at fort area nagpur under ge kamptee.

corporations/Associations/Others

CTN :45649100 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; overhauling maintenance of hot air duct (bypass air, inlet air, mixing box), cold air duct (purge air) and various pipes connected to ball mill (bbd..

Central Government/Public Sector

CTN :45289817 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For corrigendum : repair maintenance for air flow duct internal electrification etc at 6 afh pocket c and echs

CTN :45605434 Due date: 17 Jul, 202617 Jul, 2026 19.18 Lacs
Tender For supply, fabrication and erection, testing, and commissioning (etc) work of louvers, dampers and repair/ reconditioning work of damaged duct of existing air washer (evaporating cooling system) for unit i to vii at kstps, kota
 Loading, Please wait...

Connect us via What's Up