Get complete information related to latest Air Filter Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Filter Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Filter Panel Tenders.
Tender For bid to ras corrigendum : supply of filter , supply- ac and ventilation system- air intake louver , supply- ac and ventilation system- gravity damper , supply- ac and ventilation system- axial flow supply fans- 5500 cmh , supply- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , spares- ac and ventilation system -v-belt for ahu blower of each type , spares- ac and ventilation system -ahu blower bearings of each type , spares- ac and ventilation system -blower motor bearing for ahu , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system - geyserstat , spares-ac and ventilation system- local humidity temperature indicators , etc- ac and ventilation system- air cooled dx type condensing unit- minimum 33 tr actual capacity , etc- ac and ventilation system- air handling unit- ahu , etc- ac and ventilation system- fresh air fan assembly , etc- ac and ventilation system- split ac unit - 2 tr , etc- ac and ventilation system- strip heaters , etc- ac and ventilation system- pan humidifier , etc- ac and ventilation system- copper refrigerant piping- suction line , etc- ac and ventilation system- copper refrigerant piping-liquid line , etc- ac and ventilation system- refrigerant gas , etc- ac and ventilation system- gss duct sheet-24 g- air conditioning system , etc- ac and ventilation system- gss duct sheet-22 g- air conditioning system , etc- ac and ventilation system- gss duct sheet- 20 g- air conditioning system , etc- ac and ventilation system-gss duct sheet- 18 g- air conditioning system , etc- ac and ventilation system-non return damper , etc- ac and ventilation system-volume control damper , etc- ac and ventilation system- fire damper , etc- ac and ventilation system- motorised actuator for fire damper , etc- ac and ventilation system- grills diffusers , etc- ac and ventilation system- accoustic insulation , etc- ac and ventilation system- thermal insulation , etc- ac and ventilation system- dp switch , etc- ac and ventilation system- air flow switch , etc- ac and ventilation system- temperature cum rh sensor , etc- ac and ventilation system- fine filter , etc- ac and ventilation system- air intake louver , etc- ac and ventilation system-gravity damper , etc- ac and ventilation system- axial flow etc fans- 5500 cmh , etc- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , etc- ac and ventilation system-cable laying and termination alonwith lugs glands and any other accessories
Tender For bid to ras tender for supply of split airconditioner at certain locations at af stn rajokri : - supply install testing and commissioning of energy efficient hi wall split type airconditioner with indoor and outdoor unit complete with inverter technology 3d airflow power chill operation cordless remote control unit and with in built air ioniser pm 2 5 filter for better indoor air quality with 5 star rating and eer 3 2 of capacity 1 5 tr with precharged cfc free refrigerant including drain pipe copper tubings of suitable dimensions cutting the holes and making good the disturbed surface with existing colour all as specified and directed by engr in charge note 1 cost of outdoor unit stand shall be included in quoted rate 2 all units shall be made of copper tubes 3 ac shall be designed to sustain 50 degree celcius outside temperature make daikin hitachi ogeneral , s and f in replacement sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one double pole mcb 20 amps for geyser ac complete all as specified and as directed , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of pluse minuse 2 5 persent and of capacity 4 kva complete all as specified and directed , s and f of sub main wiring with pvc insulated frls unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4 sqmm nominal area drawn in and including concealed pvc conduit of suitable size as directed with and including one run of 4 sqmm multi stranded copper conductor single core pvc insulated unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed note two runs of 4 sqmm cable and one run of 4 sqmm cable of earth continuity conductor and conduit shall be a unit length , s and f of copper pipe 10 15 mm dia for indoor to outdoor connection complete all as specified and directed
Tender For supply of refrigerant gas rs 22,airfilter,single phase connector,copper pipe,reverse valve,installation of items deployed in active counter insurgency area
Tender For providing and fixing of spare parts pressure testing and allied works of 26 tr screw chiller machines installed at punjab engineering college sector 12, chandigarh. - sitc charges towards pressure testing of 26 tr scrool chiller compressor through n2, aftter pressure testing vaccumizing of system, leakes rectification if any, refrigerant charges and recommissioing of chiller complete in all respect to the entire satisfaction of eic., topping of refrigerant r-407 in chilling machine of capacity 26 tr complete in all respect., providing & fixing of temperature sesnor as per oem machine standard complete in all respect, de-scalling of 26 tr chiller condenser including cost of coil clean chemical, mechanical cleaning of tubes i.e brushing of individual tube with opening of end cover one side. the work includes the cost of nuts & bolts, gaskets including cleaning of floor area to entire satisfaction of eic., providing & fixing of filter drier as per machine specifications compete in all respect., providing & fixing of flow switch as per machine specifications compete in all respect., providing & fixing of pressure gauge with syphon and valve as per oem machine standard complete in all respect., providing & fixing of thermometer as per oem machine standard complete in all respect., sitc of ahus filter for all ahus compete in all respect., servicing of ahu coil along with the chemical through jet pump and combing as per site requirement, providing & fixing of cooling tower fins along with nozzles complete in all respect, providing & fixing of contactor of ahu panel as per panel standard complet in all respect, providing & fixing of overlaod relay of ahu panel complet in all respect
Tender For supply of air dryer spares and air study : : - r404a refrigirant ga 10kg , r410 a refrigerant 2 kg , hp switch 43bar solder , filter dryer liquid , kit replace 2202744001 , motor fan 300 v230 , filter dryer 30gr , electr drain ld202t , switch on off 23a , kit ctrl 230v , hpc compressor , r507a refrigerant 7 kg , dryer filter , air study
Tender For supply of potable water purification system with inbuilt water cooler. specifications as per - storage ca pacity (in litre)-80 , cooling capacity, ltr/hr-50 , purification capacity, ltr/hr-50 , warranty of compressor-3 years ,warranty of machine- 02 years ,water filter type- ro & uv based. ,condenser material- copper ,cert ification- iso ,refrigerant- r134a, number of faucets- 02 ,storage tank material- stainless steel 304, body material- ss304 , number of free services during warranty-02 firm offered make /brand - usha/ voltas/a quagurd or similar [ warranty period: 30 months after the date of delivery ]
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil