Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty airfilter 15 to 30 kva , replace heavy duty airfilter 32.5 to 40 kva , replace heavy duty airfilter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty airfilter 15 to 30 kva , replace heavy duty airfilter 32.5 to 40 kva , replace heavy duty airfilter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty airfilter 15 to 30 kva , replace heavy duty airfilter 32.5 to 40 kva , replace heavy duty airfilter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For bid to ras corrigendum : supply of house assy , f house , house water , house , o ring , clamp house , house air cleaner , house clamp , house elbow , gasket , air cleaner , element inter , element outer , dip stick , fuel filter , cap vandalism , air breather assy , house fuel supply , house fuel drain , nut , by pass filter , elementfilter , instrument panel , ammeter , wire harness , cable assy , clamp , screw , foot dimmer switch , grommet , pressure switch , terminal batery , cap small , head lamp , turn singhle lamp , fuse box
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109
Tender For bid to ras supply of coducter complete set with all accessories , pvc armoured cable 16 sqmm 4 core make havells comma finolex comma polycab , mcb box 8 way make l and t comma usha comma cg , recess mounting light 2 x 2 make bajaj comma crompton comma philips comma cg , ceiling fan 1200 mm sweep make bajaj comma usha comma cg comma khaitan , ms hook 12mm rod for fan , led tube light 20 watt 4ft complete make bajaj comma usha , led bulb 10 watt make philips comma anchor comma bajaj , exhaust fan 300 mm make philips comma anchor comma bajaj , mcb 63 amp make philips comma anchor comma bajaj , mcb 40 amp make philips comma anchor comma bajaj , mcb 5 to 30 amp make philips comma anchor comma bajaj , mcb 16 amp make philips comma anchor comma bajaj , cooler motor 6100rpm desert cooler 450mm make philips comma usha comma bajaj , desert cooler motor make philips comma usha comma bajaj , desert cooler water pump make philips comma usha comma bajaj , ceiling rose , pvc cable xlpe 25 sqmm 4 core make havells comma finolex comma polycab , led tube light fitting 10 watt 2 ft complete make bajaj comma usha , switch socket combination 15 amp make anchor comma bajaj , switch socket combination 5 amp make anchor comma bajaj , desert cooler 6100rpm make philips comma usha comma bajaj , switch 15 amp modular type make bajaj comma philips comma siemens comma anchor comma equivalent isi marked , bulk head fitting make philips comma bajaj , pvc swithc board 7 inch x 4 inch make anchor comma bajaj , pvc swithc board 10 inch x4 inch make anchor comma bajaj , socket 15 amp make anchor comma bajaj , flood light 100w make philips comma bajaj , security light 100w make philips comma bajaj , ro membrane for 1000lph make adelino comma leo comma cg comma kirloskar , fuel filter for 62 point 5 kva make kirloskar , oil filter for 62 point 5 kva make kirloskar , fan belt for 62 point 5 kva make kirloskar , oil temp guage for 62 point 5 kva make kirloskar , oil pressuer guage for 62 point 5 kva make kirloskar , exhaust fan for 62 point 5 kva make kirloskar , fuel guage for 62 point 5 kva make kirloskar , battery 12 v150 ah make exide comma amaron , engine oil make castrol , fuel filter for 30 kva make kirloskar , oil filter for 30 kva make kirloskar , fan belt for 30 kva make kirloskar , airfilter paper type for 30 kva make kirloskar , panel box repair make kirloskar , alternator winding 62 point 5kva make kirloskar , router winding 62 point 5kva make kirloskar , excider winding 62 point 5kva make kirloskar , avr card make kirloskar , diode make kirloskar , starter motor repair make kirloskar , flywheel ring gear make kirloskar , fuel pipe make kirloskar , alternator winding 30kva make kirloskar , rotor winding 30kva make kirloskar , exciter winding 30kva make kirloskar , change over switch 100amp , submersible pump rewinding , change over switch 64amp
Tender For bid to ras supply of aluminium armoured cable , gi perforated cable trays 100 mm wide x 50 mm depth x 1point 6 mm thickness , raceway 150 mm wide x 50 mm depth x 1 point 6 mm thickness , switch socket 6 modular box 16 amp switch socket 6 amp , providing and laying cat 6 6 pair cable with accessories , supply and fixing of 4 way tpn horizontal db box with accessories , supply and fixing of 63 amp isolator , supply and fixing of 63 amp rccb , supply and fixing of 16 amp mcb , supply and fixing of 40 amp rccb , supply and fixing of 100 amp isolator , supply and fixing of 100 amp rccb , scaffolding , sitc of ups 20 kva with isolation transformer , sitc of 2x2 clean room luminaries , dismantling aluminium gypsum partitions doors windows fixed , dismantling tile work in floors and roofs 10 25 mm thick , cement concrete flooring 124 mix 40 mm thick , modular walls with 60 mm thick puf panels , modular ceiling with 60 mm thick puf panels , epoxy flooring 5 mm thick , aac block masonry 150 230 300 mm thick , 12 mm cement plaster 1 4 mix , vitrified tile 600x600 mm , pvc flooring , plaster of paris putty 2 mm thick , wall painting with acrylic emulsion , granite stone slab for platforms , extra for granite facia drops , extra for openings in granite for sinks , reinforced cement concrete work , centering and shuttering for shelves , steel reinforcement for rcc , stainless steel kitchen sink 610x510 mm , cp brass waste coupling 32 mm , coat hook with bracket , 600 mm long towel rail , cp brass angular stop cock , cp brass bottle trap 32 mm , upvc connection pipe with brass unions , c p sink cock with regular swinging spout table mounted model , c p brass extension nipple 15mmx50mm , stainless steel cabinets under counter and overhead , storage cabinets under counter and overhead , hermetically sealed swing door 900mm w x 2100mm , hermetically sealed swing door 1500mm w x 2100mm h , flush door shutters isi marked non decorative 35mm thick , extra for lipping with teak wood battens 25mm minimum depth , extra for vision panel not exceeding 0 point1 sqm rectangular or square , laminated sheet , h type stainless steel pull handle 304 grade 25x600mm , aluminium extruded section body tubular type universal hydraulic door closer , pair design lever handle on roses and escutcheons with mortise sash lock , dgu glass 1200mm x 1400mm , pass box 580 x 650 x 700 mm id 1 , pass box 230 x 230 x 295 mm id 1 , aluminium work for fixed portions polyester powder coated 50 micron , aluminium shutters for doors windows , glazing in aluminium frames 5mm float glass , pre laminated particle board for panelling 12mm thick , removal and refixing mineral fibre false ceiling tiles 595x595mm , cpvc pipes 15mm nominal dia hot cold water , cpvc pipes 20mm nominal dia hot and cold water , cutting holes in rcc floors roofs up to 15x15cm for drain pipes , trap self cleansing 100mm inlet outlet sand cast iron s and s , trap self cleansing 100mm inlet 75mm outlet sand cast iron s and s , glazed stoneware pipes class sp 1 100mm 1 is1 cement mortar , demolishing cement concrete 136 or richer , cement concrete work up to plinth level 124 mix , square mouth sw gully trap class sp 1 100x100mm p type , corner coving , steel work in built up tubular trusses hot finished welded tubes , eye and face wash station floor mounted dx type double skinned ahu, air cooled outdoor vrf units, ahu connection kit, hepa filter plenum laminar air flow system, gi ducting for tb lab, indoor ducting thermal insulation, exposed ducting thermal insulation, acoustic insulation for ducting, ahu control unit //bid details 2 / 94