Web Analytics Made Easy - StatCounter

Air Pollution Control Machine Repair Tenders

Get complete information related to latest Air Pollution Control Machine Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Pollution Control Machine Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Pollution Control Machine Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42756414 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopaedia with a de

Central Government/Public Sector

CTN :42762971 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For supply and installation of nd-yag q-switched pulsed laser at iit bhilai - supply & installation of supply and installation of nd-yag q-switched pulsed laser at iit bhilai

CTN :41567143 Due date: 18 Nov, 202518 Nov, 2025 NA
Tender For bid to ras bid to ras supply of pulsed fiber laser marking system as technical specification annexure attached

CTN :42480926 Due date: 18 Nov, 202518 Nov, 2025 NA
Tender For supply of 300 microj, 1064 nm diode pumped solid state pulsed laser
 Loading, Please wait...

Connect us via What's Up