Tender For corrigendum : supply of vdc mv o p 4 20ma , digital energy meter connection 3 phase 3 wire ct ratio 10000 5 amp pt ratio 1575 kv 110 v50 hz acc class 2s make seccure apex 150 , transformer pt 415v 110v , portable digital megger test voltage , thermal o l relay mn2 4 2 to 7 5a , thermal o l relay 2 5 4 amp , dc clamp meter dc current 0 1a to 200a ac current 0 1a to 200a dc ac voltage 0 1v to 600v continuity data hold fa make motwane , control transformer t 1 input voltage 0 440v output s1 0 110 220 and s2 0 110 220 as per sample rating 50va , control transformer t 2 input voltage 0 440v output 0 18 24 as per sample rating 50va , heating element of esp hopper 0 5kw , transformer oil drum 210 lit , dehy breather for hvr transformer of esp , buchholz relay type gor 1 with alarm trip contact 1no plus 1nc , magnetic oil gauge with one tripping contact , prismatic oil level indicator size 150mmx60mm , glove valve size 25mm brass both side flange end , crc contact cleaner 300 ml cane , neoprene rubber sheet 1x2mtr thick 10mm , aluminium lugs 70sq mm als 226 e bolt hole 13mm make dowells , aluminium lugs 185 sq mm als 235 e bolt hole 17mm make dowells , aluminium lugs 120sq mm als 230 e bolt hole 13mm make dowells , aluminium ferrule 120sq mm make dowells , aluminium ferrule 150 sq mm make dowells , copper ferrule size 185 sq mm make dowells , copper ferrule size 120 sq mm make dowells , push button on off with element , hrc fuse3na 7805 orc 16 a make siemens , hrc fuse3na 7820 orc 32 a make siemens , mccbn 16r 150a 3p , ns type fuse 32 amp , ns type fuse6 amp , ns type fuse 25 amp , on delay timer 0 5 sec to 100 hours 24 240v ac dc , local remote switch 25a 440v brand kaycee siemens havell l t , voltmeter sel switchmodel srp1373way off , din type fuse rating 100 a , din type fuse rating 125 a , hrc fuse t a 32 rated for 32 amp code no sfb 8116032 , pin type insulator 0 4kv , petroleum jelly for battery , din type fuse hrc size 3 current rating 500 amp , rectifier fuses 150 amps semiconductor type , led indication lamp red yellow blue green 220v ac dc , dd module 236 amp 1000piv , dd module 260 amp 1600piv , dd module 70 amp 1000piv , mccb 150a 3 pole , motor cooling fan with cover for 2 2 kw gt cooling fan motor , control fuse ns type 2amp , control fuse ns type 4 amp , control fuse ns type 6 amp , din type hrc fuse 25a 415v ac size 00 , din type hrc fuse 32a 415v ac size 00 , din type hrc fuse 63a 415v ac size 00 , analogue ac voltmeter range 0 500v , analogue ac voltmeter range 0 500v ptr 415 110 v , analogue ac ammeter range 0 50 amp ctr 50 , dc voltmeter moving iron jewel bearing range accuracy , ammeter range 0 15amp ctr 15 1 , moving iron analog ac ampere meter ct ratio 400 5a d , d c ammeter moving coil range , ac ammeter range 0 25amp , aux contactor 2no plus2nc coil voltage 24v ac , aux contactor 3no plus1nc coil voltage 24v ac , switch disconnector fuse unit 2pole current carrying capacity 315 amp max operating voltage 600 v 50hz for one to one replacement , power contactor 3pole current carrying capacity 315amp max operating voltage 600v coil voltage 220 250vac 50hz dc for one to one replacement , local remote selector switch 10a model type 2s26b or equivalent for one to one replacement , ammeter rotary switch 12a r y b off 4 position 90 degree , voltmeter selector switch 12a ry yb br off , local remote selector switch 3 pole2 way without off 16 amp , tnc rotary switch 25amp spring return to neutral model type , switch //bid details 2 / 59 fuse unit 63a 3p , switch fuse unit 125a , thermal overload relay
Tender For supply of set of voltmeters consist of 02 items (1) voltmeter for battery voltage indication (position no.116) as per clw specification no. clw/es/3/0073 or latest and confirming to clw drg no. clw/es/3/sk1/0073 or latest-01 no. (2) voltmeter for catenary voltage indicator (position no.74.0) as per clw specificationno. clw/es/3/0070, alt- nil or latest and confirming to clw drg no. clw/es/3/sk1/0070 or latest - 01 no. firms offered item: stores to be supplied as per galaxy instrument drg. no. gi/rsq/14/06 date. march 2006 for battery voltmeter and gi/ew-s/13/06 date. march 2006 for catenary voltmeterapproved by clw/crj. (clw specn clw/ es/3/0073 for battery voltmeter. clw/es/3/0070 for catenaryvoltmeter) [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying, providing, installing and commissioning of smart real time gate position and auto pn system which includes 10.1" display module with touch screen for sm unit and lc unit, interactive ui to clearly display train number and gate position on the sm unit and lc units, 4g connectivity with fallback to 3g/2g where 4g network is not present, sensors to detect the position of lc gate boom and boom locking lever, sensors capable of interchangeable and also identify if the gate is locked. sensor shall have weather proof casing, lc unit interacts with sensors continuously to detect the position of gate boom/boom-locklever and generate auto - pn only when both the conditions satisfied i.e. boom is closed condition and leveroperated for boom locking. sm unit generates auto pn when sm enters train number, up/dn details. lc unit has auto pn generated when the gate is identified as closed and boom lock lever operated, after the sm command, lc unit shall report the status of the gate whenever changed its position and status of lc gate position on sm unit shall be indicated by red icon when gate is in open condition and that is by green icon when gate is in closed condition, sm unit and lc units are connected by wireless equipment. fail safe measures are also implemented along with backup and database from where each and every operation that isrecorded between the gateman and the station master, which can be viewed. the rate is including all tools,plants, labour, transportation, manpower including cost of cloud subscription and 4g/3g data plan for 1 year at contractor's own cost inclusive of all taxes as applicable. providing track indicator, lever lock arrangement with iot, and interlocking all the above with pn exchange so as to stop unauthorised opening of ctrt and otrt gates. with 1 year maintenance against all kinds of failures physical and functional, installation and operation. warranty on hardware minimum 2 years. any other modifications and addition as per engineers instructions. the execution of works for the non interlocked lc gates under sse/pway/bdo(from sr.no. 1 to 6) and under sse/p.way/cbsa (from sr.no. 7 to 12) are furnished in annxure- a (enclosed) [ warranty period: 30 months after the date of delivery ] ]