Get complete information related to latest Air Washer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Washer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Washer Tenders.
Tender For supply of railways carriage fan, swivel type, 110v ac, 400 mm sweep with crashworthy features as per rcf am-4 (ty-xiii) with stainless steel guard to drg.no. icf/sk-7-6-158., as per drawing: is:6680-92 with rdso annexure-h (revised december-2005) rcf corr-1,3 &4 & blade as specified at col- i of rcf am-4 with rubber packing as per drawing no. icf/sk-7-3-058, alt- 'e', item-1, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of service connector of 2.5 sq.mm cross section for connecting railway carriage fan and light fittings as per item no.wago make or equivalent as per the technical data: (1) type of wiring: side-entry wiring. (2) total number of connection points: 2. (3) total number of potentials: 1. (4) connection technology: cage clamp. (5) actuation type: push-in. (6) connectable conductor material: copper.(7) solid conductor: 0.5 - 2.5 mm 2/20 - 16awg. (8) fine stranded conductor: 0.5 - 2.5 mm 2/20 - 16awg. (9) strip length: 9 - 11mm/ 0.35 - 0.43 inch. (10) width: 8mm/ 0.315 inch. (11) height: 15.5mm/ 0.61 inch. (12) depth: 42 mm/ 1.654 inch. (13) colour: grey. (14) fire load (mj): 0.099 (mj). (15) weight(g): 5(g). [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of brushless dc (bldc) railway carriage fan complete with blade and gaurd confirming tordso specification. no. rdso/pe/spec/tl/0021/2005 (rev.3) with amendment no.1 with sweep as 400mm. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For supply of brushless dc (bldc) railway carriage fan complete with blade and gaurd confirming tordso specification. no. rdso/pe/spec/tl/0021/2005 (rev.3) with amendment no.1 with sweep as 400mm. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For auction sale of depot ferrous scrap - scrap junk kachra cut pieces of ms and gi sheet plate, pipes, filter, angle, flat, strip, rod, round, wire, coach cut parts, p.way items, tin, drums, gate lamp, cooler body, protective tube, oil filter, fan case, carriage fan jali, dust shield spring, ladder, fire extinguisher, bucket and other similar items of junk rusty, dusty with or without negligible non-ferrous attachment if any. [ bin38-39)
Tender For auction sale of depot ferrous scrap - scrap junk kachra cut pieces of ms and gi sheet plate, pipes, filter, angle, flat, strip, rod, round, wire, coach cut parts, p.way items, tin, drums, gate lamp, cooler body, protective tube, oil filter, fan case, carriage fan jali, dust shield spring, ladder, fire extinguisher, bucket and other similar items of junk rusty, dusty with or without negligible non-ferrous attachment if any. [ bin 17&opp bin 17)
Tender For corrigendum : work of preventive maintenance, shutdown & emergency maintenance of iac/sac compressor, airwashery fan/pump motor, acw/fcw motor of stage-2-wtps on as & when required basis.
Tender For tender for supply of mist eliminator : -mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -3 airwasher , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -3 airwasher. , suction filter frame as per attached specification and drawing for control building -3 airwasher , pump drain line with flanges and fittings as per attached specification sheet for control building -3 airwasher , pump suction line with flanges and fittings as per attached specification sheet for control building -3 airwasher , pump discharge line with flanges and fittings as per attached specification sheet for control building -3 airwasher , pump base frame as per attached specification sheet for control building -3 and control building -4 airwasher. , suction gate valve of size 100 nb as per attached specification and drawing for control building -3 and control building -4 airwasher , discharge globe valve size 80 nb as per attached specification and drawing for control building -3 and control building -4 airwasher. , suction strainer 100 nb as per attached specification and drawing for control building -3 and control building -4 airwasher , discharge non return valve -nrv- 80 nb as per attached specification and drawing for control building -3 and control building -4 airwasher. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -3 airwasher. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -3 airwasher , mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -4 airwasher. , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -4 airwasher. , suction filter frame as per attached specification and drawing for control building -4 airwasher , pump drain line with flanges and fittings as per attached specification sheet for control building -4 airwasher. , pump suction line with flanges and fittings as per attached specification sheet for control building -4 airwasher , pump discharge line with flanges and fittings as per attached specification sheet for control building -4 airwasher. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -4 airwasher. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -4 airwasher