Get complete information related to latest Airports Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Airports Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Airports Repair Tenders.
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109
Tender For supply of repair and maintenance of hand held search light , repair and maintenance of hand held metal detector , repair and maintenance of trail camera with accessories , repair and maintenance of bullet proof long tall morcha , repair and maintenance of veh mounted search light , repair and maintenance of bullet proof short morcha , repair and maintenance of under veh search mirror , repair and maintenance of portable tyre killer , repair and maintenance of ptz camera day and ni vision for cctv , repair and maintenance of adopter for cameras , repair and maintenance of camera poe cord , repair and maintenance of dc adopter for 17 poe switch , repair and maintenance of nvr repair , repair and maintenance of adopter for ote , repair and maintenance of ofc patch cords , repair and maintenance of utp drum , repair and maintenance of 12 v 7 ah bty for ups , repair and maintenance of junction box with mounting caps , repair and maintenance of power cable , repair and maintenance of terminal box , repair and maintenance of optical fiber cable
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For repair and maintenance of police post at truck terminal, narela (in compliance of monitoring committee observation under mou in the matter of society for awareness and development vs union of india and others).