Get complete information related to latest Alloy Wheels Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Alloy Wheels Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Alloy Wheels Tenders.
Tender For auction sale of depot ferrous scrap - scrap ferrous melting light melting consisting of coach cutting parts, window& seat bearth-frame, wire & wire rope, battery box, dust sheld spring, hand barrow off sizes, m.s & g.i. pipes & g.i sheet(plane/corrugated),brake shoe-head,brake beam,gear case, brake shoe &side frame key,slack-adjuster,nut, bolt, pin, cotter,washer,ring,follen-rod, tirfer, pull lift,rachet,empty electric-panel,switch board,eq. stay,shock absorver & damper without cutting,silent block, m.s. chain, struchure, pipe fittings, bond strip, u-types bracket,clamp,bmbc cover,trd bracket,foot-step, foot rest-plate, cut pcs strip of plate,sheet plane & twisted bar, beater,rake blast, moudel, crusible & its parts wheel barrow,doors,pandrol clip, liner,pan,protective tube, lower-spring seat, pipe &tie bar fencing, m.s. grill,anchor link,empety fire extinguisher, dummy/box,dismental & damage part of almirah, table, chair,cooler body, other various items fit for melting released from loco, carriage, sig., electric,trd, etc sort & sizes with steel. c.i & neg. n.f attechment if any. note:- 1. loading by purchaser. 2. cutting allowed for loading purpose at the time of loading. 3.delivery not allowed against part payment. 4 .if items other than melting & light melting found during cutting & loading time will be seperated & not delivered to the purchaser. location-lying near polisher shop in plot -g.
Tender For auction sale of depot ferrous scrap - scrap ferrous melting consisting of coach cutting parts, doors,window &seat bearthnframe, eq.stay,foot step, foot rest plte, m.s. & g.i pipes & sheets, pipe fittings, fabricated structure,wire & wire rope,plane & twisted bar, shock-absorver & damper without cutting, shuckle stone, side frame key, brake shoe head,brake-beam, gear case, lower spring seat, bmbc cover,follen rod,bond strip, protective tube,tirfor,rachit, pull lift, m.s. chain, nut,bolt,washer, cutter, locking plate, expended metal, slack- adjuster, u-type bracket, clamp, trd bracket,empety electric pannel box switch board, nos-plate, wheel barrow, pandrol clip, battry box,rake blast, crusible & its parts, broken helical spring up to single coil & helical spring up to three coil, pipe &tie bar fancing, signal ladder,signal box, signal pols& other various items fit for melting released from carriage, sig, electric,trd, loco, tmc,p.way of sorts & sizes with steel,c.i., & neg. n.f. attechment if any. note :-1. loading by purchaser. 2. delivery not allowed against part payment. 3. cutting allowed for loading purpose during at the time of loading. 4. if items found other than melting at the time of cutting & loading will be seperated & not delivered to purchaser. 5. material should be delivered in sequence as per location mentioned above. location-lying at 02 (two) places at travereser- 1) line no.-11 near boundary wall. 2) near tree no. g-03 in plot- g.
Tender For annual shutdown works for the year 2026 (group - 2) of dust collectors of steel melting shop, moulding room and wheel final processing shop and other works.
Tender For supply of mechanical engineering lab materials - mechanical engineering lab materials, serve motor drive kitinterface l293d motor driver ic with arduino to control direction of rotation of two dc motors), bldc motor kitbldc motor 1 nobldc motor drive -1noinbuilt volt and ammeter and rpm meterinbuilt power supplyinput 230v ac, lvdt trainer kit complete educational trainer for linear variable differential transformer (lvdt) displacement measurement. built-in ac excitation source and signal conditioning circuitry for lvdt operation. micrometer assembly for precise linear movement of the lvdt core. displacement range ~10 mm with clear front-panel adjustments for zero & calibration. digital display (typically 3 -digit) for direct readout of conditioned output/displacement values. test points and banana sockets for signal observation on external instruments. self-contained unit in a durable enclosure with labeled controls and educational layout. includes user manual and patch cords for experiments. operates on 230 v ac, 50 hz mains supply., multi-cylinder petrolphase : single phase load: mechanical load with ropenumber of cylinders : 4displacement : rope brakepower : 65hp,4000 rpm,1396 ccbrand material : mild steelengine type : 4 stroke self startfrequency : 15hzfuel consumption : petrolfuel tank capacity : 5 letermorh s test rig, tail stock assemblyheavy-duty lathe tailstock assembly for training; cast iron body with base, barrel (quill) ~50 75 mm stroke, hand wheel feed, dead centre mt2/mt3, set over screws for taper turning, spindle clamp, complete with all internal parts for dismantling and reassembly; suitable for 300 400 mm centre height training lathe., dc motorvoltage 220-440 v dcpower - 180 w speed - 200 rpm, hydraulic cylinderdouble acting hydraulic cylinder, bore 40 50 mm, stroke 200 300 mm, working pressure up to 100 160 bar, steel tube with honed bore, hard chromed piston rod, front & rear end caps, piston with seals and wear rings. supplied as standalone unit with suitable mounting for dismantling, inspection and reassembly., hydraulic opreated directional control valve (dcv)manually operated 3/2 or 4/2 way spool type hydraulic directional control valve, nominal size ng06 (cetop 3) or equivalent, rated pressure 210 bar, flow 20 40 lpm; valve body with hardened and ground spool, centering springs, ports p a b t clearly marked. supplied on small mounting plate for dismantling, inspection and assembly practice., bearing with shaft assemblyteaching unit with shaft 25 35 mm dia mounted in housing with deep groove ball bearings (6205 / 6206 class) at both ends; includes locking arrangements (circlips, lock nuts, covers). designed for repeated removal, cleaning, lubrication and refitting of bearings, with provision to mount on bench or test rig., coupling unit using driving and driven shaft plumber block bearing unit1. the plummer block housingmaterial: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing).sealing: felt seals or v-ring seals (to demonstrate lubrication retention).lubrication: provided with a grease nipple at the top center for manual lubrication practice.2. the bearingtype: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series).bore diameter: standard 25mm or 30 mm (ideal for lab scale).mounting: adapter sleeve mounting (h-series) to teach students how to lock a bearing onto a smooth shaft.3. shafting and couplingshaft material: ground carbon steel (en8 or en9) for high surface finish.coupling type: * flexible coupling: to demonstrate the bearings ability to handle slight misalignment.rigid flange coupling: to demonstrate traditional direct connection.driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven)., spring test machine load & displacement sensing load cel * capacity: 0 10 kno accuracy: 1% fs (better if 0.5% fs) displacement sensor * lvdt / digital encodero accur
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent