Web Analytics Made Easy - StatCounter

Alpha Beta Counting System Tenders

Get complete information related to latest Alpha Beta Counting System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Alpha Beta Counting System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Alpha Beta Counting System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40793241 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For corrigendum : tender for supply of spares for tsi systems installed in mtps unit1 dvc - piezoelectric velocity transducer , model 793v100-5 , make meggitt. , extension cable , pnr - mc-at-010-00 for (piezoelectric velocity transducer model - 793v100-5) , make meggitt. , 8mm tip dia reverse mount version proximity probe with 1 mtr integral cable for relative shaft vibration , model tq912 , make meggitt. , extension cable of 9 mtr length for proximity probe , model ea902 , make meggitt. , proximity probe for relative shaft vibration , model tq902 , pnr 111-902-000-011- a1-b1-c150-d2- e1000-f0-g0-h10 , make meggitt. , proximity probe for axial shift , model tq902 , pnr 111-902-000-011- a1-b1-c40-d2- e1000-f0-g0-h10 , make meggitt. , 18mm tip dia standard version proximity probe with 1 mtr integral cable for ip lp rotor expansion , model tq403 , make meggitt. , extension cable of 9 mtr length for ip lp rotor expansion , model ea403 , make meggitt.

CTN :40556113 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For corrigendum : supply of switch proximity detector single channel dualoutput with phase reversal and line fault detection specification as per annexure b1 , switch proximity detector two channel single output for each channel specification as per annexure b2 , smart transmitter repeater 420ma hart specification as per annexure b3 , signal splitter nonintrinsically safe applications specification as per annexure b4 , ai barriers with dual op with hart compatibility at both ends specification as per annexure b5 , ai barriers for plc smart transmitter power supply output current sink specification as per annexure b6 , smart transmitter power supply dual output 4 ma 20 ma output current sink specification as per annexure b7 , current voltage driver specification as per annexure b8 , voltage repeater vibration transducer interface specification as per annexure b9 , resistance isolator specification as per annexure b10 , hart multiplexers specification as per annexure b11 , pulse isolator specification as per annexure b12 , frequency converter with trip values acdc supply voltage specification as per annexure b13 , general purpose trip amplifier input 420 ma15 vdc output two relay op and one 420 ma op specification as per annexure b14 , switch operated relay 2 channel is output specification as per annexure b15 , general purpose trip amplifier input 420 ma15 vdc output two relay op specification as per annexure b16 , do barriers for plc specification as per annexure b17 , repeater power supply 420ma hart 2 or 3 wire transmitters smart transmitter intrinsic safety applications specification as per annexure b18 bid number/ & ( * ) : gem/2025/b/6290918 dated/ + : 31-05-2025 bid document/ 3 3 1 / 17

Central Government/Public Sector

CTN :40905469 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of digital vibration meter, measures rms velocity in the range of 0.1 to 199.9 m/sec t-rms and peak, vibration transducer- piezo electric type accelerometer, sensitivity of transducer : 10 pc/m/s2 simila r to metravi vib-30 plus [ warranty period: 30 months after the date of delivery ]

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

State Government

CTN :40851487 Due date: 28 Jul, 202528 Jul, 2025 14.47 Lacs
Tender For purchase of piezo velocity vibration transducer for vms system of tac and raw water pump installed in ph-4 of stps sarni.
 Loading, Please wait...

Connect us via What's Up