Get complete information related to latest Alternator Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Alternator Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Alternator Sale Tenders.
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For special repair for replacement of 500 kva diesel generator set at power house against ber item engine sm no 767 6007 dg 15 alternator sm no 767 6007 al 15 for brichgunj mil stn sri vijaya puram
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - during starting of port diesel alternator (make: m/s caterpillar, c 4.4 dita, 86 kw) smoke and sparks were observed from alternator winding. during di/dr, alternator winding was observed burn out. defect to be rectified and proved for satisfactory operation. in way jobs includes removal and fitment.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs rajtarang; e 188 6000 hrly routine on port diesel alternator to be carried out through approved competent firm m/s island prime power pvt ltd sri vijaya puram as pe..
Tender For overhauling of hydraulic cooling system of engines, lifting platform, traction alternator, control wiring, and diesel generator set in tower cars scheduled for poh during 2026-27 at carriage repair workshop, hubballi
Tender For providing of repair and overhauling service - multifunction machines mfm; defect rectification on port diesel alternator; no; buyer premises
Tender For providing of repair and overhauling service - condition assessment trials and safety checks needs to be carried out by pac firm gainwell for accord of first 5 percent running hours extension of main engine and diesel alternator; condition assessment trials and s..
Tender For providing of repair and overhauling service - 4536 complete offloading short refit of fc urvash; fc urvashi; yes; buyer premises - diesel alternator main engine gear box steering box