Get complete information related to latest Aluminium Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminium Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminium Cable Tenders.
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For supply of pvc insulated multi stranded aluminiumcable single core of size 35sq.mm.(7/2.5 mm) conforming to rdso specification no.rdso/pe/spec/tl/0027-2002 (rev '0')june-2002 with amendment no.1. however, the firms may quote for latest specification/drawing with amendment if any issued by rdso/icf/rcf. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , plasticized pvc tapes with non- thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , heater elements (q3) , miniature circuit breaker boards for voltages conforming to is 13032 (q3) , non modular piano type domestic electrical sockets isi marked to is 1293 (q2) , non modular piano type domestic electrical switches isi marked to is 3854 (q2) , capacitors for electric fan motors as per is 1709 (v2) (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , elecric bells and accessories as per is 2268 (q3) , ceiling rose , isolator , isolator tp , isolator tpn , modular fan regulator , modular socket , modular switch , angle holder , angle holder , holder angular , change over switch , fan regulator , gang box 2 way , gang box 4 way , gang box 6 way , inverter 9w led bulb , led mirror light , mcb 100 a , mcb 16 a , mcb 32 a , mcb 20 a , mcb 25 a , mcb 40 a , mcb 6 a , mcb 63 a , mcb 10 a , mcb 63a , aluminiumcable 6 sqmm , aluminiumcable 6 sqmm , pvc copper cable , copper wire frls , switch socket combination , switch socket comb 16 amp , switch socket comb 6 amp , cable flexible , thermostate , xlpe armd cable * /bid number : gem/2026/b/7716821 + /dated: 30-06-2026 ' ' / bid document 1 / 69
Tender For supply of fuel filter for genr set 2 point 1 kva , oil filter for genr set 2 point 1 kva , air filter for genr set 2 point 1 kva , spark plug for genr set 2 point 1 kva , condenser for genr set 2 point 1 kva , gasket for genr set 2 point 1 kva , fuel filter element for genr set 2 point 1 kva , fuel filter for genr set 15 kva , oil filter for genr set 15 kva , coolant for genr set 15 kva , air filter for genr set 15 kva , fan belt for genr set 15 kva , change over switch 63 amp , power cable 10 sq mm , pvc aluminiumconductor cable of size 10 sqmm twin core , oil filter for genr set 5 point 5 kva , fuel filter for genr set 5 point 5 kva , air cleaner for genr set 5 point 5 kva , main switch spn 16 amp , ac plug 15 amp mf , electric insulation tape , brass bty terminal connector , main switch 15 amp , spark plug for genr set 5 point5 kva , bty 12v 11 point 2 ah 10 hr , fan belt for genr set 15 kva , high pressure pipe for genr set 15 kva , dynamo belt for genr set 15 kva , fuel filter for genr set 15 kva , oil filter for genr set 15 kva , solenoid switch of self starter , fuel filter for genr set 30 kva , oil filter for genr set 30 kva , fan belt for genr set 30 kva , dynamo belt for genr set 30 kva , air cleaner for genr set 30 kva , kero heater wicks , fuel refilling pump , fuel filter for genr set 32 point 5 kva , oil filter for genr set 32 point 5 kva , fan belt for genr set 32 point 5 kva , dynamo belt for genr set 32 point 5 kva , air cleaner for genr set 32 point 5 kva , exhauset fan , led bulb , flexible wire 12 core , 5 amp switch socket comb , pvc bib cock , pvc stop cock , water taps pvc , red paint , black paint , olive green paint , white paint , terracotta paint , silver paint , terracota paint , brown paint , tarracotta paint * /bid number : gem/2026/b/7723515 + /dated: 29-06-2026 ' ' / bid document 1 / 47
Tender For supply of pvc insulated single core multi stranded unsheathed aluminiumcable size: 4 sq. mm (7/0.85 mm), voltage grade 1100v conforming to rdso specn.no.rdso/pe/spec/tl/0027 - 2002 (rev.-0) with amend. no 1 with insulation colour in equal quantity red, yellow& blue. [ warranty period: 30 months after the date of delivery ] ]