Get complete information related to latest Aluminium Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminium Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminium Coil Tenders.
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digital insulation tester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For tender for supply of danfoss make compressor and other spares -hermetically sealed scroll compressor , model no. sm110s4vc , 3 phase , 50hz , make danfoss. , reciprocating compressor rotolock type , model no. mtz80hp4ave , 3 phase 340-440v , make danfoss. , reciprocating compressor , rotolock type , model no. mtz56hl4bve , 3 phase , 400v , 50hz , make danfoss. , compressor reciprocating , model nomtz64hm4bve , make danfoss maneurop , hermetically sealed reciprocating compressor model no. mtz72-4vm , 3-phase , 50 hz , make danfoss , hermetic filter drier , model no.023z5007 , type dcl 162 , makedanfoss. , hermetic filter drier , model no.023z5013 , type dcl 032s , make danfoss. , hermetic filter drier , model no.023z5029 , typedcl 163s , make danfoss. , hermetic filter drier , model no. 023z5063 , type dml 162s , make danfoss. , hermetic filter drier , model no.023z5067 , type dml 164s , make danfoss. , hermetic filter drier , model no. 023z5044 , type dml 164 , make danfoss. , hermetic filter drier , model no. 023z4581 , type dml 165s , make danfoss. , hermetic filter drier , model no .023u4381 , make danfoss. , thermostatic expansion valve , typetd 1 , model no.068n2937 , makedanfoss , filter drier model no023z5005 , make danfoss. , thermostatic expansion valve type te2 , model no.068z3403 , make danfoss , thermostatic expansion valve type te2 , model no.068z3209 make danfoss , thermostatic expansion valve type te2 , model no.068z3348 , make danfoss , thermostatic expansion valve type tz2 , model no.068z3496 , make danfoss , pressure switch , 060-124391 type kp15 , contact function spdt , pressure connection size 1/4 , pressure connection type flare , pressure male. , pressure switch model kp5 8 to 32 bar , spdt , flare type make danfoss , orifice for t2 /te2 type therm ostatic expansion valve , model no. 068-2015 , make danfoss , orifice for t2 /te2 type ther mostatic expansion valve , mode l no. 068-2006 , make danfoss , orifice for t2 /te2 type therm ostatic expansion valve , model no. 068-2007 , make danfoss , orifice for t2 /te2 tyep therm ostatic expansion valve , model no. 068-2008 , make danfoss , orifice for t2 /te2 type therm ostatic expansion valve , model no. 068-2009 , make danfoss , solenoid coil model no. 042n7 651 , electrical connection 230 v ac , make danfoss. , digital temperature controller model no. 080g3266 , erc213g , temp. sensor , supply voltage 230vac , make danfoss. , rotolock valve set , model no. 7703006 v07 (1-3/4in-7/8in) , v04 (1-1/4in-3/4in) make danfoss. , rotolock valve set , model no. 7703005 , v09 (1-1/4in-5/8in) , v 06 (1in-1/2in) , make danfoss. , rotolock valve set , model no. 7703004 , v06 (1in-1/2in) , v01 ( 1in-3/8in) , make danfoss. , rotolock valve set , model no. 7703009 , v02 (1-3/4in -1-1/8in) , v04 (1-1/4in-3/4in) , make danf oss. , filter drier for a.c.plant make danfoss model dcl dml-165 , cooling thermostat make danfoss model kp-69 range -5 to 35 degree centi. diff lt 4.5 to 25 degr cent ht 1.8 to 07 degr
Tender For supply of electromagnetic disk brake coil for eot crane range up to 14kgm torque operating condition coil supply voltage 440vac ac distributed designed (+/-10%) &frequency 50hz (plus or minus5 percent)voltage 440vac 3phase brake coil for disk bake 150em disk brake &150xem disk brake 190em diskbrake &190xem disk brake 235em disk brake &235xem disk brake. note: sample to be got approved before bulk supply ]
Tender For 2000w resistive heating element for electric stove,circular shape multi ring formed out of tubular single element,with outer supporting ring,moisture proof seals on tube ends,outer dia of coil:200mm+-5mm including outer supporting ring,isi certified brand and suitable for working on 230v ac,50hzsupply. ]
Tender For corrigendum : procurement of “building spares and outdoor supply source. - geyser assembly 6-hole, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, geyser coil 2kw, geyser coil, 2 kw, 230 vac, 25 ltrs capacity, thermostat for geyser type-9-inch length, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, electric geyser neon indicator light red, 240v ac red indicator light pilot lamp, neon bulb, electric geyser neon indicator light green, 240v ac green indicator light pilot lamp, neon bulb, gyser model: ap-25v, cap:25ltrs, racold,crompton arno neo 25-l 5 star rated storage water heater (geyser) with advanced 3 level safetybrand cromptoncapacity 25 litres power source corded electricproduct dimensions 337.5w x 54.2h cmspecial feature auto restart, fast heating, geyser safety valve, for, 25 litre capacity geysers, make: crompton., cut out relay for geyser- type 9-inch, supply voltage-250v ac required for, 25 litre capacity geysers, make: crompton, ceiling fan, with copper winding coilnumber of blades-3, power consumption-52w, motor speed-380 rpm, design type-economy, type-ceiling fan, bee star rating-1, body material-aluminium, colour-white, 2 years company warranty, make-havells, crompton, bajaj, usha., portable type extension cable reel, without cable, portable i.e. lift & carryextension cable reel, heavy gaugetubular frame, sheet steel roller and al. discs with 2nos. m/c outletsocket 20a 3pin. reel capable of loading 50mtrs. 3core x 2.5mm.sq.pvc/pvc round sheathed flexible cable. (without cable)., power extension board - rating -15 amp, single phase extension board with 4core 2.5 sq.mm pvc insulated flexible cable (30 meter)component to be included in the board as bellow:1. 25a 2-pole mcb and 25a 2-pole rccb at incoming.3. 01 no s 1 phase 15a industrial socket with plug top and individual switch circuit4. 03 no s 1 phase 15a socket with individual switch circuit, industrial type extension box, fabricated from 16swg crcasheet of size 350mm x 250mm x 250mm. tower type powdercoated in deep orange shade gasketed doors conforming toip 55 and with the following components duly wired: -incomer: mcb and indication lampoutgoing: 4 no s f 10a socket & plug top each individuallycontrolled by a 10a dp rotary switch.
Tender For procurement of different spares for chinese make elevators under emiph-i, sgtpp. - procurement of different spares for chinese make elevators under emiph-i, sgtpp., limit switch,car door contact,type:ds131 for seec express elevator 1no, ue-230vac/110vdc, ie-2a/0.5a, ui/ith-500v/10a, ip20, transparent enclosure ( please follow additional data: model: s3-1370b: normal close make: beto or model: ndox 41k ), shoe liner car guide shoe liners # shoe liner(car guide shoe liners) 1set/4pcs e.c.e ( please follow additional data: guide shoe; moc: nylon; dimension: 150mm x 30mm x 30mm (as per sample) ), landing door shoe for ece make elevator acme make: fermatorrn ( please follow additional data: door chanel shoe, dimension: 56mm x 40mm; thickness: 2mm with both side rubber. (as per sample) ), v belt, a 1180 ( please follow additional data: belt, qxpz 1180 cogged raw edge epdm wedge belt, fenner ), belt, timing, 3600-s8m-15, htd for seec express elevator car door type- high torque drive (htd) timing belt, length-3600mm, width-15mm, belt thickness- 5.6mm, tooth height-3.4mm, tooth pitch-8mm, material-neoprene rubber withfiber glass core., reed switch ( please follow additional data: for elevator (as per sample), sichuan express elevator co. ltd. ), vfd for car door astar s2 20p4a2 power 0.4 kw,i/p 220vac,50/60 hz,5.3 a,o/p 220vac,0-50 hz,3a.0.6 kva, oil pot(at feeder on car top) ( as per sample ), hooter industrial 230v ( with power back-up for sichuan express elevator co. ltd. ), rotary blower fan for elevator # ( car roof fan, crossflow fan, model: zqf-330 200, 230v ac, 25w, 1270/1350 rpm, 340/360 m3/hr ; make: ningbo grand fans co. ltd. ), switch,red,1no,call push button dia-37mm for seec express elevator 24vdc, illuminated, colour- red, flush mount ( landing: up/down-25 nos., car: open-close-15 (each); 1-5: 10 (each); 6-9: 5(each) ), board, lop,intl 2000-dv/v1 for seec express elevator sichuan express elevator co. ltd., door sensor (lambada),model:ms720 ( make- t l jones or equivalent ), rope oil for elevator rope usha wrl-60 usha martin, brake coil for hoist,230v ac ( please follow additional data: brake coil for sichuan express elevator co. ltd., coil voltage: 110v dc (as per sample) ), dynamic braking unit,cdbr-4030b,400 v yaskawa vvvf drive cimr f7a4030,30 kwfor s/r vvvf drive, expansion pcb for elevator intl 2000-ex sichuan express elevator co. ltd.