Tender For supply of 3 core 185 sq. mm. xlpe insulated and pvc sheathed stranded, screened steel strip armoured aluminiumconductorcable 11 kv grade, as per is: 7098 (part-2), make: havells/polycab/universal cables/rr kabel or similar. [ warranty period: 36 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of 3 core 185 sq. mm. xlpe insulated and pvc sheathed stranded, screened steel strip armoured aluminiumconductorcable 11 kv grade, as per is: 7098 (part-2), make: havells/polycab/universal cables/rr kabel or similar. [ warranty period: 36 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductorcable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductorcable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductorcable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For corrigendum : repair to security/ compound/ boundary walls, concertina coils, barbed wire and fencing/ iron works in tech area at af stn phalodi
Tender For repair / maintenance and painting of boundary wall, security wall, fencing, barbed wire, concertina coil and other miscellaneous b/r items at af station bareilly under ge (af) bareilly
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh
Tender For supply of modular piano type domestic electrical switches isi marked to is 3854 (q2) , modular piano type domestic electrical sockets isi marked to is 1293 (q2) , light emitting diode driver (q4) , led garden light (v2) (q2) , ceiling rose - is 371 (q3) , tower bolts (ferrous metals) as per is 204 (q3) , switch socket combination box 5 amp , lamp holder batten type , three pin plug top 16 amp , plug top 5 amp , led bulb 9 watt , led bulb 12 watt , led bulb 15 watt , buliding security light 25 watt , led tube light fitting 20 watt , service cablealuminium 4 sqmm 2 core , service cablealuminium 10 sqmm 2 core , led flood light 400watt , led batten battery type 20 watt , plywood commerical 7x3x12mm , door seal , pvc float valve 15mm dia with rod and ball , pvc float valve 20mm dia with rod and ball , wpc board with both side laminated wooden finished and other side balancing 18mm thick , stainless steel wire mesh cloth , pvc cabinet mirror 555x350x120mm * /bid number : gem/2026/b/7647405 + /dated: 29-06-2026 ' ' / bid document 1 / 33
Tender For general-maintenance work in court complex for ensuring security of court building at district court, kalpetta-providing barbed wire fencing at top of compound walls and grill work for property rooms and main entrance at court complex kalpetta