Get complete information related to latest Aluminum Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminum Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminum Conductor Tenders.
Tender For tender for work of dismantling of existing conductor and stringing of acsr dog conductor on 66kv d/c utran-kosamba line loc. 42 to 50a under kim am division under circle office bharuch.
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminumconductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For regarding supply of lt 1.1 kv 3.5 core aluminumconductor 120mm2 xlpe insulated armoured cable for connection from panel to motors along with providing suitable size of thimbles at flood site rd 36000 loharu canal.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : replacement of existing 1st circuit coyote acsr conductor by htls (equivalent to drake acsr) and stringing of 2nd circuit with htls conductor on exisitng dc towers of 66kv anekal-attibele line from 66/11kv anekal sub-station to 66/11kv attibele sub-station for a distance of 6.545kms.
Tender For corrigendum : providing additional 1x8mva 66/11kv power transformer & construction of one no. of 66kv line terminal bay for terminating second circuit line at 66/11kv allimaranahalli sub-station in kanakapura taluk ramanagara dist., and making lilo arrangement to the existing 66/11v allimaranahalli sub-station by stringing 2nd circuit line from tap point of 66/11kv allimaranahalli sub-station on 66kv ramanagara-kanakapura sc line to 66/11kv allimaranahalli sub-station on the existing dc towers using coyote acsr conductor for a distance of 0.831kms. including supply of all materials/ equipment (excluding 8mva power transformer & 11kv switchgear) and erection (including civil works) of all materials/ equipments, testing and commissioning on partial turnkey basis
Tender For estimate proposal for erection of 5km new 11kv feeder to vennacherla village from 33/1ikv nakkalapally ss which involves stringing of 5km of 11kv scoh line with 55sq mm aaa conductor along with crection of 1no. feeder vcb at 33/11kv nakkalapally ss in peddakothapally section in kollapur sub-division of nagarkurnool division of nagarkurnool circle under t&d improvements to original works
Tender For estimate proposal for erection of 5km new 11kv feeder to vennacherla village from 33/11kv nakkalapally ss w uch involves stringing of 5km of tikv scoh line with 55sq.mm aaa conductor along with erection of 1no feeder vcb at 33/11kv nakkalapally ss in peddakothapally section in kollapur sub-division of nagarkurnool division of nagarkurnool circle under t&d improvements to original works,
Tender For replacement of existing aaac dog conductor with htls conductor non metallic core having cfcc carbon fibre composite core technology equivalent to dog conductor in 132kv tadepalli-guntur sc line from loc no 1 to 106 including supply of conductor and its connected line hardware, erection, stringing, testing and commissioning of 132kv sc line along with bay modification works on both ends in guntur district
Tender For supply of 11 kv (e) grade, 3 core, 185sqmm, stranded compact circular aluminumconductor, conductor screened with extruded semi conducting compound, xlpe insulated, insulation screened with extruded semiconducting compound followed by copper tape screen. cores shall be laid up together with pvc fillers, extruded pvc inner sheathe, galvanized steel strip armored and overall pvc sheathed cable, conforming to is: 7098 part ii/1985 or latest amendment with isi mark. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]