Tender For replacement of existing acsr lynx panther conductor with acss rw lynx conductor on 132kv parawada koruprolu dc sc 44km line on turnkey basis in onm circle visakhapatnam
Tender For s/e of pcc poles, acsr conductor 200 kva t/f and 11 mtr. long solar high mast in front of sco 325 to 352 in s/c sector-29 gmm and other works contingent thereto (including 6 year dlp for t/f 5 year dlp for solar high mast and 3 year dlp for other...
Tender For providing elect. in s/c sector-45 hsvp gurugram. s/e of pcc poles, acsr conductor and 200 kva t/f in s/c sector-45 gurugram and all other works contingent thereto (including 6 yeras dlp for t/f and 3 year dlp for other items free of cost)
Tender For tender for work of dismantling of existing conductor and stringing of acsr dog conductor on 66kv d/c utran-kosamba line loc. 42 to 50a under kim am division under circle office bharuch.
Tender For corrigendum : work of erection of balance work of 66kv s/c line on h frame from 66kv sadla s/s to 66kv umarda s/s with acsr panther conductor under kisan suryoday yojana.
Tender For replacement of old acsr panther conductor with new acsr panther conductor and associated jumpher s and all other associated work of 132 kv boner aligarh v line under etd i aligarh
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : special repair /replacement of over head acsr conductor with ug cable lt panels and connected items of stn hq , hq cwe dinjan and hq cce area under ge dinjan
Tender For combined package for the following works, (1)providing intermediate tower between t.nos 06-09 in existing 66kv jalamangala- melehalli sc line on dc towers due to waterlogged at tower no.08 near thimmasandra village, ramanagara town using 66kv narrow based tower with coyote acsr conductor in operations division, kanakapura on total turnkey basis, (2)providing intermediate tower to increase the vertical clearance for existing 66kv kanakapura-chikenahalli-channapatna sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 43-44 near hunasemarradoddi village using 220kv narrow based tower with coyote acsr conductor (modified design of 220kv dc tower of vtp) in operations division, kanakapura (tower will be supplied by kptcl) on partial turnkey basis, (3) providing intermediate tower to increase the vertical clearance of existing 66kv kothipura-ramanagara sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 09-10 at ramanagara town using 66kv kptcl designed narrow based tower with coyote acsr conductor in operations division, kanakapura on total turnkey basis, (4)providing intermediate tower to increase the vertical clearance of existing 66kv maralwadi lilo line between t.nos 08-09 near hucchegowdanadoddi using 66kv kptcl designed narrow based tower with coyote acsr conductor in operations division, kanakapura on total turnkey basis.
Tender For corrigendum : supply, erection, testing and commissioning of(i) 2nos 132kv bays (conversion from 2-ph to 3-ph) at 132kv ss bellampally (ii) 2nos 132kv metering bays (conversion from 2-ph to 3-ph) at new proposed 132/25kv rtss bellampally (iii) conversion of 132kv dc line from 2-ph to 3-ph (3km) from 132kv ss bellampally to 132/25 kv rtss bellampally (iv) modification of 2 nos 132kv bays at 220/132kv mandamarri ss (v) modification of 2 nos 132kv bays at 132kv bellampally ss (vi) strengthening of 132kv mandamarry-bellampally dc line (10km) by replacement of existing acsr panther conductor with htls conductor in mancherial district on turnkey basis