Web Analytics Made Easy - StatCounter

Aluminum Conductor Sale Tenders

Get complete information related to latest Aluminum Conductor Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminum Conductor Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminum Conductor Sale Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41487249 Due date: 09 Sep, 202509 Sep, 2025 NA
Tender For tender for supply of 1.5 mm x 3 core pvc multi core copper cable with (isi mark) highest quality electrolytic grade copper and flame retardant pvc used, pvc insulated cable/wire, conductor material anti rodent, anti termite, superior, isi certified product with pvc as its insulation material and superior quality copper as its conducting material. make/brand -polycab or finolex or havells or rr kable or anchor only, leak proof pen light cells 1.5 volt heavy duty, size aa, r-6, isi marked electronic static energy meter, digital display, single phase two wire, 50hz, current rating -30 amp(minimum), as per is-13779/99 having meter accuracy-1.0,along with battery backup and abc code for the meters. technical parameters make- maxwell, hpl, l&t, 2.5 mfd 400v capacitor metal container with cylindrical shape, for ceiling fan operated at 230 v 50c/s. other spec., terms and conditions & is as per gem product id:5116877-54148403360 accepted make:- bajaj cropmton, orient, surya, havells, epcos. material shall be supplied with oem-test report, power contactors, ac rating (ampere)32, coil voltage 240 vac, contact voltage 415 vac, number of poles 3, single phase, warranty 12 month. make? bch electric,l&t, abb, schneider, legrand, havells material shall be supplied with oem-test report, 1.5 ton inverter split air conditioner rotary compressor dc type refrigerant gas-r 32/830 g, excessive operating pressure discharge-4.3 mpo, operatitng pressure of r 32 is about 12-26 bar (174-377 psi), suction- 1.7 mpo, power source 230 v +/- 10%, 50 hz ac supply, working voltage range-150-280 volt, capacity->-15amp, compressor make-whirlpool/lg/panasonic., electrode oven with minimum 15 kg electrodes holding capacity with digital temperature indicator and temperature setting manually, with operating temperature up to 300 degree celcius (approximately), with thermal cut off to prevent overheating of electrode above set temperature with chamber size to accommodate electrode of length 450mm., ed torch light with replaceable cell battery run time minimum 8 hrs as per attached specification., 1.5 sqmm size copper cable, multi stand single core(e beam) electron beam irradiated thin walled ?exible elastomeric cable with copper conductors for working voltage above 750v upto 1.8 kv/3.0kv conforming to rdso.specn. no. elrs/spec/elc/0019, rev-4 of february 2018 or any latest. firm should submit test report & certificate of authorization from oem., portable electric air blower (heavy duty) with dust extraction as per specification: voltage 110-230v, ac/dc rated input power: 800w-900w, volumetric flow rate 4.5 m3/min., no load speed: 16000 rpm. make: model bosch gbl 800e or similar.

CTN :41487923 Due date: 29 Aug, 202529 Aug, 2025 NA
Tender For tender for supply of dismantling of unserviceable air circuit breaker from lt panel by disconnecting all incoming and outgoing electrical connection and supply and fixing of air circuit breaker 4 pole 415 volts ac supply 800 amps 50 ka thermal magnetic release fixed type connecting all incoming and outgoing connection complete all as specified and directed make l and t cat part no uw108nff01800 legrand schneider 01 each , dismantling of unserviceable mccb by disconnecting all incoming and outgoing electrical connection and supply and fixing of mccb 4 pole 415 volts ac supply 320 amps 50 ka breaking capacity 50 hz with thermal magnetic release with spreader link on both side connecting all incoming and outgoing connection complete all as specified and directed make l and t cat part no du400n cm98404ooqo legrand schneider 01 each , supply laying and testing cable xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 240 sq mm 3 point 5 core complete all as specified and directed make gloster polycab wires pvt ltd grandlay plaza 80 rm , excavation in trenches not exceding 1 point 5 m wide and not exceding 1 point 5 m in depth and getting out soft loose soil complete all as specified and as directed for laying of under ground cable foundation of pole and stay etc complete all as specified and as directed 16 point 74 cum , returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick in soft loose soil complete all as specified and directed 9 point 66 cum , removing excavated material not exceding 50 m and depositing where directed at a level not exceding 1 point 5 m above the starting point all as directed 7 point 08 cum , material and labour for providing sand cushioning with dry fine sand including filling spreading levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed 5 point 02 cum , supplying and laying burnt clay bricks sub class b old size laid in trenches over cable protection complete all as specified and directed 0 point 15 per 1000 nos , laying only serviceable bricks obtained from the items specified here in before that is during taking out of under ground cable laid flat dry in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed 350 each , m and l for boring of holes horizontally under road pavement hard standing footpath blast wall without damaging the surface of road minimum 1 point 0 meter below the road surface with the help of gi tubing not exceding100mm bore for passing of underground cable complete all as specified and directed note gi pipe laid will be measured and paid separately under the respective items of schedule 10 rm , m and l for 80mm bore gi tubing light grade with all fittings laid across road or across pcc drains along electric pole or floor wall for cable protection complete all as specified and directed 10 rm
 Loading, Please wait...

Connect us via What's Up