Get complete information related to latest Aluminum Lugs Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminum Lugs Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminum Lugs Tenders.
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as
Tender For maintenance of electrical installation & fans i/c compound light, repair maintenance of pump sets, dg set, sub-station, lift, ac machine, fire fighting system at janaganana bhawan (census), salt lake city, kolkata during year 2026-27. (sh: providing man power services for day to day operation of internal & external ei).subwork/packages:providing man power services for day to day operation and internal & external ei.
Tender For annual repair and maintenance of electrical appliance, photocopier machine, computer, split a.c. and 5kva d.g. set and provision of electrical appliances etc. for the office of chief engineer (mech.) w.r.d. patna.
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be
Tender For annual repair and maintenance of iei and eei to g.b. pant hospital at atlanta point wsd, apwd in svp. sw supply of labour and electrical items for iei and eei maintenance in g.b. pant hospital, svp - supply of following category labour to asssit wireman/assistant wireman in iei and eei maintenanceun-skilled, supply of following electrical for iei & eei maintenance work.1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 6.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 10.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 16 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, modular one way switch 5/6 a , similar to indoasian /roma/ziva, modular one way switch 15/16 a , similar to indoasian /roma/ziva, modular socket 5/6 a ,3 pin ,similar to indoasian /roma/ziva, modular socket 6/16 a ,3 pin ,similar to indoasian /roma/ziva, modular fan regulator 2 module ,similar to indoasian /roma/ziva, pvc batten holder, call bell/ buzzer, single phase, modular surface box 3-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 6-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 8-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 12-way with cover plate and frame similar toindoasian /roma/ziva, pvc frls conduit pipe 20 mm, pvc frls conduit pipe 25 mm, pvc frls channel 32mm, pvc junction box 20mm 1-way, pvc junction box 20mm 2-way, pvc junction box 20mm 3-way, pvc junction box 20mm 4-way, pvc junction box 25mm 1-way, pvc junction box 25mm 2-way, pvc junction box 25mm 3-way, pvc junction box 25mm 4-way, pvc elbow 20 mm, pvc elbow 25 mm, pvc bend 20 mm, pvc bend 25 mm, pvc nail clamp 20 mm, pvc nail clamp 25 mm, pvc ceiling rose, 3 pin, 6 amps. to 32 amps. ratings , sp mcb, "c" curve, 10 ka breaking capacity, tp c-type mcb 32 amps., tpn c-type mcb 32 amps., tpn isolator 40 amps., tpn isolator 63 amps., tpn isolator 100 amps., tp mccb 16ka 100 amps., tp mccb 25ka 200 amps., tp mccb 50ka 400 amps., modular ac distribution box 20amps with plug top, mini modular sp mcb 20amps., 5 amps 3-pin plug top, 16amps 3-pin plug top, pvc insulated aluminium service wire twin core 6.0 sqmm, capacitor 2.5 mfd, procelain 500 a kit kat fuse unit open type, fuse wire 300amps, aluminumlugs 35 sqmm, aluminumlugs 50 sqmm, aluminumlugs 90 sqmm, aluminumlugs 120 sqmm, aluminumlugs 150 sqmm, aluminumlugs 185 sqmm, aluminumlugs 240 sqmm, aluminumlugs 300 sqmm, aluminumlugs 400 sqmm, 1-star ceiling fan of sizes 1200 sweep white in colour, exhaust fan 300 mm sweep metal body heavy duty, led street light fittings 50 w, led batten type tube light 20w, led retrofit tube light frame,20w, led tube lamp,20w, led bulb 9w, b22 3-star, led bulb 0.5 w, b22 (red and green), fr - electrical insulation tape, al. alloy/ cadmium plated iron screws, 35 mm, iron screws, 25 mm x 7 mm, iron screws, 35 mm x 7 mm, iron screws, 52 mm x 6 mm, nylon cable tie 300mm, ball bearing 6201, ball bearing 6202, wall grip, hylem sheet full 8x4 feet, wall fan 450 mm (metal body), wall fan 600 mm heavy duty (metal body)