Web Analytics Made Easy - StatCounter

Amc Airconditioning Tenders

Get complete information related to latest Amc Airconditioning Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amc Airconditioning Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amc Airconditioning Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45518539 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : supply of direct evaporative air cooler (v2) isi marked to is 3315 (q2)

State Government

CTN :45722047 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of water and electrical material at gp/kothulna/zp/ngp/tender no1/2026-27/1st call - cleansol bleaching powder, bleaching powder(calcium hypochlorite), pvc pipe 75 mm 4 kg, pvc pipe 60 mm 4 kg, pvc pipe 6 kg "3", pvc pipe 6 kg "4", pvc pipe 6 kg "2.1/2", pvc maintenance coupling 6kg "3", pvc maintenance coupling 6kg "4", pvc maintenance coupling 6kg "5", g i pipe 1", g i pipe 2", g i pipe 3", g i pipe 4", g i pipe 2.5", g i mechanical joint "4", g i mechanical joint "6", g i mechanical joint "2.1/2", sluse vleve 2", sluse vleve 2.5", sluse vleve 3", air valve 1" singal ball, air valve 2" double ball, flanch "2", flanch "2.5", gi elbo 1", gi elbo 2", gi elbo 2.5", pvc elbo 1", pvc elbo 2", pvc elbo 2.5", pvc tee 1", pvc tee 2", pvc tee 2.5", pvc tee 6kg "4", pvc tee 6kg "6", pvc bend "1", pvc bend 2", pvc bend 2.5", gi tee 1", gi tee 2", gi tee 2.5", gi bend 1", gi bend 2", gi bend 2.5", gi coupling 1", gi coupling 2", gi coupling 2.5", pvc coupling 2.5", pvc sadal 2", pvc sadal 2.5", pvc sadal 3", soluation, 3 hp 8 steg pump ( submursibl pump), 3 hp 8 steg pump ( submursibl pump), main switch 5 hp, 1/18 1 mm wire aluminium, 1/18 wire 1.5 mm aluminium, 1/18 wire copper, 2.5 mm service wire, 4mm service wire, 6mm service wire, 8mm service wire, pendent holder anchor, tape roll anchor, 5w led bubl havells / wipro / philips, 7w led bubl havells / wipro / philips, 9w led bubl havells / wipro / philips, 12w led bulb havells /wipro / philips, 15w led bulb havells / wipro / philips, 20 w led bulb havells / wipro / hilips, 23w led bulb havells / wirpo / philips, 26w led bubl havells / wipro / philips, 30w led bubl havells / wipro / philips, 15w srteet light havell / wipro / philips, 18w srteet light havell / wipro / philips, 20w srteet light havell / wipro / philips, 24 w srteet light havell / wipro / philips, 30 w srteet light havell / wipro / philips, 36 w srteet light havell / wipro / philips, 40 w srteet light havell / wipro / philips, 50 w srteet light havell / wipro / philips, claim for street light, led bulb fitting 18 to 30w, ceiling fan (all type), desert cooler (all type)

Central Government/Public Sector

CTN :45491090 Due date: 07 Jul, 202607 Jul, 2026 25.00 Lacs
Tender For corrigendum : repair/maint of summer appliances, deep freezer, water cooler and (ac) air conditioner at mffr under age (i) mffr

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45710561 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For framework agreement for fabrication of air cooler piping items such as main header pipes, nozzle assembly and inlet/outlet distribution piping/nozzles.

State Government

CTN :45710466 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For green/white board, dustless chalk, duster, dustbin, notice board, whiteboard marker, podium / lecture table, table, computer table, chair, large table, tablecloth, sofa set, cushioned chair, almirah / wardrobe, bookshelf, curtains, desktop computer + ups, printer-cum-scanner, wifi internet, portable mic system, air conditioner (ac), air cooler, refrigerator, water cooler + ro, battery + inverter (5 kva), cctv camera

CTN :45738288 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For desert air cooler

CTN :45742282 Due date: 10 Jul, 202610 Jul, 2026 1.70 Lacs
Tender For supply of direct evaporative air cooler (v2) isi marked to is 3315 (q2)

CTN :45715466 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of two burner electric stove , chapati making electric stove , jumbo cooler , air curtain , electrical wiring , installation of all equipments
 Loading, Please wait...

Connect us via What's Up