Get complete information related to latest Amf Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amf Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amf Panel Tenders.
Tender For corrigendum : supply, installation, testing and commissioning of silent type diesel generator set 01 no of 160 kva capacity along with amfpanel and allied works to be installed in girls hostel at govt. ayurvedic college and hospital, akhnoor, jammu
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For corrigendum : comprehensive maint of diesel generator set including amfpanels, maint of poles, various types of lights, lt panels, ats / changeover switch, sub stn boards and connected accessories in kamptee cantt and fort area nagpur under ge kamptee.
Tender For corrigendum : repair/maintenance of dg sets, amfpanels , control panels, voltage stabilizers, isolation transformers, air compressors ,earthing/lightning protection and connected work of different capacity in east wing and singhpur in tech area af station gwalior
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amfpanel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For corrigendum : repair repl of intl elct wks incl rewdg of clg fan exh fan w/m fan lt ftgs sub main wirg geyser and oth allied wks incl ot lts at ph i of mh kke repair maint of diesel generator set amf pnls synch pnl and allied wks at mh kke range hls area hq 41 arty div and aund - repair replacement of internal electric works including rewinding of ceiling fan, exhaust fan, wall mounted fan, light fittings, sub main wiring, geyser and other allied works including ot lights at phase-1 of mh khadki including 41 arty div and repair and maintenance of dg set, amfpanels, synchronising panel and allied works at mh khadki, range hills area, hq 41 arty div and aundh military complex under ge (mh & rh) khadki
Tender For corrigendum : supply, erection, testing and commissioning of 100 kva diesel generator set with amfpanel in various esi hospitals across the state of punjab (3rd call).
Tender For corrigendum : supply, erection, testing and commissioning of new diesel generator set of different capacity with amfpanel installed at various hospitals in the state of punjab.(2nd call)
Tender For upgradation and modification of existing sports facilities and construction of indoor multipurpose building for sports facilities at iit(ism) dhanbad. (sh:- construction of pavilion building, seating steps, seating mound, development of natural cricket ground at upper ground and construction of pavilion building- 01, 02 & 03, seating steps, seating mound, development of 08 lane running synthetic track & development of natural football ground at lower ground i/c internal water supply, sanitary installation, drainage, sewerage, internal e.i. & fans, u.g. tank, storm water drains, roads & paths, fire extinguisher, fire alarm system, ups facade lighting, signages, street lighting, horticulture & landscaping and other development work & bulk services (civil & electrical) (package-i & ii) (sh:- providing, installing, testing and commissioning of 58.5 kva, 3-phase, silent type diesel generating set with automatic mains failure (amf) panel.)