Get complete information related to latest Amf Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amf Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amf Relay Tenders.
Tender For corrigendum : supply of hipase- p numerical generator protection relay make: andritz, model - hipase p , retrofitting and itc of 2 nos. hipase-p protection relays & integration with existing scada system
Tender For corrigendum : supply of procurement of spares for til make husky 620 cranes of kusmunda ocp d d---- part no. - z7486000093 , trans oil temp. gauge 24v 50150 deg. c, part no. - z7486000094 , fuel gauge 24v 04by4, part no. - z7486000095 , pressure senderswitch-oil, part no. - z7486000103 , temp senderswitch-coolant, part no. - z7486000104 , fuel gauge 24v, 0-1by1, adj, part no. - z7486000178 , kit wiper accessorries, part no. - z7810000001 , toggle switch mom on - off - on mom, part no. - z7872000174 , toggle switch on - off - on mom, part no. - z7872000175 , toggle switch on - none - on, part no. - z7872000176 , toggle switch off - none - on mom, part no. z7872000219 , nylon tube, parker no. tpu 10x1. 5by550, part no. - z7910000198 , wheel cylinder, part no. z9049001328 , brake shoe with lining, part no. z9049001329 , pull spring, part no. - z9049001375 , compression spring, part no. - z9049001376 , switch a2b, part no. - z9352000126 , seal kit for steering cylinder, part no. - z9372005583 , seal kit o-r jack, part no. - z9372005599 , seal kit-suspension, part no. z9372005924 , solenoid, part no. - z9926000965 , solonoide coil 24v, part no. - z9926001058 , solenoid, part no. - z9926000966 , cartridge valve, part no. z9926001461 , seal kit, part no. - z9974000957 , bremstrommel-drum brake assy, part no. z9049001360 , universal joint, part no. - z9049001351 , hoist rope, part no. - x7780000021 , stop light switch, part no. - 334142 , radiator with cac, part no. v7726000045 , seal kit for 15 port hyd. swivel w7364000094, part no. - w7364000094-sk , motor wiper 24v 17w, part no. - z7632000001 , hydraulic oil pressure gauge, part no. - 8341484 , water pipe radiator to engine, part no. - w4131800122 , water pipe -engine to radiator, part no. - w4131800123 , head lamp assy, part no. - z6581000094p , repair kitbrake chamber, part no. - 8312032 , repair kit-system protection valve, part no. - 8312422 , hose kit, part no. - hoskt620 , rear view mirror, part no. - z2162400051 , disc brake pad, part no. - z9904100492db treadle valve , part no. - 7683000069, relay 24v 50 amps, part no. - 7750000058 repl 02309790, relay 24v 20 amps, part no. - 7750000710, nylon pipe 1by4 o-d, part no. - 8308517, dual brake valve, part no. - 8311788, air cylinder, part no. - 8312251, solenoid valve, part no. - 8312280, repair kit, air cyl. , part no. - 8312343, system protection valve, part no. - 8312375, wiper arm & blade pantograph, part no. - 8315281, solenoid valve, part no. - 8340241, m. c. assy. -bi-64068447 08, part no. - 8340369, sheave, part no. - 8985576, u joint, part no. - 9364101867, fan belt, part no. - f0t00800, transmission shifter-4speed, part no. - u7872000197, floating sheave, part no. - v6718000011, nylatron sheave, part no. - v6718000012, o/r jack, part no. v7372000195, gear pump - 24 c. c. , part no. v7722000110, engine stop solenoid, part no. x3992400, solenoid engine stop, part no. x7009000019, vibrosonic horn ht -24v, part no. x7025000017, reverse buzzer, part no. - x7025000019, sheave bearing, part no. - x7086000031, fuse holder in line blade type, part no. - x7482000040, oil level and temp. gauge, part no. - x7486000086, ignition switch, part no. - x7872000051, switch - head - side lamp, part no. - x7872000097, limit switch, part no. x7872000178, temperature switch, part no. x7872000189, battery disconnect switch, part no. x7872000192, cvmc assembly, part no. - z2162400025, //bid details2 / 75
Tender For corrigendum : maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numer
Tender For corrigendum : supply of various switchgear spares for emd-3,wtps. - abb make 3 pole power contactor type : ax50-30-11, coil voltage 110 v,50 hz ac, abb make 3 pole power contactor type : ax80-30-11, coil voltage 110 v,50 hz ac, abb make auxiliary contactor 110 v ac, 2no + 2nc contact,type n22e, front mounted add on block(suitable for contactor type: ca5x-22e; 2 no + 2 nc, abb make, abb make tmax 3 pole motor protection circuit breakers type : t2s 160, in : 52a, icu : 50ka, auxiliary contact for mpcb hkf1-11 with 1no+1nc contact, over load relay, abb make ,type ta25du14m,range 10-14 a, abb make thermal overload relay type : ta75du 42, amp range : 29a to 42a, abb make thermal overload relay type : ta75du 52, amp range : 36a to 52a, siemens make mccb 3-pole 125a breaking capacity 55ka at 415v, 50hz reference no:-3va1112-5ee32-0aa0, vaccume contactor 300 amp. rating 415 volt with 2 no + 2 nc coil voltage 110v ac., aux.contact block - 1no + 1 nc for vacuum contactor type 3rt - 12, control & switchgear make digitalmotor protection relay.type-csmpm-06 si, 1.5kw l&t mf 1-1 phase dol starter category ss97227, l&t make dol starter,in sheet-steel enclosure,type-mk1,415v,50hz,3ph,o/l relay range -4 to 6.5 a,cat no-ss 96210poto, l&t- make, auxiliary contactor, type : mn 0-31 e, 3 no + 1 nc, ue: 415 v, ie: 4 a, ui: 690 v, ith: 10 a, ac-15, coil voltage : 110 v ac, l&t- make, auxiliary contactor, type : mn 0-22 e, 2 no + 2 nc, ue: 415 v, ie: 4 a, ui: 690 v, ith: 10 a, ac-15, coil voltage : 110 vac, contactor type ml.1.5, 25 amp, 230v, operating coil voltage, l&t catalogue no 5591857, l&t make um -no, l&t make,3pole power contactor in open execution type ml-2 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 32a cat.no.ss 90701, l&t make 415v switch gear (acb), l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make power contactor type ml-4 with 2 no + 2 nc aux. contact, coil voltage 220v ac, ac-3 70 amp. rating, cat. no.-ss 90910, l&t make power contactor type ml-6 with 2 no + 2 nc aux. contact, coil voltage 220v ac, ac-3 110 amp. rating cat/. no-ss90921, power contactor,tp,ac-3 duty,coil voltage-240 v ac,type: mnx-40, l&t make 3 pole power contactor, type mnx45, ac-3 phase, rating 45a, coil voltage- 415 v ac, along with 2 no+2 nc, l&t make 3 pole power contactor with coil, type mnx 70, ac-3 rating 70a, coil voltage 415 v ac, cat.no.cs97076 suffix: d000, 220v dc auxiliary contactor 2no+2nc cat no : tca3 dn22, 220v dc auxiliary contactor 4no cat no : tca3 dn40, ml 4 con. kit set cat no ss 91660 l & t make, spare coil for ml10/ml11/ml12 contactor cat. no. ss91011, make - l & t, thermal over load relay 2.5-4 a (l&t) 678109, l&t make bi metal o/l relay type ml range 6.0-10a , cat no ss 9185800vo, l&t make 415v switch gear (acb), l&t make thermal over load relay with alarm contact.type : ml - 1, catlouge no ss91858,amp. range : 10.0 to 16.0, l&t make bi metal o/l relay for ml -2 range 13-21a , cat no ss 9185900co, l&t make 415v switch gear (acb), thermal o/l relay(l&t) range:20 to 32a,type:ml 2/3 relay,cat no:ss 91859, bimetel overload relay range 28-42 amp., bimetal thermal overload relay, range: 30-50a, l & t make auxiliary contact block,mx-a1 11e (aux contact block) 1 no + 1 nc, add-on auxiliary contact block suitable for auxiliary contactor, front mounting, make : l & t, type : mx-a1-22e, 2 no + 2 nc, ue: 415 v, ie: 3 a, ui : 690 v, ith : 10 a, ac-15, addon block contact make: l&t ,mnxa2(1no+1nc contact) ui-415 ,ith-10a ,ie-4a ac15, l&t make aux contact add-on of mnx type contactor for 2no + 2nc cat no:- cs94114, l&t make 3-position selector actuator (switch) catalogue no. ss91517, auxi block type :3tx 4 010 -2a :1 no, auxi blocktype :3tx 4 001-2a :1 nc, contact block
Tender For complete set installation commissioning and testing of gas pressure type buchholz relay,winding temperature and oil temperature protection relay with alarm,tripping indicates of 2 mva 6.6kv/3.3 kv gecmake transformer sl no 32917cocp substation of ama
Tender For inspection and checking the healthiness of 11 kv, 630a, vacuum circuit breaker, its protection system (cts, lockout and idmt relay) of colony feeder at cooling tower area for put back into service