Tender For bid to ras supply of supply of split type ductable, air cooled 5.5 tr ac plants each comprising of i indoor unit and outdoor condensing unit , pedestal stand support for odu idu at chintapalli , copper line at the rate 5metre per each unit at chintapalli , drain pipe at the rate 7.5 metre per each unit at chintapalli , electrical cable at the rate 5metre per each unit at chintapalli , control cable between indoor and outdoor at the rate 5metre per each unit at chintapalli , duct damper 01 number per unit at chintapalli , erection, commissioning and testing of the plant at chintapalli , supply of split type ductable, air cooled 5.5 tr ac plants each comprising of 1. indoor unit and outdoor condensing unit at nandyal , pedestal stand support for odu idu at nandyal , copper lineat the rate 5 metre per each unit at nandyal , drain pipe at the rate7.5 metre per each unit at nandyal , electrical cable at the rate 5metre per each unit at nandyal , control cable between indoor and outdoor at the rate 5metre per each unit at nandyal , duct damper 01no. per unit at nandyal , erection, commissioning and testing of the plant at nandyal , supply of split type ductable, air cooled 5.5 tr ac plants each comprising of i indoor unit and outdoor condensing unit at vellore , pedestal stand support for odu idu at vellore , copper line at the rate 5metre per each unit at vellore , drain pipe at the rate7.5 metre per each unit at vellore , electrical cable at the rate 5metre per each unit at vellore , control cable between indoor and outdoor at the rate 5metre per each unit at vellore , duct damper 01no. per unit at vellore , erection, commissioning and testing of the plant at vellore , supply of split type ductable, air cooled 5.5 tr ac plants each comprising of i indoor unit and outdoor condensing unit at yercaud , pedestal stand support for odu idu at yercaud , copper line at the rate 5metre per each unit at yercaud , drain pipe at the rate 7.5 metre per each unit at yercaud , electrical cable at the rate 5metre per each unit at yercaud , control cable between indoor and outdoor at the rate 5metre per each unit at yercaud , duct damper 01no. per unit at yercaud , erection, commissioning and testing of the plant at yercaud
Tender For supply, installation, testing and commissioning of extra material for installation of unitary acs in different departments /centers/schools, office etc. at iit kharagpur, kharagpur (phase i). - "supply, installation, testing and commissioning including vaccumization and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for split ac system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required :note: wall opening and making good to the damages.", "6.4 mm (¼"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "9.5 mm (⅜"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "12.7 mm (½"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "15.86 mm ( ⅝"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "19 mm (¾"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", interconnection electrical copper cables from indoor , outdoor & electrical control panel complete with 4 core 2.5 sqmm copper frls insulated cable(isi marked) with cable tie & clamp etc as required., supply & installation m.s epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement., supply & installation of upvc drain pipe (isi marked) with 6mm thick nitrile rubber insulation from idu - 25mm dia, 40 mm rigid upvc drain pipe (isi marked) with 6 mm thick nitrile rubber insulation complete with fittings, u traps etc. & as specified to the nearest toilet with required civil works & finishing the same., supply of r-22 gas for top up, supply of r-32 gas for top up, supply & installation of good quality wooden frame (2" x 2") thick required for window ac installation, supply & installation of 16amps plug top (isi marked), supply & installation of 100mm pvc trunking with snap on trunking (isi marked), "supplying and installing following size of perforated hot dipped galvanised iron cable tray with cover (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.", 100 mm width x 50 mm depth x 1.6 mm thickness, 225 mm width x 50 mm depth x 1.6 mm thickness, 300 mm width x 50 mm depth x 1.6 mm thickness, installation, testing & commissioning of the window ,split acs ,cassette ac supplied by department. price shall be inclusive of installtion upto 3mtr of refrigerant pipe, drain pipe and cable., window acs, split acs, cassette acs, tower acs, reinstallation, lifting, shifting of existing ac units (split & window acs & cassette ac)., window acs, split acs, cassette acs, tower acs, dismantling of existing ac (split ac / window ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (cassette ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (tower ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, buy-back of existing unserviceable ac (split ac / window ac/cassette ac) units(all type) including all copper pipes, drain pipes mounting surfaces, etc. complete. the item shall be quoted as negat