Tender For purchase of equipments ( s.no 1 to s.no 5 ) for civil department - purchase of equipment s, sand replacement test apparatus metal tray / base platesquare metal tray with a central hole (e.g., 300 mm 300mm with 100 mm hole). another common size: 450 mm square, 50 mm deep with 200 mm central hole for larger kitsseamless steel cylinder with no sharp edges. common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1wall thickness ~3 mm (industrial products) common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1 wall thickness ~3 mm (industrial products), core cutter aim 161 model core cutter: seamless steel tube (typically 100mm id, 130mm height, 3mm wall thickness). steel dolly: 25mm high, 100mm id, to prevent damage while driving. steel rammer: for driving the cutter. tools: spade, straight edge (knife), moisture containers. , slump cone apparatus 300mm ht, bottom dia 200mm,top dia 100mm with base plate andtamping rod material make : mild steel, jar test apparatus uniform stirring of up to 6 samples simultaneously. stirring rods should be adjusted individually during mixing digital display which should clearly indicate the speed of rotational variable speed 1-200rpm. heavy duty 1/20hp motor with gear train mounted on a mild steel housing. stainless steel stirring paddlers with adjustable height. paddles to be driven by electronically controller variable speed. locking collars or stirring rods permit adjustment height of paddle height. spacing of 6 (150mm) between stirring rods so as to permit use up to 1000ml beaker. the digital timer to be set to count down from 1 to 99 minutes. housing material: crc / ms sheet duly powder coated. power consumption : 220/230v ac supply 50hz single phase motor : 1/ 20hp motor good quality illumination : built in illuminator beaker : 6 nos 1000 ml beaker 1, compression testing machine 1000kn capacity capacity: 1000 kn type: hydraulic,floor-mounted accuracy: 1% of indicated load load application:smooth, uniform, controlled platens:hardened steel platens, suitable for concrete cubes/cylinders safety:overload protection, pressure relief valve, emergency stop, safety guard standards: is 516 / astm / iso compliant power supply: 415 v, 3-phase, 50 hz accessories: platens,spacers, pressure gauge, operating manual calibration: factory calibrated with certificate installation & training: included
Tender For corrigendum : purchase of surgical items and sutures at bundi - surgical and sutures, absorbable gelatin sponge ip 66, size 80(+-10) mm x 50 mm x 10 mm should be sterlized., asepto syringe with transparent bulb sterile, 60 ml, blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate should conform to is 9824(part 3):1996, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered,,without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should co
Tender For e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497for particular size., sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size16 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation symmetrical foley balloon balloon capacity 30 1 ml should conform to is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size18 fg. made of silicone elastomer bonded with latex. should have hard plastic valve. smooth distal end with s
Tender For supply of 2026-27 (gr. hicc n 08) bio medical waste sharp white disposable containers 60 litres plastic body rectangular shapes, puncture and leak proof, tamper proof with lid handle type (02 items clubbed) ]