Tender For procurement of iv cannula with injection port 20g. spec: 1. disposable, sterile, single use, individually transparent packing. 2. size - 20 g, effective length 19 - 50mm, colour code according to size, minimum flow rate 35ml/min. 3. should have injection port, snap lid on port, leak proof, must be leur fitting. 4. adaptable fixation wings. 5. material: polyurethane (pur). 6. should be non-thrombogenic, non-toxic and non pyrogenic, haemo and thermo compatible. 7. needle: a. the inner needle must have a universal back cut bevel for minimal puncture trauma, wide choice of insertion angles, insertion with less tissue tearing (v-cut). b. blood flow through needle must be adequate to ensure immediate flow. 8. cannula should be: a. thin walled. b. x - ray/radio-opaque line for determination by x-ray. c. smooth surface. d. kink proof. e. softens at tissue and body temperature in situ. 9. bp/iso/isi /ce standards 10. removable flash plug withhydrophobic membrane. 11. dhep free, latex free, pvc free. 12. bidder must provide brochure of the product they are intending to supply with clearly mentioning the materials and other specs. 13. compliance letter without valid document will not be accepted as bid. [ai(2026-27), item code-no: s-51028, sl no.26] ]
Tender For supply of low flux dialyzer with facility for head end opening to facilitate dialyzer cleaning. spec: 1. dialyzer with facility of both end opening. 2. diameter: 1.3 m2-1.8 m2. 3. material of the membrane: polyneprone/polyethersulfone. 4. priming value: 80-130 ml. 5. effective length: 220-280 mm. 6. inner diameter: 190-220 m. 7. membrane thickness: 38-42 m. 8. sterilization: gamma. 9. maximum tmp: 500 mmhg. 10. header material: polypropylene. 11. housing material: polypropylene. 12. potting compound: polyurethane. 13. clearance on 200 blood flow and 500 dialysate flow: i. urea: 180-200. ii. creatinine: 170-200. iii. phosphate: 140-180. iv. vitamin b12: 80-120. v. kuf (ml/hr/mmhg): 10-25.[ai(2026-27), item code-no: s-58030, sl no.523] ]
Tender For supply of general printing item in kandi s.d hospital - forms single side , forms single side , bi-color , er-ticket , er-ticket (both side) , register , register , register , visiting card , froms , forms single side , bi-color , blood bank , cross match , forms , usg/diet , requisition forms , board (both side) , attendance , register , usg/diet , requisition forms , best quality paper , sncu slip , other forms + board printing , forms single side , forms single side , bi-color , stamp (small size)
Tender For supply of pu full gloss enamel (two pack ) for the exterior finishing paint of railway coaches confirming to rdso spec no.m&c/pcn/100 /2018.chapter v, color shade blood red to ral 030 30 45 with rdsos amendment no.1b as an additional requirement. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For iv cannula with injection port 22g. spec: 1. disposable, sterile, single use, individually transparent packing. 2. size - 22 g, effective length 19 - 50mm, colour code according to size, minimum flow rate 35ml/min. 3. should have injection port, snap lid on port, leak proof, must be leur fitting 4. adaptable fixation wings. 5. material: polyurethane (pur). 6. should be non-thrombogenic, non-toxic and non pyrogenic, haemo and thermo compatible. 7. needle: a. the inner needle must have a universal back cut bevel for minimal puncture trauma, wide choice of insertion angles, insertion with less tissue tearing (v-cut). b. blood flow through needle must be adequate to ensure immediate flow. 8. cannula should be: a. thin walled. b.x - ray/radio-opaque line for determination by x-ray. c. smooth surface. d. kink proof. e. softens at tissue and body temperature in situ. 9. bp/iso/isi /ce standards, 10. removable flash plug with hydrophobic membrane. 11. dhep free, latex free, pvc free. 12. bidder must provide brochure of the product they are intending to supply with clearly mentioning the materials and other specs. 13. compliance letter without validdocument will not be accepted as bid. [ai(2026-27), item code-no: s-51029, sl no.27] ]
Tender For lab reagents and xray item purchses - abx cleaner (horbia 3part cbc) , abx lysebio (horbia 3part cbc) , abx minidile (horbia 3part cbc) , abx minoclair (horbia 3part cbc) , probe cleaner (labtech lt360) , lt 360 lyse solution (labtech lt360) , lt 360 diluent (labtech lt360) , urine albumin sugar strip (span aspen) , auto pipette 10 to 100 micro liters , auto pipette 5 to 50 micro liters , auto pipette 5 to 50 micro liters , auto pipette 100 to 1000 micro liters , blood group anti serum abd (j.mitra, meril) , blue tips 100 το 1000micro liter used for pippete , yellow tips 5-50 and 10-100 micro liter used for pippete , clotting capilary tube used for ct test , biochemistry test for used erba kit b.sugar , biochemistry test for used erba kit b.urea , biochemistry test for used serum creatinine , biochemistry test for used serum billirubin (t) and (d) , biochemistry test for used serum s. got , biochemistry test for used serum s. gpt , biochemistry test for used serum serum alk. phosphetase , biochemistry test for used serum serum total protein , biochemistry test for used serum serum albumin , biochemistry test for used serum serum cholesterol , biochemistry test for used serum s. triglyceride , biochemistry test for used serum s. hdl , biochemistry test for used serum s. vldl , cotton roll , cover slip , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , erba wash , esr disposable tube with vaccum plug , field stain a and b (diagnostic, organo, aspen) , glass slide 76mm *26mm , gloves 7 and 7.5 , glucometer battery cell , 1glucometer+1000 strip (accu-chek instant, dr morepen bg-3) , hb (hemocque 301) micro cuvette , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , jsb stain ist (ases, aspen, dig.) , jsb stain iind (ases, aspen, dig.) , k3 edta vial double cap , lancet , liquid peraffine oil , lugol iodine solution (spam, j.mitra) , malaria card (sd bioline, meril, j. mitra) , needle 22 no. , peri pheral blood semar fixative , print roll for cbc and analyzer , ria tube , sodium citrate 3.8% , sodium hypo cloride solution , spirit 70% , syrings 3ml(dispo/pricon) , syrings 5ml(dispo/pricon) , test tube brush , test tube glass borosil 6 inch , test tube plastik without capplain , tissue paper roll , biochemistry test for used serum serum albumin , biochemistry test for used serum serum cholesterol , biochemistry test for used serum s. triglyceride , biochemistry test for used serum s. hdl , biochemistry test for used serum s. vldl , cotton roll , cover slip , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , erba wash , esr disposable tube with vaccum plug , field stain a and b (diagnostic, organo, aspen) , glass slide 76mm *26mm , gloves 7 and 7.5 , glucometer battery cell , 1glucometer+1000 strip (accu-chek instant, dr morepen bg-3) , hb (hemocque 301) micro cuvette , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , jsb stain ist (ases, aspen, dig.) , jsb stain iind (ases, aspen, dig.) , k3 edta vial double cap , lancet , liquid peraffine oil , lugol iodine solution (spam, j.mitra) , malaria card (sd bioline, meril, j. mitra) , needle 22 no. , peri pheral blood semar fixative , print roll for cbc and analyzer , ria tube , sodium citrate 3.8% , sodium hypo cloride solution , spirit 70% , syrings 3ml(dispo/pricon) , syrings 5ml(dispo/pricon) , test tube brush , test tube glass borosil 6 inch , test tube plastik without capplain , tissue paper roll , envelopes x-ray (8x10) , envelopes x-ray (10x12) , envelopes x-ray (12x15) , x-ray film (free-8x10 , x-ray film (manul-10x12) , x-ray film (free-12x15) , delopar , fixer , digital film(8x10) , digital film (10x12)