Get complete information related to latest Amplatz Stiff Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amplatz Stiff Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amplatz Stiff Wire Tenders.
Tender For corrigendum : rate contract procurement of consumables and drugs for the department of neonatology-, disposable neonatal ventilator circuit, single heated limb with disposable humidifier chamber with appropriate connectors., disposable neonatal ventilator circuit, double heated limb with disposable humidifier chamber with appropriate connectors., disposable neonatal nasal masks (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal nasal masks (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal nasal masks (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal nasal masks (silicon) far non invasive ventilation (c-pap, nimv), , disposable neonatal nasal masks (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal short binasal prongs (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal short binasal prongs (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal short binasal prongs (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal short binasal prongs (silicon) for non invasive ventilation (c-pap, nimv), disposable neonatal bonnet/cap for non invasive ventilation (c-pap. nimv), disposable neonatal bonnet/cap for non invasive ventilation (c-pap. nimv), disposable neonatal bonnet/cap for non invasive ventilation (c-pap. nimv), disposable neonatal bonnet/cap for non invasive ventilation (c-pap. nimv), disposable neonatal bonnet/cap for non invasive ventilation (c-pap. nimv), disposable neonatal connecting tube/interface for non-invasive ventilation (c-pap, nimv), , disposable neonatal fixation strips of bonnet for non-invasive ventilation (c-pap, nimv)., 1. should be made up of soft skin friendly material. adhesive tape on both ends., 19, 6.1, heated humidifier high flow cannula for new borm, 2. it should have soft velcro, around 15 cm, 1. it should be flexible gas tube made of ss coil spring and medical grade polyolefin, tube, 2. it should be non-kinkable design with soft and smooth end cannula, 3. should have skin friendly adhesive for cannula, extra small, 34, 20, 6.2, heated humidifier high flow cannula for new born, tube 2. it should be non-kinkable design with soft and smooth end cannula, 1. it should be flexible gas tube made of ss coil spring and medical grade polyolefin, 3. should have skin friendly adhesive for cannula, small, 36, surgical consumable items, surgical consumable items, surgical consumable items, 21, 6.3, heated humidifier high flow cannula for new born, 22, 7.1, umbilical catheter polyurethane, 23, 7.2, umbilical catheter polyurethane, 35, 24, 7.3, umbilical catheter polyurethane, 25, 7.4, umbilical catheter polyurethane, 26, 7.5, umbilical catheter polyurethane, 36, 27, 8.1, 28, 8.2, 1. it should be flexible gas tube made of ss coil spring and medical grade polyolefin, tube 2. it should be non-kinkable design with soft and smooth end cannula, 3. should have skin friendly adhesive for cannula, 1. radiopaque umbilical polyurethane catheter, distal tip is printed numerically from 4 to 25 cm. transparent hub, 1. radiopaque umbilical polyurethane catheter distal tip is printed numerically from 4 to 25 cm. transparent hub, 1. radiopaque umbilical polyurethane catheter distal tip is printed numerically from 4 to 25 cm. transparent hub, 1. radiopaque umbilical polyurethane catheter distal tip is printed numerically from 4 to 25 cm. transparent hub, 1. radiopaque umbilical polyurethane catheter distal tip is printed numerically from 4 to 25 cm. transparent hub, peripheral inserted central catheter for neonate (picc line), catheter markings every centimetre 3.should have fixation wings and 4.introducer integral extension tube, length of extension tube (pur) 8 cm, 2. actual distance from the 3. should be in sterile packing4,, 2. actual distance from the 3. should be in sterile packing4., 2. actual distance from the 3. should be in sterile packing4., 2. actual distance from the
Tender For medical attendance pass, size: 12 inch x 5.2/3 inch, (books) with 100 lvs. having both side print on 58 gsm ir logo white water mark security paper in black ink. printing instructions: : printing with raw material. text matter with both side printing in bilingual (hindi and english) text matter printing in black colour ink numbering to be machine serial numbered on right top corner (in quadruplicate on same page i.e. on 04 counter foils) in 6 digits and as per serial number allotted. in no case the number shall be printed on dot matrix/inkjet or laser jet printers. raw material:- for text printing over 58 gsm ir logo white water mark security paper conforming to is 1848/2007 as amended up to 2018 for cover page kraft paper 130 gsm conforming to is 1397/90 or latest grade- ii binding specifications: 100 leaves (in quadruplicate on same age) limp bound with two side pins on left side of cover page. one seal pin on right bottom corner supply should be in a bundle of 25 nos. each with strapping. numbering instructions: the commencing no. is to be obtained from amm (sty) by. manuscripts to be get approved from amm (sty)/ by.
Tender For corrigendum : supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exha
Tender For providing installation testing and commissioning of a medical grade online double pass reverse osmosis ro plant of 500 liters per hour capacity double pass along with allied works for the hemodialysis unit at chc parole district kathua