Tender For biennial rate contract for road transportation of electrical equipment, materials, including loading, unloading and proper stacking from zonal testing unit, siliguri to abhikhan, wbsedcl, saltlake, kol-91, wbsedcl and vis-a-vis,2nd call
Tender For corrigendum : supply of various medical equipment in ptpp, parichha, jhansi (up)-284305. - 30-40 watt uv tube insect, fly and mosquito killer machinecompany name_1-weird wolf2-i bell3-wi note k, heat therapy lamp , infrared pain relief lamp (with heating and timing controller) 150 wattscompany name_1- beurer2- acu-physio3-perfecxa, 4 channels, 70 programmes ,interferential therapy machine with led displaycompany name_1-physio trust2-physiogears mini3-physiotrex4-medgears, electrical needle destroyer machine for hospital & laboratory,company name_1-weird wolf2-i bell m2313-welimark electric needle, air purifier and covering 500 sq.ft or more uv led & lonizer, anti-bacterial, activated carbon & h13 hepa filter with long lasting filtercompany name_1-coway air mega 1502-philips smart air purifier3-haney well4-bluestar, 12 channel bpl cardiart 9108 fully automatic ecg machine with interpretationcompany name_1- bpl, 3 mega hartz ultrasonic machine with timer for physiotherapycompany name_1-physiotrex2- physiogears3-ultracare pro4.physiolife care, 4 channel fully automatic with led display tens machine for physiotherapycompany name_1-physiogears2- physio track3- physio trust
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - establisment pediatric care unit at dh godda; pipelines, furniture, electrical system or installation, medical equipment and devices, hvac, renovation; bidder
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For supply and installation of general and medical equipment along with plumbing work, electrical and civil work for new i.p.d. and new o.p.d. in mbs hospital kota on turn key basis
Tender For corrigendum : supply and delivery of bought-out materials with composite work for utilities offsites part b for iocl panipat refinery expansion p25 project - supply of 900 mm wide safety insulation mats complying to is-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all materials, as per applicable indian or international standards and cea guidelines
Tender For providing technical services for carrying out the operation and maintenance of electrical sub station ess ht or lt panels associated equipment dg sets water treatment plant wtp and sewerage treatment plant stp for period of 24 months for ap high court buildings at nelapadu amaravati