Get complete information related to latest Analysis System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Analysis System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Analysis System Tenders.
Tender For corrigendum : supply of steam water analysissystem main spares and e and c c c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , conductivity analyzer -online retractable type , sample handling system for main steam superheated , sample handling system for main steam saturated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for condensate cep outlet inlet cooling wtr , sample handling system for dm water , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 6 mandays at manufacture works and 6 mandays at site , mandatory spares as per tech specs , supervision of e and c services charges at site , supervision of e and c visit charges
Tender For procurement of lab equipments for mechanical engineering department. - procurement of lab equipments for mechanical engineering department., exhaust gas analyzer: portable 5 gas exhaust analyser for automotive lab use measurement of, co (0-10 %) co2 (0-20%) hc (0 20000 ppm) o2 (0-25%) nox (0 5000ppm) gas sampling rate 01 lit / min response time = 5 seconds warm up time =03 minutes display lcd input membrane keyboard operating temperature - 0- 50 degree celsius power consumption 25 w, operates on 230 v ac / battery supplied with sampling probe, filters, and carrying case, 3d printer: build volume (wxdxh) 256 x 256 x 256 mm * shell enclosed (plastic & glass) hot end all-metal nozzle 0.4 mm stainless steel included max hot end temperature 300 nozzle diameter 0.4 mm (included) 0.2 mm, 0.6 mm, 0.8 mm (optional) build plate compatibility textured pei plate, cool plate, engineering plate, high temperature plate max build plate temperature 100 max speed of tool head 500 mm/s max acceleration of tool head 20 m/s supported filament pla, petg, tpu, pva, pet, abs, asa chamber monitoring camera low rate camera 1280 x 720/0.5fps time lapse supported filament run out sensor yes control board fan closed loop control auxiliary part cooling fan closed loop control air filter activated carbon filter, mitutoyo screw thread micrometer (0 -25 mm) mitutoyo screw thread micrometer 0 25 mm range; 0.001 mm accuracy; 0.005 mm/0.01 mm resolution; interchangeable anvils & spindle tips for multiple thread forms hardened measuring faces ratchet stop; calibration certificate protective case