Get complete information related to latest Angle Bracket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Angle Bracket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Angle Bracket Tenders.
Tender For tender for supply of renovation of old substation for utilization as maintenance office : : - providing and applying fibre reinforced elastomeric liquid water proofing , demolishing brick work , making the opening in brick masonry of wall , dismantling doors of area 3 sq meters and below window , dismantling doors of area 3 sq meters and above window , reinforced cement concrete work in chajjas etc , steel reinforcement for rcc work , centering and shuttering including strutting propping etc , shifting filling compaction of available malwa , supplying and filling in plinth with sand under floors , providing and laying in position cement concrete , providing and laying vitrified tiles in wall floor , providing and laying of 25 mm thick kota stone slab flooring , providing and fixing tiled false ceiling of specified materials , dismantling old plaster or skirting raking out joints , 12/15 mm cement plaster , removing dry or oil bound distemper , providing and applying white cement based putty , distempering with 1st quality acrylic distemper , finishing walls with acrylic smooth exterior paint , providing and fixing aluminium work as per item a and b , providing and fixing float glass panes of 5 mm thickness , providing and fixing 12 mm thick prelaminated particle board , providing and fixing aluminium american handle , providing and fixing aluminium universal hydraulic door closer , providing and fixing bright lock with 6 levers , providing and fixing aluminium tower bolts 250x10 mm , providing and fixing aluminium tower bolts 150x10 mm , providing and fixing double action hydraulic floor spring , providing and fixing sliding device for aluminium door , making plinth protection 50mm thick of cement concrete , brick work with common burnt clay modular bricks below plinth , brick work with available bricks with cleaning of old mortar on site in plinth and foundation , brick work with common burnt clay bricks above plinth , providing and laying in position cement concrete m20 , providing and fixing gi chicken wire mesh , providing and laying 60 mm thick faciory made cement concrete , wiring for light point fan point exhaust fan point call bell point , supplying and drawing following sizes of frls pvc insulated copper conductor 3x2 5 sqmm , supplying and drawing following sizes of frls pvc insulated copper conductor 3x4 sqmm , supplying and fixing gi box with fixing 6 pin 5 6 15 16 a modular socket outlet and 15 16 a , wiring for group controlled looped light point fan point exhaust fan point call bell point , supplying & fixing gi box with 25a modular socket outlet and 25a modular sp mcb c , supplying and fixing following way three pole and neutral mcb distribution board , supplying and fixing 5 a to 32 rating 240 41 5 v 10ka c curve , supplying and fixing following rating four pole 415 v isolator in the existing mcb db , earthing with g l earth plate 600 mm x 600 mm x 6 mm , supplying and laying 25 mm x 5 mm g i strip , supplying of following sizes of 1point 1 kv grade multicore aluminium conductor , supply and installation of recess led lights in false ceiling 36 watts , supply and installation of 22 watt led batten , supply and fixing of 400 450 mm sweep wall bracket fan , supply installation and commissioning of 1200 mm sweep ceiling fan
Tender For tender for work of decoration item at modasa nagarpalika - sealing (cloth), wall (cloth), floor (cloth), hallway sheet, tack with cloth, all dredge pole, heater, places for lighting with electric, socket, price of 1 running meter, price of 1 running meter, clothes, with flex banner/, mic set, socket, 1 meter, price per sq.m. mattress, table, ceiling fan, sound speaker, light, blanket, couch, cupboard, halogen white 400 watt, v ????ru shi .pi., generator set – 1 price of keeping a tea generator set – 1 all , podium , ganesh vishwamitra mat , purpose of making a pond , water , flooring mud pot , poi , high , side , sofaset , seat , sofaset vip , soft cloth (sheet) , red cloth , serial , running belt , price of a lease / , touch digital light , with led ???? , led , lasma tv set , dash tv set , telephone backlight , lavender decoration , lug point board , pa light , wi-fi system
Tender For corrigendum : tender for supply of item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , s/f diesel filter with o ring (primary) 200kva dg , s/f lub oil filter with o ring 200kva dg , s/f diesel filter with o ring (secondary) 200kva dg , s/f engine oil(mobil) 200kva dg , sevicing by authorised dealer /oem for 200kva dg set , s/f diesel filter with o ring (primary) 160kva dg , s/f lub oil filter with o ring 160kva dg , s/f diesel filter with o ring (secondary) 160kva dg , s/f engine oil(mobil) 160kva dg , sevicing by authorised dealer /oem for 160kva dg set
Tender For corrigendum : tender for supply of operation and comprehensive maintenance of ems at kadma te build jsr d d - as per item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , sf pvc junction box along with 150 amp 4 way connectors , suppllying xlpe 1.1 kv al 4x10 sqmm cable , suppllying xlpe 1.1 kv al 2x6 sqmm cable , laying of xlpe cable in ground , laying of xlpe cable on wall surface , laying of cable existing rcc/ hume/ metal pipe , sh 40 mm dia g.i pipe medium class ias per nit. , sm end term with brass gland and alum lugs 4 x 10 sq. mm , sm end term with brass gland and alumi lugs 2 x 6 sq. mm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl. 400a fp mccb , 36ka overload rel , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required. , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , supply and replacement of 45 watt street light , supply and replacement of 27 watt street light , dehyd filt & testing of existing trasformer , supplying of new transformer oil , replacement gasket of transformer , replacement lt side stud bush , painting of transformer with good quality synthetic paint , s/f diesel filter with o ring (primary) 160kva d e/a set , s/f lub oil filter with o ring 160kva d e/a set , s/f diesel filter with o ring (secondary) 160kva d e/a set , s/f engine oil(mobil) 160kva d e/a set , sevicing by authorised dealer /oem for160kva dg set
Tender For maintenance of e.i in rb at chandigarh.(providing lawn lights in house no. 68 (type-dmh) sector-7, chandigarh. (e.i. wrok). - dsr item no. 1.10 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required., group b, dsr item no.1.31 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required., dsr item no.1.32 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., dsr item no. 1.17 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, dsr item no.1.21 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 20 mm, 25 mm, dsr item no. 1.33 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required., dsr item no.1.26 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., dsr item no.1.25 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., dsr item no. 2.16 supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required., dsr item no. 8.9.5led batten light (system lumen efficacy 105 120 lm/watt)supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, (as per complete item no. 10 of the dnit)., 18- 22 watt, supply and erection of b.l. holder of make anchor panta / havells reo/ gold medal essenza isi marked on existing jn. box / wooden block including making connection etc as required., s/e of led bulk head luminaries weather proof frosted light with pmma / pc reflector and silicon gasket to be installed on surface. the led fitting should have minimum system lumen output minimum 1000 lumen and the driver of the fitting should be workable on 140-260 volt. (as per complete item no. 12 of the dnit)., supply & laying of pvc copper wire 1.5mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of engineer-in-charge. the copper wire should be of polycab/ l&t/ havells/ finolex/ r.r. kables make only., supply & erection of fresh air fan high speed motor with copper wound 10 sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of havells make ventiliar dx white / orient make ventilator / crompton make brisk air/ bajaj make 70049 250mm sweep only. (as per complete item no. 14 of the dnit)., s/e of led 8w/ 9 w. bollard fitting. the bollard should be approximately (800 mm long and 200 mm wide) from the top of the fitting. the bollard should be made out of extruded aluminium profile and die cast aluminium base with pmma/ opal diffuser bollard painted with superior quality of paint. (as per complet
Tender For maintenance of e.i in rb at chandigarh. (addition/ alteration of e.i in house no. 83, sector-23, house no. 320 and 3947, sector-22, chandigarh). - dsr item no. 1.15rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /pvc conduit including dismantling as required., group a., group b., dsr item no. 2.18 supplying and fixing 20amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., dsr item no. 1.16rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required., dsr item no. 1.17supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, 3 x 4 sq. mm, dsr item no.1.21supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25mm, dsr item no.1.23supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required., 5/6 amps switch, 2 way 5/6 a switch, 3 pin 5/6 a. socket outlet, dsr item no. 1.29 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required., dsr item no. 1.30 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required., dsr item no. 1.33supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required., dsr item no.1.38 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required., dsr item no.2.3 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator), 12 way, double door, dsr item no. 2.4 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb/ rccb/ isolator)., 4 way (4 + 12) double door, dsr item no. 2.10 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole, double pole, triple pole and neutral, supply and erection of electronic step type socket type fan regulator in existing b.l. sheet including making connection and petty material reqd. to complete the job. the fan regulator should be of anchor panta / havells reo/ gold medal essenza make only., supply and erection of b.l. holde
Tender For corrigendum : supply of spare/accessories items of two nos. multi-purpose fire tender(rj-28ea-0956 and rj-28-ea-0957) - 1 high pressure hose reel with 60mmlg x 19 mm (ø) with fog gun and spray type , 2 low pressure hose reel with 19 mm ø x 50 mm long hose with duel purpose shut off nozzle. 3 extension ladder 10.5 metre , 4 delivery hose 63 mm rubber lined in 30 m length (type a of is 636/79/5) complete with instantaneous coupling. , 5 long line 50 mm circumference 30 m long as per is 1084 , 6 short line 50 mm circumference 15m length as per is 1084 , 7 protective clothing for fireman complete with golves,boots,helmets with suitable face shield made out of material capable of reflecting at least 95% of radiant heat temperature around 1500 to 2000 degree celsius and also afford some protective against direct flame.the suit will be of sufficient size to accomodate a breathing apparatus to users (item should be packed in hard body box). , 8 fire hook , 9 fire man axe , 10 sledge hammer , 11 carpenter saw , 12 pick axe , 13 ceiling hook , 14 crow bar made of carbon steel , 15 self contained breathing apparatus (45 min duration compressed air type) complete with spare cylinder & tool kit) , 16 dividing breeching , 17 collecting breeching , 18 pvc suction hose heavy duty complete with copper alloy round threaded couplings to suit the pump inlet - 2.5m long. , 19 suction strainer for item 2 , 20 basket strainer suitable for item 4 , is : 3582 , 21 dividing breaching with control arrangement as per is : 5131 , 22 collecting breaching as is : 905 , 23 hose bandages rubberized is : 5612 , 24 hose clamps is : 5612 , 25 water curtain nozzle made of m .s .plate with g . m instantaneous connection , 26 branch pipe short ( chromium plated) is : 903 , 27 a set nozzle of sizes 12 mm , 16 mm , 20mm , 25 mm and 32 mm ( two each ) ( see is : 903 - 1975 * t ) , 28 adapter for 100mm suction female thread and 63mm male instantaneous 29 adaptor double female instantaneous pattern 63mm . , 30 adaptor double male instantaneous pattern 63mm , 31 hand lamp ( 4cells ) , 32 rubber gloves 33kv 1 pair , 33 fire beater , 34 foam pick up tube , 35 rubber gloves as per is 4770 - 1991 for 5000 volts , 36 leather gloves is 6994 – 1977 , 37 jack hydraulic for 20 ton capacity with handle , 38 hand controlled branch for 63 mm size hose coupling , 39 hand held fast action select flow nozzle :-the selectable flow rate multipurpose nozzle should have a multiple flow setting. this product be of light in weight and easy to handle. weight of the nozzle should not be more than 2 kg. the calibrated flow rates are easily selectable through an selection ring. the stream patterns should be changed by rotating the diffuser head ring. nozzle should be having pistol grip, shut off ball valve opening and made of aluminum alloy. , 40 bolt cutter – 600mm long , 41 shovel with handle , 42 minimum 12v halogen fog & spot lamps , 43 hose ramp
Tender For supply of supply of stand mounted fabricated prefabricated sub main distribution board smdb , itc and labelling of floor mounted pre fabricated , supply of surface recess , itc of pre fabricated 3 phase 415v 6 way tp surface , supply of pre fabricated 240 v rated 6 way , itc of pre fabricated 240 v rate 6 way sp , supply of 4 pole 160a manual changeover switch disconnector , itc of 4 pole 160a manual changeover switch disconnector with terminal shrouds , laying of pvc insulated and pvc sheathed xlpe , laying of pvc insulated and pvc sheathed xlpe power cable , laying of one number pvc insulated and pvc sheathed xlpe , supply of 4c x 10 sq mm stranded copper conductor , laying of 4c x 10 sq mm stranded copper conductor , supply of indoor end termination , making indoor end termination , supplying 300 mm width x 50 mm depth x 1 6 mm , installing 300 mm width x 50 mm depth x 1 6 mm , supplying 100 mm width x 50 mm depth x 1 6 mm , installing 100 mm width x 50 mm depth x 1 6 mm , supplying 25 mm x 6 mm g i strip , laying 25 mm x 6 mm g i strip , supply of 6 swg dia g i wire , fixing 6 swg dia g i wire , supply of maintenance free earth kit , itc of maintenance free earth kit , supply of frls pvc insulated stranded copper conductor , drawing of frls pvc insulated stranded copper conductor , supply of 20mm size of isi marked hgms ms black painted conduit , installation of 20mm size of isi marked hgms ms black painted conduit , supply of 25mm size of isi marked hgms ms black painted conduit , installation of 25mm size of isi marked hgms ms black painted conduit , supplying 1 or 2 module 75mmx75mm size gi box with modular base , fixing 1 or 2 module 75mmx75mm size gi box , supplying 4 module 125mmx75mm size gi box , fixing 4 module 125mmx75mm size gi box , supplying 6 module ) /bid number: gem/2025/b/6962998 * /dated: 09-12-2025 & & / bid document1 / 49 & & ' ' /item category200mmx75mm size gi box , fixing 6 module 200mmx75mm size gi box , supplying 8 module 125mmx125mm size gi box , fixing 8 module 125mmx125mm size gi box , supplying 5 6 amps modular switch , fixing 5 6 amps modular switch , supplying 3 pin 5 6 amp modular socket outlet , fixing 3 pin 5 6 amp modular socket outlet , supplying 15 16 a modular switch , fixing 15 16 a modular switch , supplying 6 pin 15 16 a modular socket , fixing 6 pin 15 16 a modular socket outlet , supplying 3 pin 5 a ceiling rose , fixing 3 pin 5 a ceiling rose , supply of 1 phase 230v 35w or better batten type , installation of 1 phase 230v 35w or better batten , itc of ceiling fan , supply of 300 mm sweep heavy duty size exhaust fan , itc of 300 mm sweep , supplying 20 a 240 v spn industrial type socket outlet , fixing 20 a 240 v spn industrial type socket outlet , supply of 2cx1 5mm2 copper extruded pvc inner sheath armoured , laying of 2cx1 5mm2 copper extruded pvc inner sheath armoured , supply of addressable photo thermal multi sensor smoke detector ivory , itc of addressable photo thermal multi sensor smoke detector ivory , supply of addressable flex manual call point , itc of addressable flex manual call point , supply of addressable intelligent wall mounted sounder strobe , itc of addressable intelligent wall mounted sounder strobe , supply of junction box with elmex type terminal block , installation of junction box at ceiling wall surface recess , integration of the fire detectors mcp sounders , dismantling of one 01 no existing floor mounted electrical panels , dismantling of cables of size upto 150 sq mm , dismantling of incoming cables of size 16 35 sq mm , dismantling and removing of existing switchboard industrial sockets , dismantling of existing g i strip upto size of 25mm x 6mm , dismantling of existing conduits sizes 20mm 25mm 32 mm , dismantling of existing fire detector mcp sounder fire panel