Web Analytics Made Easy - StatCounter

Angle Drive Spares Tenders

Get complete information related to latest Angle Drive Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Angle Drive Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Angle Drive Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations/Associations/Others

CTN :45532318 Due date: 09 Jul, 202609 Jul, 2026 19.50 Lacs
Tender For corrigendum : repair and maintenance work of foot path and light arrangements,eb board,play materials and name board works in tnhb p-iii park at ward no.33 zone -4 in tcmc - eangaging of man power for cleaning weeds and bushes at lawn areas cutting plants and grass including all labour charges etc complete, gardener 5 days 6 nos, mazdoor ist class, engaging of ac electric grass cutter on hire basis including hire charges transport charges and all labour charges etc complete, supply and fixing of childerns play materials including cost and conveyance and fixing and proper alingenement charges etc complete, slider, 2 seater swing, 4 seater see saw, supplying and filling in foundation and basement with river sand in play area in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification., supply and fixing of light pole 4 metre length single bracket pole with base plate (250 x 250 x 6mm)76.10mm od x 3.65mm thick x 4000mm length etc.,completed, supply and fixing of 30w led street light fitting with led on out door fittings including cost and conveyance and fixing charges etc complete, supply and fixing of synthetic moulded compound box for street light with 16 a mcb and connecterincluding cost and conveyance and fixing charges etc complete box-735+16 a mcb sp and neutral -382, supply and fixing of 4 sqmm pvc unsheathed copper cable including cost and conveyance and fixing charges etc complete , supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good sd 194, centering and shuttering charges for all pcc and rcc works using ms steel moulds and soffits strutting with casurina props 10-13 cm dia including cost and conveyance of all materials and including all labour charges etc complete, plain cement concrete 1;2;4 mix using 20 mm hbg iss metal including cost and conveyance of all materials and including all labour charges etc complete, supply and filling of on quarry rubbish 15 cm thick on each layer including cost and conveyance and all labour charges for filling and consolidation charges etc complete, cement concrete 1:5:10 (one cement, five crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard speci cation and as directed by the departmental of cers. -mixing by manual means, paving the oor with pre-polished concrete anti-skid tiles (required shape and design) of 20mm thick of approved quality and colour laid in accordance with is 1443 over a cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required cement slurry and mortar plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard speci cation and as directed by the departmental of cers. (the make and brand of the tiles should be got approved by executive engineer before use on works), supply and fixing of m.s grills with doors and windows with one coat of red oxide with primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification., supply and fixing of stone bench including cost and conveyance and fixing and proper alingenement charges etc complete, supply and delivery of ms kiosk of size 0.75m x 0.45m x 0.75m made up of ms angle of size 50mm x 50mmx 4mm alround covered with 16 gauge ms sheet and kiosk door made up of ms plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,(twad sor 2025-26 unicode wd-m1471 clau

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

CTN :45715693 Due date: 15 Jul, 202615 Jul, 2026 19.48 Lacs
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuum crystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate

CTN :45706513 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; fabrication and erection of 3 phase dsl bus bar system ryb 55 meter runway for supplying mill s overhead crane along with all the material ms angle busbar..

Central Government/Public Sector

CTN :45646693 Due date: 13 Jul, 202613 Jul, 2026 41.00 Lacs
Tender For certain repairs to water supply distribution lines and other connected items at zone c at mil stn bhuj and gandhidham under ge(a) bhuj - taking up u/s ac/gi/di/upvc water main (incl all fitting) with spigot & socket /ms pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 200 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and directed., all as per item 1 above but 150 mm dia bore complete all as specified and directed., all as per item 1 above but 100 mm dia bore complete all as specified and directed., all as per item 1 above but 80 mm dia bore complete all as specified and directed., all as per item 1 above but 50 mm dia bore complete all as specified and directed., material and labour di pipes of size 200 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed., material and labour di pipes of size 150 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed. note: di fitting /lead joint / tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site., all as per item 7 above but 100 mm dia bore complete all as specified and directed., supply and fixing in any length upvc pipe 150 mm dia pipe manufactured as per astm-d-1785 as per is-559, schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed., all as per item 9 above but 100 mm dia bore complete all as specified and directed., all as per item 9 above but 80 mm dia bore complete all as specified and directed., all as per item 9 above but 50 mm dia bore complete all as specified and directed., m&l di bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of pipe size upto 200 mm dia complete all as specified and directed. ( lead /gasket for fitting shall be measured and paid separately), s & f in repair upvc ball valves with operating handle (stop valve) of size 50 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., s & f in repair upvc ball valves with operating handle (stop valve) of size 80 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed., rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed., removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed., hard standing cutting/road cutting for laying of pipe and making surface good with pcc 1:3:6 complete all as specified and directed., taking down carefully cast iron sluice valve of size 80 mm to 200 mm bore from ci water mains, complete with all acessories complete all as specified and directed., s&f in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class p n 1.6, conforing to is 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water

CTN :45618469 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of telescopic boom repair , supply and fabrication of conveyor c section , sfic y bend , sfic of soap solution mixture capacity 1000 liter , purging unit to pneumatic conversion , sfic straight conveyor section without chain , supply of 75 mm ms angle , supply of 90 mm ms angle , supply of bolt , supply of angle fasterner , upgradtion of evacuation unit to upto 6 cylinders , ms fabrication work , sfic of 48 head carousel filling ss plate , supply of rotatory 2 inch for hst machine , inner outer adpoter of hst machine , supply of gun of hst machine

CTN :45587119 Due date: 27 Jun, 202627 Jun, 2026 81.8 Thousand
Tender For supply of anabond tube,flat patti,angle iron,10 ton hydraulic jack repair kit,3 ton hydraulic jack repair kit,jack wheel,seat cover tata yodha,body matting mg,everest end joint,rst ms socket,angle iron 2 and half inch,safety goggles,plasma nozzle,welding set connector,welding machine 200a mag mma 3 in 1

Co-operative

CTN :45551842 Due date: 25 Jun, 202625 Jun, 2026 4.00 Lacs
Tender For repair daf round with material etp vihar - ms plate (bottom & side wall), ms angle / channel, ms pipe (inlet / outlet corrosion, red pxide primer + enamel paint (outside).

Central Government/Public Sector

CTN :45532362 Due date: 03 Jul, 202603 Jul, 2026 45.00 Lacs
Tender For certain repair to water supply distribution lines and other connected items at mil stn bhuj and gandhidham under ge (a) bhuj - taking up u/s ci /di/ac water main (incl all fitting) with spigot & socket /ms pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 400 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and as directed., all as per item 1 above but 250 mm dia bore complete all as specified and as directed., all as per item 1 above but 200 mm dia bore complete all as specified and as directed., all as per item 1 above but 150 mm dia bore complete all as specified and as directed., all as per item 1 above but 100 mm dia bore complete all as specified and as directed., material and labour di pipes of size 400 mm bore with spigot and socket end centrifugally cast class "k- 9" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed., all as per item 6 above but 250 mm dia bore complete all as specified and as directed., all as per item 6 above but 200 mm dia bore complete all as specified and as directed., all as per item 6 above but 150 mm dia bore complete all as specified and as directed., all as per item 6 above but 100 mm dia bore complete all as specified and as directed., material and labour di pipes of size 200 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed., all as per item 11 above but 150 mm dia bore complete all as specified and as directed., all as per item 11 above but 100 mm dia bore complete all as specified and as directed., m&l di bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of the following size 250 upto 400 mm dia complete all as specified and as directed., all as per item 13 above but upto 80 to 200 mm bore complete all as specified and as directed., m&l for run laid laid joint for ci pipe of size 100 mm bore complete all as specified and as directed., m&l for run laid laid joint for ci pipe of size 150/200 mm bore complete all as specified and as directed., m&l for ruber gas ket joint/ tyton joint for ci / di pipe of size 250 to 400 mm bore complete all as specified and as directed., m&l for ruber gas ket joint/ tyton joint for ci / di pipe of size 80 to 200 mm bore complete all as specified and as directed., taking down carefully cast iron sluice valve of size 250 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 200 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 150 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 100 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass s
 Loading, Please wait...

Connect us via What's Up