Get complete information related to latest Angles Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Angles Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Angles Scrap Tenders.
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab
Tender For bid to ras tender for supply of fabrication and supply of luh 62 composite parts including painting- top fwd cover sub assem. lh , top fwd cover sub assem. rh , baggage bay panel sub assem. lh , baggage bay panel sub assem. rh , side shell top panel sub assem. lh , side shell top panel sub assem. rh , bottom aft cover sub assem. lh , bottom aft cover sub assem. rh , bot. longeron subassem. lh , bot. longeron subassem. rh , top aft cover sub assem. lh , top aft cover sub assem. rh , longeron assembly lhs , access cover sub assem. lh , access cover sub assem. rh , longeron assembly rhs , panel sub assem. 6 to 7 lh , panel sub assem. 6 to 7 rh , cover sub assem. 6 to 7 lh , cover sub assem. 6 to 7 rh , access panel 6 to 7 rhs , bottom bay panel between 6 & 7 rh , bottom bay panel between 6 & 7 lh , panel assem. x2765 to 3 rh , top bay panel between 5 and 6 lh , top bay panel between 5 and 6 rh , access panel sub assem rhs , access cover sub assem. , l angle assem x2765 to 3 lh , l angle assem x2765 to 3 rh , panel assem. x2765 to 3 lh , access panel sub assem. 2 to 3 l , access cover sub assembly 1 , mip support bracket , mip support bracket , clip assembly lh , clip assembly rh , equipment panel sub.assem.middle 8 , top longeron betw. 5 and 6 lh , top longeron betw. 5 and 6 rh , top center cover sub assem. at 7 , access panel sub assy , nose glass support structure lh , nose glass support structure rh , pump cover assembly 4 to 5 , collector box cover assembly , channel assembly lh , channel assembly rh , clip lh , clip rh , cover assembly , cover assembly lh , cover assembly rh , collector box sub assembly , vent box door lh , vent box door rh , forward fairing , aft fairing , center fairing top , center fairing bottom , longer step assembly skid , bottom shell sub assem. 2 to 3
Tender For supply of copper alloy taps/stop valves (v2) conforming to is 8931 (q3) , plastic bib taps, pillar taps, angle valves & stop valves for hot & cold water services conforming to is 9763 (q3) , bathroom water shower (v2) (q3) , waste fittings for washbasin and sinks as per is 2963 (q3) , plastic seats and covers for water - closets as per is 2548 (q3) , soap dish - case (q4) , flexible drain hoses for wash basins/ sinks (q3) , towel ring (q3) , stainless steel sinks for domestic purposes (v3) as per is 13983 (q2) , towel rail (q3) , water storage tank 500 ltrs , water storage tank 1000 ltrs , looking mirror 450 by 600mm with pvc frame , float valve brass 20mm complete with rod and ball , wire mesh ss 1 pt 2 m wide 15m long , cp paper roll , olive green paint , weather coat primer , black paint , flash strip self adhesive 100mm by 1mtr , curtain bracket decorative type , rubber gasket with almn body snake guard for door 1 mtr long , hydraulic door closer , brass peg set of six , cement ppc 50 kgs , ss curtain rod size 24 25mm 10 ft long , door handle aluminium 150 mm , self adhesive app membrane 3 mm thick , oil putty , pvc connection 15 by 450mm , sliding door bolt 300 mm aluminium , pvc swr tee 75mm , pvc float valve 25 mm bore incl balls , grating cp 125mm , tower bolt aluminium 150mm , floor drain tapes grating pvc 100mm , tank cover of 500 ltr , ms hinges 100mm , rubber washer for flushing cistern incl balls , hasp and staple 75mm , cpvc 20 by 15 inch brass socket , pvc connection 15 by 600mm , door stopper 100mm long , cpvc tank connector 25 mm , cpvc 25 by 20 inch fabt , elbow gi 15 mm isi marked , tower bolt almn 100 mm , cpvc fabt 25mm , tee reducer gi 20 mm to 15 mm isi marked , gi elbow 20 mm isi marked , helical door spring 200 mm , cpvc 25 by 20mm brass mabt , ms hinges 50mm , cpvc mabt 25mm , cpvc brass elbow 25mm , m seal , cpvc 20mm mabt , white cement , drill bit 6 mm , but hinges 75mm , oil bound distemper , cement based paint , cpvc fabt 20mm , gi tank nipple 25mm , cpvc 20 by 15mm brass mabt , brass spindle 15 mm for stop cock , taflon tape , brass spindle 15 mm for bib cock , glass shelf 600 mm , cpvc brass socket 20mm , aluminium door handle 100 mm , cpvc brass elbow 20 mm , cpvc elbow 20 mm bore , glass cutter , cpvc tank nipple 20mm , pvc connection pipe 900mm , urinal waste pipe 32mm , aluminium tower bolt 75mm , nails 3 inch , nails 2 inch , cpvc reducer socket 20 by 25 mm , nails 1 inch , hacksaw blade 2 pt 5mm thick , aluminium handle 75mm , cpvc socket 20mm , stop cock brass concealed 20 mm , tower bolt almn 200mm , cpvc brass tee 20 by 15 mm , cpvc gate valve 25 mm , cpvc gate valve 20 mm , pvc swr pipe 40 mm , pvc swr elbow 40 mm , pvc swr tee 40 mm , wash basin anchor fastener size 8 mm , wash basin anchor fastener size 10 mm , cpvc pipe 25 mm , cpvc pipe 20 mm , brass spindle for concealed stop cock length 3 inch , brass spindle for concealed stop cock length 2 pt 5 inch , brass spindle for concealed stop cock length 2 inch , brass spindle for concealed stop cock length 1 pt 5 inch , long bend pipe for flushing cistern //bid details 2 / 93