Get complete information related to latest Anti Climbing Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Anti Climbing Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Anti Climbing Device Tenders.
Tender For supplying installing commissioning solar fencing 4 lines 3.25 kms for the protection of 2026 sankarangode teak plantation in padukka fs of karulai range under nilambur south division during 2026-27
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anticlimbingdevices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarm system, fence alarm system covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser
Tender For provision, of anti-climbingdevices including supply and installation, in monkey prone areas to prevent climbing monkeys on ohe portals and masts in ratnagiri region of konkan railway.
Tender For corrigendum : repair/ renovation, face lifting, chain link fencing and solar lights for ziyarat hazrat syed hassan sheikh basri sahab (ra) tujan pulwama.(except solar lights)